Diagnostic accuracy of body coil MRI in describing the characteristics of perianal fistulas

被引:19
作者
Mahjoubi, B
Kharazi, HH
Mirzaei, R
Moghimi, A
Changizi, A
机构
[1] Iran Univ Med Sci & Hlth Care Serv, Dept Radiol, Tehran, Iran
[2] Iran Univ Med Sci & Hlth Care Serv, Dept Surg, Tehran, Iran
关键词
MRI; perianal fistula; diagnosis; characteristic;
D O I
10.1111/j.1463-1318.2005.00899.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective The purpose of this study was to determine the accuracy of synergic body coil MRI using SPIR technique without contrast, in the determination of fistula characteristics in patients with clinically positive signs. Method and subjects This was a case-series prospective study including 29 consecutive patients with clinically suspected fistulas-in-ano. The standard synergic body coil was used and all patients had T2-weighted SPIR sequences. One radiologist, without prior knowledge of the clinical examination, analysed images and noted the presence of the fistula, its classification and the presence and number of any collections or extensions. The surgeon noted the MRI findings and looked for lesions suggested on MRI. The results of the MRI and surgical assessments were then compared. Results of surgical exploration while the surgeon was aware of MRI results were considered as the gold standard of surgical anatomy. Results Twenty-three (79.31%) of 29 fistula tracks were seen on MRI which correctly determined the type of all fistulas. In the six cases where the fistula was not seen on MRI, five were low trans-sphincteric and one was rectovaginal. MRI identified 8 of 10 collections. Conclusion The synergic body coil MRI with SPIR sequencing without endoanal coils had a high accuracy in the diagnosis of high fistulas collections, complex fistulas and extensions.
引用
收藏
页码:202 / 207
页数:6
相关论文
共 23 条
[1]
MAGNETIC-RESONANCE-IMAGING OF FISTULA-IN-ANO - TECHNIQUE, INTERPRETATION AND ACCURACY [J].
BARKER, PG ;
LUNNISS, PJ ;
ARMSTRONG, P ;
REZNEK, RH ;
COTTAM, K ;
PHILLIPS, RK .
CLINICAL RADIOLOGY, 1994, 49 (01) :7-13
[2]
COMPARISON BETWEEN ANAL ENDOSONOGRAPHY AND DIGITAL EXAMINATION IN THE EVALUATION OF ANAL FISTULAS [J].
CHOEN, S ;
BURNETT, S ;
BARTRAM, CI ;
NICHOLLS, RJ .
BRITISH JOURNAL OF SURGERY, 1991, 78 (04) :445-447
[3]
D'Hoore A, 2000, ACTA CHIR BELG, V100, P111
[4]
FISTULAS IN ANO-ENDOANAL ULTRASONOGRAPHIC ASSESSMENT ASSISTS DECISION-MAKING FOR SURGERY [J].
DEEN, KI ;
WILLIAMS, JG ;
HUTCHINSON, R ;
KEIGHLEY, MRB ;
KUMAR, D .
GUT, 1994, 35 (03) :391-394
[5]
High resolution magnetic resonance imaging of the anal sphincter using a dedicated endoanal coil - Comparison of magnetic resonance imaging with surgical findings [J].
deSouza, NM ;
Hall, AS ;
Puni, R ;
Gilderdale, DJ ;
Young, IR ;
Kmiot, WA .
DISEASES OF THE COLON & RECTUM, 1996, 39 (08) :926-934
[6]
HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE ANAL-SPHINCTER USING AN INTERNAL COIL [J].
DESOUZA, NM ;
KMIOT, WA ;
PUNI, R ;
HALL, AS ;
BURL, M ;
BARTRAM, CI ;
BYDDER, GM .
GUT, 1995, 37 (02) :284-287
[7]
MRI of fistula-in-ano: A comparison of endoanal coil with external phased array coil techniques [J].
deSouza, NM ;
Gilderdale, DJ ;
Coutts, GA ;
Puni, R ;
Steiner, RE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (03) :357-363
[8]
PELVIC AND PERINEAL COMPLICATIONS OF CROHNS-DISEASE - ASSESSMENT USING MAGNETIC-RESONANCE-IMAGING [J].
HAGGETT, PJ ;
MOORE, NR ;
SHEARMAN, JD ;
TRAVIS, SPL ;
JEWELL, DP ;
MORTENSEN, NJ .
GUT, 1995, 36 (03) :407-410
[9]
MR imaging of fistula in ano: Are endoanal coils the gold standard? [J].
Halligan, S ;
Bartram, CI .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) :407-412
[10]
Magnetic resonance imaging of fistula-in-ano: STIR or SPIR? [J].
Halligan, S ;
Healy, JC ;
Bartram, CI .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (842) :141-145