Fabrication of SU-8 based microchip electrophoresis with integrated electrochemical detection for neurotransmitters

被引:25
作者
Castano-Alvarez, Mario [1 ]
Teresa Fernandez-Abedul, M. [1 ]
Costa-Garcia, Agustin [1 ]
Agirregabiria, Maria [2 ]
Fernandez, Luis J. [2 ]
Miguel Ruano-Lopez, Jesus [2 ]
Barredo-Presa, Borja [3 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Asturias, Spain
[2] IKERLAN IK4 S Coop, MEMS MST Dept, Arrasate Mondragon, Spain
[3] Microliquid Experts Microfluid, Arrasate Mondragon, Spain
关键词
Microchip electrophoresis; Photoresist EPON SU-8; Electrochemical detection; End-channel detector; Platinum thin-film; Neurotransmitters; CAPILLARY-ELECTROPHORESIS; AMPEROMETRIC DETECTION; MICROFLUIDIC CHANNELS; FILM DECOUPLER; SEPARATION; CHIPS; PERFORMANCE; ELECTRODE; DOPAMINE; POLY(METHYLMETHACRYLATE);
D O I
10.1016/j.talanta.2009.05.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new SU-8 based microchip capillary electrophoresis (MCE) device has been developed for the first time with integrated electrochemical detection. Embedded electrophoretic microchannels have been fabricated with a multilayer technology based on bonding and releasing steps of stacked SU-8 films. This technology has allowed the monolithic integration in the device of the electrochemical detection system based on platinum electrodes. The fabrication of the chips presented in this work is totally compatible with reel-to-reel techniques, which guarantee a low cost and high reliability production. The influence of relevant experimental variables, such as the separation voltage and detection potential, has been studied on the SU-8 microchip with an attractive analytical performance. Thus, the effective electrical isolation of the end-channel amperometric detector has been also demonstrated. The good performance of the SU-8 device has been proven for separation and detection of the neurotransmitters, dopamine (DA) and epinephrine (EP). High efficiency (30,000-80,000 N/m), excellent precision, good detection limit (450 nM) and resolution (0.90-1.30) has been achieved on the SU-8 microchip. These SU-8 devices have shown a better performance than commercial Topas (thermoplastic olefin polymer of amorphous structure) microchips. The low cost and versatile SU-8 microchip with integrated platinum film electrochemical detector holds great promise for high-volume production of disposable microfluidic analytical devices. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 56 条
[1]   Fabrication of SU-8 multilayer microstructures based on successive CMOS compatible adhesive bonding and releasing steps [J].
Agirregabiria, M ;
Blanco, FJ ;
Berganzo, J ;
Arroyo, MT ;
Fullaondo, A ;
Mayora, K ;
Ruano-López, JM .
LAB ON A CHIP, 2005, 5 (05) :545-552
[2]   SDS-CGE of proteins in microchannels made of SU-8 films [J].
Agirregabiria, Maria ;
Blanco, Francisco Javier ;
Berganzo, Javier ;
Fullaondo, Asier ;
Zubiaga, Ana Maria ;
Mayora, Kepa ;
Ruano-Lopez, Jesus M. .
ELECTROPHORESIS, 2006, 27 (18) :3627-3634
[3]   Polyelectrolyte-modified short microchannel for cation separation [J].
Bai, XX ;
Roussel, C ;
Jensen, H ;
Girault, HH .
ELECTROPHORESIS, 2004, 25 (06) :931-935
[4]   Fully integrated on-chip electrochemical detection for capillary electrophoresis in a microfabricated device [J].
Baldwin, RP ;
Roussel, TJ ;
Crain, MM ;
Bathlagunda, V ;
Jackson, DJ ;
Gullapalli, J ;
Conklin, JA ;
Pai, R ;
Naber, JF ;
Walsh, KM ;
Keynton, RS .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3690-3697
[5]   Novel three-dimensional embedded SU-8 microchannels fabricated using a low temperature full wafer adhesive bonding [J].
Blanco, FJ ;
Agirregabiria, M ;
Garcia, J ;
Berganzo, J ;
Tijero, M ;
Arroyo, MT ;
Ruano, JM ;
Aramburu, I ;
Mayora, K .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (07) :1047-1056
[6]   Amperometric detector designs for capillary electrophoresis microchips [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1109 (02) :291-299
[7]   Poly(methylmethacrylate) and Topas capillary electrophoresis microchip performance with electrochemical detection [J].
Castaño-Alvarez, M ;
Fernández-Abedul, MT ;
Costa-García, A .
ELECTROPHORESIS, 2005, 26 (16) :3160-3168
[8]   Electroactive intercalators for DNA analysis on microchip electrophoresis [J].
Castano-Alvarez, Mario ;
Teresa Fernandez-Abedul, M. ;
Costa-Garcia, Agustin .
ELECTROPHORESIS, 2007, 28 (24) :4679-4689
[9]   Analytical performance of CE microchips with amperometric detection [J].
Castano-Alvarez, Mario ;
Fernandez-Abedul, M. Teresa ;
Costa-Garcia, Agustin .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2006, 34 (06) :697-710
[10]   Palladium film decoupler for amperometric detection in electrophoresis chips [J].
Chen, DC ;
Hsu, FL ;
Zhan, DZ ;
Chen, CH .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :758-762