Detection of fast capillary electrophoresis peptide and protein separations using electrospray ionization with a time-of-flight mass spectrometer

被引:71
作者
Banks, JF
Dresch, T
机构
[1] Analytica of Branford, Branford, CT 06405
关键词
D O I
10.1021/ac9509824
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fast capillary electrophoresis (CE) separations on bare and coated fused silica have been detected on-line using a time-of-flight mass spectrometer which is capable of acquiring spectra at a rate suitable for the narrow peaks generated by CE. Protein and peptide separations producing peaks 1-2 s in width have been detected with an integration time of 0.125 s/spectrum, each spectrum being the sum of 1024 complete m/z range scans. The effects of the liquid sheath now rate, electric field strength, and integration time on sensitivity and peak shape have been examined. A sensitivity limit of 8 fmol has been established for leucine enkephalin.
引用
收藏
页码:1480 / 1485
页数:6
相关论文
共 40 条
  • [11] LIQUID SHEATH EFFECTS ON THE SEPARATION OF PROTEINS IN CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY
    FORET, F
    THOMPSON, TJ
    VOUROS, P
    KARGER, BL
    GEBAUER, P
    BOCEK, P
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (24) : 4450 - 4458
  • [12] CAPILLARY ELECTROPHORESIS FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY WITH SUSTAINED OFF-RESONANCE IRRADIATION FOR THE CHARACTERIZATION OF PROTEIN AND PEPTIDE MIXTURES
    HOFSTADLER, SA
    WAHL, JH
    BAKHTIAR, R
    ANDERSON, GA
    BRUCE, JE
    SMITH, RD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (10) : 894 - 899
  • [13] ZONE ELECTROPHORESIS IN OPEN-TUBULAR GLASS-CAPILLARIES
    JORGENSON, JW
    LUKACS, KD
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (08) : 1298 - 1302
  • [14] LIQUID JUNCTION COUPLING FOR CAPILLARY ZONE ELECTROPHORESIS ION SPRAY MASS-SPECTROMETRY
    LEE, ED
    MUCK, W
    HENION, JD
    COVEY, TR
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1989, 18 (09): : 844 - 850
  • [15] ONLINE CAPILLARY ZONE ELECTROPHORESIS ION SPRAY TANDEM MASS-SPECTROMETRY FOR THE DETERMINATION OF DYNORPHINS
    LEE, ED
    MUCK, W
    HENION, JD
    COVEY, TR
    [J]. JOURNAL OF CHROMATOGRAPHY, 1988, 458 : 313 - 321
  • [16] CAPILLARY ZONE ELECTROPHORESIS TANDEM MASS-SPECTROMETRY FOR THE DETERMINATION OF SULFONATED AZO DYES
    LEE, ED
    MUCK, W
    HENION, JD
    COVEY, TR
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1989, 18 (04): : 253 - 257
  • [17] TANDEM MASS-SPECTROMETRY OF VERY LARGE MOLECULES .2. DISSOCIATION OF MULTIPLY CHARGED PROLINE-CONTAINING PROTEINS FROM ELECTROSPRAY IONIZATION
    LOO, JA
    EDMONDS, CG
    SMITH, RD
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (04) : 425 - 438
  • [18] TANDEM MASS-SPECTROMETRY OF SMALL, MULTIPLY CHARGED OLIGONUCLEOTIDES
    MCLUCKEY, SA
    VANBERKEL, GJ
    GLISH, GL
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (01) : 60 - 70
  • [19] DETECTION OF ELECTROSPRAY-IONIZATION USING A QUADRUPOLE ION-TRAP STORAGE REFLECTRON TIME-OF-FLIGHT MASS-SPECTROMETER
    MICHAEL, SM
    CHIEN, BM
    LUBMAN, DM
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (19) : 2614 - 2620
  • [20] ELECTROSPRAY-IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY IN PROTEIN CHEMISTRY
    MIRGORODSKAYA, OA
    SHEVCHENKO, AA
    CHERNUSHEVICH, IV
    DODONOV, AF
    MIROSHNIKOV, AI
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (01) : 99 - 107