Development of amperometric lysine biosensors based on Au nanoparticles/multiwalled carbon nanotubes/polymers modified Au electrodes

被引:34
作者
Chauhan, Nidhi [1 ]
Singh, Anamika [2 ]
Narang, Jagriti [1 ]
Dahiya, Swati [2 ]
Pundir, C. S. [1 ]
机构
[1] Maharshi Dayanand Univ, Dept Biochem, Rohtak 124001, Haryana, India
[2] Kurukshetra Univ, UIET, Dept Biotechnol, Kurukshetra 136119, Haryana, India
关键词
CHROMATOGRAPHIC DETERMINATION; OXIDASE; GLUCOSE; GLUTAMATE; FEEDS;
D O I
10.1039/c2an35629e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of two amperometric L-lysine biosensors is described in this study. The construction comprises the covalent immobilization of lysine oxidase (LOx) onto nanocomposite composed of gold nanoparticles (AuNPs) and carboxylated multiwalled carbon nanotubes (c-MWCNT), decorated on (i) polyaniline (PANI) and (ii) poly 1,2 diaminobenzene (DAB), electrodeposited on Au electrodes. The biosensors were characterized by scanning electron microscopy (SEM), Fourier transform infrared (FTIR) and electrochemical impedance spectroscopy (EIS) studies. The optimum response (current) was observed within 2 s at pH 7.0 and 25 degrees C for LOx/AuNPs/c-MWCNT/PANI/Au, and 4 s at pH 7.0 and 30 degrees C for LOx/AuNPs/c-MWCNT/DAB/Au electrodes. There was a linear relationship between current and lysine concentration ranging from 5.0 to 600 mu M for LOx/AuNPs/c-MWCNT/PANI/Au with a detection limit of 5.0 mu M, and 20 to 600 mu M for the LOx/AuNPs/c-MWCNT/DAB/Au electrode with a detection limit of 20 mu M. The PANI modified electrode was in good agreement with the standard HPLC method, with a better correlation (r = 0.992) compared to the DAB modified electrode (r = 0.986). These observations revealed that the PANI modified Au electrode was better than the DAB modified electrode, and hence it was employed for the determination of lysine in milk, pharmaceutical tablets and sera. The PANI modified electrode showed a half life of 120 days, compared to that of 90 days for the DAB modified electrode, after their 100 uses, when stored at 4 degrees C.
引用
收藏
页码:5113 / 5122
页数:10
相关论文
共 22 条
[1]   Flow injection amperometric and chemiluminescence individual and simultaneous determination of lysine and glucose with immobilized lysine oxidase and glucose oxidase [J].
Almuaibed, AM ;
Townshend, A .
ANALYTICA CHIMICA ACTA, 1997, 338 (1-2) :149-154
[2]  
Anastassiadis Savas, 2007, Recent Pat Biotechnol, V1, P11, DOI 10.2174/187220807779813947
[3]   Studies of the binding and signaling of surface-immobilized periplasmic glucose receptors on gold nanoparticles: A glucose biosensor application [J].
Andreescu, Silvana ;
Luck, Linda A. .
ANALYTICAL BIOCHEMISTRY, 2008, 375 (02) :282-290
[4]   Fabrication of multiwalled carbon nanotubes/polyaniline modified Au electrode for ascorbic acid determination [J].
Chauhan, Nidhi ;
Narang, Jagriti ;
Pundir, C. S. .
ANALYST, 2011, 136 (09) :1938-1945
[5]   A new interference-free lysine biosensor using a non-conducting polymer film [J].
Curulli, A ;
Kelly, S ;
O'Sullivan, C ;
Guilbault, GG ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (12) :1245-1250
[6]   Quantitative detection of crystalline lysine supplementation in poultry feeds using a rapid bacterial bioluminescence assay [J].
Díaz, IB ;
Ricke, SC .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2003, 62 (2-3) :268-273
[7]   Flow injection differential potentiometric determination of lysine by using a lysine biosensor [J].
García-Villar, N ;
Saurina, J ;
Hernández-Cassou, S .
ANALYTICA CHIMICA ACTA, 2003, 477 (02) :315-324
[8]   The kinetic and analytical behaviours of an L-lysine amperometric biosensor based on lysine oxidase immobilised onto a platinum electrode by co-crosslinking [J].
Guerrieri, Antonio ;
Cataldi, Tornmaso R. I. ;
Ciriello, Rosanna .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 126 (02) :424-430
[9]   Construction of a L-lysine biosensor by immobilizing lysine oxidase on a gold-poly(o-phenylenediamine) electrode [J].
Karalemas, ID ;
Georgiou, CA ;
Papastathopoulos, DS .
TALANTA, 2000, 53 (02) :391-402
[10]   Development of an interferent free amperometric biosensor for determination of L-lysine in food [J].
Kelly, SC ;
O'Connell, PJ ;
O'Sullivan, CK ;
Guilbault, GG .
ANALYTICA CHIMICA ACTA, 2000, 412 (1-2) :111-119