Development of an interferent free amperometric biosensor for determination of L-lysine in food

被引:47
作者
Kelly, SC [1 ]
O'Connell, PJ [1 ]
O'Sullivan, CK [1 ]
Guilbault, GG [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Lab Sensor Dev, Cork, Ireland
关键词
L-lysine; L-ornithine; ruthenium; rhodium; amperometric biosensor;
D O I
10.1016/S0003-2670(00)00767-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly selective, fast responding amperometric biosensor is described, useful for the determination of L-lysine in food. Common electrochemical interferences, like acetoaminophen and ascorbic acid have zero response at +100 mV applied onto a ruthenium/rhodium coated glassy carbon electrode covered with 1,2-diaminobenzene polymer. This novel transducer was coupled with L-lysine alpha-oxidase purified from Trichoderma viride and at the appropriate pH, classic substrate interferences from L-ornithine, L-arginine and L-phenylalanine are reduced to 3.4, 1.1 and 0.7% of the response to L-lysine (taken as 100%). No other amino acids respond. The sensor is inexpensive to produce, has excellent repeatability and very good reproducibility. Thus, the L-lysine (protein) content of foods can be almost specifically determined following rapid microwave digestion of the product. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 29 条
[1]   Flow injection amperometric and chemiluminescence individual and simultaneous determination of lysine and glucose with immobilized lysine oxidase and glucose oxidase [J].
Almuaibed, AM ;
Townshend, A .
ANALYTICA CHIMICA ACTA, 1997, 338 (1-2) :149-154
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .1. THEORY [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :27-35
[3]   Selective biosensing of L-lysine by a low-temperature flow-injection technique using an immobilized lysine oxidase reactor [J].
Chen, RLC ;
Lee, MH ;
Matsumoto, K .
ANALYTICAL SCIENCES, 1996, 12 (01) :87-90
[4]   A new interference-free lysine biosensor using a non-conducting polymer film [J].
Curulli, A ;
Kelly, S ;
O'Sullivan, C ;
Guilbault, GG ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (12) :1245-1250
[5]   A LYSINE DEHYDROGENASE-BASED ELECTRODE FOR BIOSENSING OF L-LYSINE [J].
DEMPSEY, E ;
WANG, J ;
WOLLENBERGER, U ;
OZSOZ, M ;
SMYTH, MR .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (05) :323-327
[6]   USE OF POLYMER-FILMS IN AMPEROMETRIC BIOSENSORS [J].
EMR, SA ;
YACYNYCH, AM .
ELECTROANALYSIS, 1995, 7 (10) :913-923
[7]  
FERNANDEZTRAPIELLA AC, 1990, J ASSOC OFF ANA CHEM, V73, P935
[8]  
HURRELL RF, 1981, PROG FOOD NUTR SCI, V5, P159
[9]   ORTHO-PHTHALDIALDEHYDE PRECOLUMN DERIVATIZATION AND REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF POLYPEPTIDE HYDROLYSATES AND PHYSIOLOGICAL FLUIDS [J].
JONES, BN ;
GILLIGAN, JP .
JOURNAL OF CHROMATOGRAPHY, 1983, 266 (AUG) :471-482
[10]  
KUSAKABE H, 1980, J BIOL CHEM, V255, P976