Portal imaging based definition of the planning target volume during pelvic irradiation for gynecological malignancies

被引:15
作者
Mock, U [1 ]
Dieckmann, K [1 ]
Wolff, U [1 ]
Knocke, TH [1 ]
Pötter, R [1 ]
机构
[1] Univ Hosp Vienna, Dept Radiotherapy & Radiolbiol, A-1090 Vienna, Austria
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 45卷 / 01期
关键词
portal imaging; gynecological malignancies; radiation therapy;
D O I
10.1016/S0360-3016(99)00140-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Geometrical accuracy in patient positioning can vary substantially during external radiotherapy. This study estimated the set-up accuracy during pelvic irradiation for gynecological malignancies for determination of safety margins (planning target volume, PTV), Methods and Materials: Based on electronic portal imaging devices (EPID), 25 patients undergoing 4-field pelvic irradiation for gynecological malignancies were analyzed with regard to set-up accuracy during the treatment course. Regularly performed EPID images were used in order to systematically assess the systematic and random component of set-up displacements. Anatomical matching of verification and simulation images was followed by measuring corresponding distances between the central axis and anatomical features. Data analysis of set-up errors referred to the x-, y-,and z-axes. Additionally, cumulative frequencies were evaluated, Results: A total of 50 simulation films and 313 verification images were analyzed. For the anterior-posterior (AP) beam direction mean deviations along the x- and z-axes were 1.5 mm and -1.9 mm, respectively, Moreover, random errors of 4.8 mm (x-asis) and 3.0 mm (z-axis) were determined, Concerning the latero-lateral treatment fields, the systematic errors along the two axes were calculated to 2.9 mm (y-axis) and -2.0 mm (z-axis) and random errors of 3.8 mm and 3.5 mm were found, respectively, The cumulative frequency of misalignments less than or equal to 5 mm showed values of 75 % (AP fields) and 72 % (latero-lateral fields). With regard to cumulative frequencies less than or equal to 10 mm quantification revealed values of 97 % for both beam directions. Conclusion: During external pelvic irradiation therapy for gynecological malignancies, EPID images on a regular basis revealed acceptable set-up inaccuracies. Safety margins (PTV) of 1 cm appear to be sufficient, accounting for more than 95% of all deviations. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:227 / 232
页数:6
相关论文
共 25 条
[11]   QUALITY-CONTROL OF RADIOTHERAPY DURING PELVIC IRRADIATION [J].
GRIFFITHS, SE ;
KHOURY, GG ;
EDDY, A .
RADIOTHERAPY AND ONCOLOGY, 1991, 20 (03) :203-206
[12]   Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate [J].
Hanley, J ;
Lumley, MA ;
Mageras, GS ;
Sun, J ;
Zelefsky, MJ ;
Leibel, SA ;
Fuks, Z ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02) :435-444
[13]   ACCURACY IN RADIATION-FIELD ALIGNMENT IN HEAD AND NECK-CANCER - A PROSPECTIVE-STUDY [J].
HUIZENGA, H ;
LEVENDAG, PC ;
DEPORRE, PMZR ;
VISSER, AG .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (02) :181-187
[14]  
KINZIE JJ, 1983, CANCER, V52, P2223, DOI 10.1002/1097-0142(19831215)52:12<2223::AID-CNCR2820521209>3.0.CO
[15]  
2-D
[16]   THE ROYAL-MARSDEN-HOSPITAL PELVIC RADIOTHERAPY TRIAL - TECHNICAL ASPECTS AND QUALITY ASSURANCE [J].
MAYLES, WPM ;
CHOW, M ;
DYER, J ;
FERNANDEZ, EM ;
HEISIG, S ;
KNIGHT, RT ;
MOORE, I ;
NAHUM, AE ;
SHENTALL, GS ;
TAIT, DM .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :184-191
[17]   Prospective clinical evaluation of an electronic portal imaging device [J].
Michalski, JM ;
Graham, MV ;
Bosch, WR ;
Wong, J ;
Gerber, RL ;
Cheng, A ;
Tinger, A ;
Valicenti, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (04) :943-951
[18]   IS IT NECESSARY TO REPEAT QUALITY-CONTROL PROCEDURES FOR HEAD AND NECK PATIENTS [J].
MITINE, C ;
LEUNENS, G ;
VERSTRAETE, J ;
BLANCKAERT, N ;
VANDAM, J ;
DUTREIX, A ;
VANDERSCHUEREN, E .
RADIOTHERAPY AND ONCOLOGY, 1991, 21 (03) :201-210
[19]  
POTTER R, 1989, THESIS MUNSTER
[20]   ACCURACY OF RADIATION-FIELD ALIGNMENT IN CLINICAL-PRACTICE [J].
RABINOWITZ, I ;
BROOMBERG, J ;
GOITEIN, M ;
MCCARTHY, K ;
LEONG, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (10) :1857-1867