Echocardiographic Measures of Myocardial Deformation by Speckle-Tracking Technologies: The Need for Standardization?

被引:63
作者
Nelson, Matthew R. [1 ]
Hurst, R. Todd [1 ]
Raslan, Serageldin F. [1 ]
Cha, Stephen [2 ]
Wilansky, Susan [1 ]
Lester, Steven J. [1 ]
机构
[1] Mayo Clin Scottsdale, Div Cardiovasc Dis, Scottsdale, AZ 85259 USA
[2] Mayo Clin, Div Biomed Stat & Informat, Rochester, MN USA
关键词
Speckle-tracking; Strain; Echocardiography; STRAIN; SOFTWARE;
D O I
10.1016/j.echo.2012.08.006
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background: Multiple vendor-specific two-dimensional speckle-tracking echocardiographic algorithms with which to characterize myocardial mechanics are commercially available. The purpose of this study was to compare global longitudinal strain (GLS) results between two independent software vendors using a neutral image platform. Methods: A convenience sample of 100 prospectively collected patients was evaluated. Subjects with more than two left ventricular endocardial segments poorly delineated were excluded. GLS was obtained from the apical four-chamber, three-chamber, and two-chamber views using two independent speckle-tracking echocardiographic software packages (EchoInsight version 1.5.0 and Image-Arena version 4.5). Linear regression analysis and paired t tests were used to compare GLS results. Intraclass correlation coefficients and Bland-Altman plots were used for assessments of reliability. Results: The "out-of-the-box" mean GLS was -12.99 +/- 2.38% using EchoInsight and -16.87 +/- 2.84% using Image-Arena (mean difference, 3.876 +/- 2.42%; P = .0001). Agreement between the software packages was moderate (intraclass correlation coefficient, 0.43; 95% confidence interval, 0.32-0.55). Using uniform variables to derive GLS (Lagrangian strain measured in systole and diastole at the endocardium and averaging the peak segmental strain curves), EchoInsight GLS was -16.17 +/- 2.90% and Image-Arena GLS was -16.87 +/- 2.84% (mean difference, 0.70 +/- 2.75%; P = .02), with an intraclass correlation coefficient of 0.70 (95% confidence interval, 0.52-0.79). Conclusions: Image-Arena GLS results were consistently different (more negative) than EchoInsight measures out of the box but became similar when information used to derive GLS was uniform. The evolution of measures of myocardial mechanics into routine clinical practice will require vigilance and standardization of the various techniques, necessitating independent validation of commercially available speckle-tracking echocardiographic products. (J Am Soc Echocardiogr 2012;25:1189-94.)
引用
收藏
页码:1189 / 1194
页数:6
相关论文
共 13 条
[1]
Feasibility and Accuracy of Different Techniques of Two-Dimensional Speckle Based Strain and Validation With Harmonic Phase Magnetic Resonance Imaging [J].
Bansal, Manish ;
Cho, Goo-Yeong ;
Chan, Jonathan ;
Leano, Rodel ;
Haluska, Brian A. ;
Marwick, Thomas H. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (12) :1318-1325
[2]
Comparison of Two Different Speckle Tracking Software Systems: Does the Method Matter? [J].
Biaggi, Patric ;
Carasso, Shemy ;
Garceau, Patrick ;
Greutmann, Matthias ;
Gruner, Christiane ;
Tsang, Wendy ;
Rakowski, Harry ;
Agmon, Yoram ;
Woo, Anna .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (05) :539-547
[3]
A NOVEL METHOD FOR ANGLE INDEPENDENT ULTRASONIC-IMAGING OF BLOOD-FLOW AND TISSUE MOTION [J].
BOHS, LN ;
TRAHEY, GE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) :280-286
[4]
Velocity Vector Imaging: Standard Tissue-Tracking Results Acquired in Normals-The VVI-STRAIN Study [J].
Carasso, Shemy ;
Biaggi, Patric ;
Rakowski, Harry ;
Mutlak, Diab ;
Lessick, Jonathan ;
Aronson, Doron ;
Woo, Anna ;
Agmon, Yoram .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (05) :543-552
[5]
D'hooge J, 2000, Eur J Echocardiogr, V1, P154, DOI 10.1053/euje.2000.0031
[6]
Reproducibility and Inter-Vendor Variability of Left Ventricular Deformation Measurements by Three-Dimensional Speckle-Tracking Echocardiography [J].
Gayat, Etienne ;
Ahmad, Homaa ;
Weinert, Lynn ;
Lang, Roberto M. ;
Mor-Avi, Victor .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (08) :878-885
[7]
Hung MJ, INT J CARDI IN PRESS
[8]
Assessment of Myocardial Deformation in Children Using Digital Imaging and Communications in Medicine (DICOM) Data and Vendor Independent Speckle Tracking Software [J].
Koopman, Laurens P. ;
Slorach, Cameron ;
Manlhiot, Cedric ;
McCrindle, Brian W. ;
Jaeggi, Edgar T. ;
Mertens, Luc ;
Friedberg, Mark K. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (01) :37-44
[9]
Comparison between Different Speckle Tracking and Color Tissue Doppler Techniques to Measure Global and Regional Myocardial Deformation in Children [J].
Koopman, Laurens P. ;
Slorach, Cameron ;
Hui, Wei ;
Manlhiot, Cedric ;
McCrindle, Brian W. ;
Friedberg, Mark K. ;
Jaeggi, Edgar T. ;
Mertens, Luc .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (09) :919-928
[10]
Assessment of left ventricular function by different speckle-tracking software [J].
Manovel, Ana ;
Dawson, David ;
Smith, Benjamin ;
Nihoyannopoulos, Petros .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (05) :417-421