Comparison between Different Speckle Tracking and Color Tissue Doppler Techniques to Measure Global and Regional Myocardial Deformation in Children

被引:144
作者
Koopman, Laurens P. [1 ,3 ]
Slorach, Cameron [1 ]
Hui, Wei [1 ]
Manlhiot, Cedric [1 ]
McCrindle, Brian W. [1 ]
Friedberg, Mark K. [1 ]
Jaeggi, Edgar T. [1 ,2 ]
Mertens, Luc [1 ,2 ]
机构
[1] Univ Toronto, Hosp Sick Children, Labatt Family Heart Ctr, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Hosp Sick Children, Res Inst, Toronto, ON M5G 1X8, Canada
[3] Erasmus MC, Dept Pediat Cardiol, Rotterdam, Netherlands
关键词
Myocardial deformation; Speckle tracking; Color Doppler tissue imaging; Children; LEFT-VENTRICULAR FUNCTION; STRAIN-RATE; MAGNETIC-RESONANCE; 2-DIMENSIONAL SPECKLE; LONGITUDINAL STRAIN; HEALTHY-CHILDREN; ECHOCARDIOGRAPHY; VALIDATION; QUANTIFICATION; TETRALOGY;
D O I
10.1016/j.echo.2010.06.014
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background: Myocardial deformation parameters obtained by speckle-tracking echocardiography (STE) and color Doppler tissue imaging (CDTI) using two different ultrasound systems and three different software packages were compared. Methods: Apical four-chamber, short-axis grayscale, and color Doppler tissue images were prospectively acquired using Vivid 7 and iE33 ultrasound systems in 34 children and then analyzed using EchoPAC and QLAB (STE) and SPEQLE (CDTI). Results: Measurement of myocardial deformation was feasible for all three modalities. Longitudinal strain (epsilon) measurements showed the lowest intraobserver and interobserver variability (intraobserver and interobserver coefficients of variation, 9% and 8% for EchoPAC, 5% and 6% for QLAB, and 14% and 16% for SPEQLE). In addition, longitudinal epsilon had a small bias and narrow limits of agreement when comparing different techniques. The coefficients of variation of circumferential epsilon by EchoPAC and QLAB were 12% and 11% (intraobserver) and 9% and 13% (interobserver), respectively. Circumferential epsilon by STE had a small systematic bias but relatively narrow limits of agreement. The reproducibility of radial epsilon measurements using STE was low, while CDTI epsilon provided better performance (intraobserver and interobserver coefficients of variation for radial posterior epsilon, 12% and 24% for EchoPAC, 39% and 56% for QLAB, and 12% and 14% for SPEQLE). Radial epsilon was on average 50% lower using QLAB compared with EchoPAC and SPEQLE. Systolic strain rate values obtained by STE were lower compared with CDTI-derived values. The limits of agreement for strain rate values among the three modalities were wide, and intraobserver and interobserver variability was poor for all three modalities. Conclusions: Some deformation measurements (e.g., longitudinal and circumferential epsilon) are comparable among different ultrasound machines and software packages, whereas others are significantly different (e.g., radial epsilon and strain rate). This study stresses the need for an industry standard for these techniques. (J Am Soc Echocardiogr 2010;23:919-28.)
引用
收藏
页码:919 / 928
页数:10
相关论文
共 31 条
[1]
Noninvasive myocardial strain measurement by speckle tracking echocardiography - Validation against sonomicrometry and tagged magnetic resonance imaging [J].
Amundsen, BH ;
Helle-Valle, T ;
Edvardsen, T ;
Torp, H ;
Crosby, J ;
Lyseggen, E ;
Stoylen, A ;
Ihlen, H ;
Lima, JAC ;
Smiseth, OA ;
Slordahl, SA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) :789-793
[2]
Regional myocardial long-axis strain and strain rate measured by different tissue Doppler and speckle tracking echocardiography methods: a comparison with tagged magnetic resonance imaging [J].
Amundsen, Brage H. ;
Crosby, Jonas ;
Steen, Per Arvid ;
Torp, Hans ;
Slordahl, Stig A. ;
Stoylen, Asbjorn .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (02) :229-237
[3]
Feasibility and Accuracy of Different Techniques of Two-Dimensional Speckle Based Strain and Validation With Harmonic Phase Magnetic Resonance Imaging [J].
Bansal, Manish ;
Cho, Goo-Yeong ;
Chan, Jonathan ;
Leano, Rodel ;
Haluska, Brian A. ;
Marwick, Thomas H. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (12) :1318-1325
[4]
Analysis of myocardial deformation based on pixel tracking in two dimensional echocardiographic images enables quantitative assessment of regional left ventricular function [J].
Becker, M. ;
Bilke, E. ;
Kuehl, H. ;
Katoh, M. ;
Kramann, R. ;
Franke, A. ;
Buecker, A. ;
Hanrath, P. ;
Hoffmann, R. .
HEART, 2006, 92 (08) :1102-1108
[5]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]
Heart rate effects on strain and strain rate in healthy children [J].
Boettler, P ;
Hartmann, M ;
Watzl, K ;
Maroula, E ;
Schulte-Moenting, J ;
Knirsch, W ;
Dittrich, S ;
Kececioglu, D .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (11) :1121-1130
[7]
A NOVEL METHOD FOR ANGLE INDEPENDENT ULTRASONIC-IMAGING OF BLOOD-FLOW AND TISSUE MOTION [J].
BOHS, LN ;
TRAHEY, GE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (03) :280-286
[8]
Comparison of two-dimensional speckle and tissue velocity based strain and validation with harmonic phase magnetic resonance imaging [J].
Cho, Goo-Yeong ;
Chan, Jonathan ;
Leano, Rodel ;
Strudwick, Mark ;
Marwick, Thomas H. .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (11) :1661-1666
[9]
D'hooge J, 2000, Eur J Echocardiogr, V1, P154, DOI 10.1053/euje.2000.0031
[10]
Assessment of subendocardial vs. subepicardial left ventricular rotation and twist using two-dimensional speckle tracking echocardiography: comparison with tagged cardiac magnetic resonance [J].
Goffinet, Celine ;
Chenot, Fabien ;
Robert, Annie ;
Pouleur, Anne-Catherine ;
de Waroux, Jean-Benoit le Polain ;
Vancrayenest, David ;
Gerard, Olivier ;
Pasquet, Agnes ;
Gerber, Bernhard L. ;
Vanoverschelde, Jean-Louis .
EUROPEAN HEART JOURNAL, 2009, 30 (05) :608-617