Correction method and software for image distortion and nonuniform response in charge-coupled device-based X-ray detectors utilizing X-ray image intensifier

被引:41
作者
Ito, K
Kamikubo, H
Yagi, N
Amemiya, Y
机构
[1] Grad Univ Adv Studies, Dept Synchrotron Radiat Sci, Sch Math & Phys Sci, Tsukuba, Ibaraki 3050801, Japan
[2] Nara Adv Inst Sci & Technol, Dept Mat Sci, Nara 6300101, Japan
[3] JASRI, Sayo, Hyogo 6795198, Japan
[4] Univ Tokyo, Dept Adv Mat Sci, Grad Sch Frontier Sci, Kashiwa, Chiba 2778561, Japan
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS | 2005年 / 44卷 / 12期
基金
英国医学研究理事会;
关键词
X-ray detector; image distortion; nonuniform response; contrast reduction; small-angle X-ray scattering (SAXS); charge-coupled device (CCD); X-ray image intensifier;
D O I
10.1143/JJAP.44.8684
中图分类号
O59 [应用物理学];
学科分类号
摘要
An on-site method of correcting the image distortion and nonuniform response of a charge-coupled device (CCD)-based X-ray detector was developed using the response of the imaging plate as a reference. The CCD-based X-ray detector consists of a beryllium-windowed X-ray image intensifier (Be-XRII) and a CCD as the image sensor. An image distortion of 29% was improved to less than 1% after the correction. In the correction of nonuniform response due to image distortion, subpixel approximation was performed for the redistribution of pixel values. The optimal number of subpixels was also discussed. In an experiment with polystyrene (PS) latex, it was verified that the correction of both image distortion and nonuniform response worked properly. The correction for the "contrast reduction" problem was also demonstrated for an isotropic X-ray scattering pattern from the PS latex.
引用
收藏
页码:8684 / 8691
页数:8
相关论文
共 25 条
[1]   Activation mechanisms of transcriptional regulator CooA revealed by small-angle X-ray scattering [J].
Akiyama, S ;
Fujisawa, T ;
Ishimori, K ;
Morishima, I ;
Aon, S .
JOURNAL OF MOLECULAR BIOLOGY, 2004, 341 (03) :651-668
[2]   LARGE-APERTURE TV DETECTOR WITH A BERYLLIUM-WINDOWED IMAGE INTENSIFIER FOR X-RAY-DIFFRACTION [J].
AMEMIYA, Y ;
ITO, K ;
YAGI, N ;
ASANO, Y ;
WAKABAYASHI, K ;
UEKI, T ;
ENDO, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :2290-2294
[3]   IMAGING PLATES FOR USE WITH SYNCHROTRON-RADIATION [J].
AMEMIYA, Y .
JOURNAL OF SYNCHROTRON RADIATION, 1995, 2 :13-21
[4]  
AMEMIYA Y, 1994, P SYNCHR RAD BIOSC, P395
[5]   Fast compaction of α-lactalbumin during folding studied by stopped-flow X-ray scattering [J].
Arai, M ;
Ito, K ;
Inobe, T ;
Nakao, M ;
Maki, K ;
Kamagata, K ;
Kihara, H ;
Amemiya, Y ;
Kuwajima, K .
JOURNAL OF MOLECULAR BIOLOGY, 2002, 321 (01) :121-132
[6]   Calibration procedures for charge-coupled device x-ray detectors [J].
Barna, SL ;
Tate, MW ;
Gruner, SM ;
Eikenberry, EF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (07) :2927-2934
[7]   PILATUS:: a two-dimensional X-ray detector for macromolecular crystallography [J].
Eikenberry, EF ;
Brönnimann, C ;
Hülsen, G ;
Toyokawa, H ;
Horisberger, R ;
Schmitt, B ;
Schulze-Briese, C ;
Tomizaki, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 501 (01) :260-266
[8]  
ENGELNMULLGES G, 1996, NUMER ALGORITHMS, P309
[9]   The use of a Hamamatsu X-ray image intensifier with a cooled CCD as a solution X-ray scattering detector [J].
Fujisawa, T ;
Inoko, Y ;
Yagi, N .
JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 :1106-1114
[10]   Charge-coupled device area x-ray detectors [J].
Gruner, SM ;
Tate, MW ;
Eikenberry, EF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08) :2815-2842