Posterior pole retinal thickness measurements by the retinal thickness analyzer in healthy Chinese subjects

被引:19
作者
Chan, Chi-Ming
Yu, Jy-Haw
Chen, Li-Ju
Huang, Che-Hung
Lee, Chen-Tung
Lin, Tai-Chih
Liu, Der-Zen
机构
[1] Taipei Med Univ, Grad Inst Biomed Mat, Taipei, Taiwan
[2] Taipei Municipal Hosp, Dept Ophthalmol, Taipei, Taiwan
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2006年 / 26卷 / 02期
关键词
age; axial length; fovea; posterior pole; retinal thickness analyzer; spherical equivalent; sex;
D O I
10.1097/00006982-200602000-00009
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess retinal thickness at the posterior pole in healthy Chinese subjects with the retinal thickness analyzer (RTA). Methods: Retinal thicknesses at the posterior pole and fovea were measured by the RTA in 331 eyes of 178 healthy Chinese subjects. Retinal thicknesses as a function of sex, age, refractive errors, and axial length were also evaluated. Results: The average thickness of the foveal area +/- SD was 158.6 +/- 24.8 mu m, the average thickness of the perifoveal region (600-2,500 mu m from fovea) +/- SD was 174 +/- 25.2 mu m, and the average thickness of the posterior pole region (600-6,000 Am from fovea) +/- SD was 171.9 +/- 25.3 mu m. There was no significant difference in retinal thicknesses of the foveal, perifoveal, and posterior pole regions in either right or left eyes or as a function of different spherical equivalents. Moreover, there was no significant difference of foveal thickness between males and females. Greater retinal thicknesses of the foveal, perifoveal, and posterior pole regions were associated with age of older than 40 years and axial length of < 24 mm, and greater perifoveal and posterior pole thicknesses were found for females. Furthermore, there were no significant correlations between age, refractive errors, and axial lengths with retinal thicknesses. Conclusion: Retinal thicknesses of the posterior pole region differed by age, axial length, and sex, but there was no effect of laterality or different spherical equivalents. The RTA is a fast and noninvasive technology to assess retinal conditions with thickening or thinning in the fovea and posterior pole.
引用
收藏
页码:176 / 181
页数:6
相关论文
共 27 条
[21]   Quantitative analysis of diabetic macular edema after scatter laser photocoagulation with the scanning retinal thickness analyzer [J].
Tsujikawa, A ;
Kiryu, J ;
Dong, J ;
Yasukawa, T ;
Suzuma, I ;
Takagi, H ;
Ogura, Y .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1999, 19 (01) :59-64
[22]  
VANBUREN JM, 1963, PHYSL ANAT CORRELATI, P36
[23]   Macular thickness measurements in healthy subjects with different axial lengths using optical coherence tomography [J].
Wakitani, Y ;
Sasoh, M ;
Sugimoto, M ;
Ito, Y ;
Ido, M ;
Uji, Y .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2003, 23 (02) :177-182
[24]   Retinal thickness variation in the diabetic patient measured by the retinal thickness analyser [J].
Weinberger, D ;
Axer-Siegel, R ;
Landau, D ;
Yassur, Y .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (09) :1003-1006
[25]   Quantitative analysis of foveal retinal thickness in diabetic retinopathy with the scanning retinal thickness analyzer [J].
Yasukawa, T ;
Kiryu, J ;
Tsujikawa, A ;
Dong, J ;
Suzuma, I ;
Takagi, H ;
Ogura, Y .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1998, 18 (02) :150-155
[26]  
Zeimer R, 1996, INVEST OPHTH VIS SCI, V37, P1994
[27]   Quantitative detection of glaucomatous damage at the posterior pole by retinal thickness mapping -: A pilot study [J].
Zeimer, R ;
Asrani, S ;
Zou, SZ ;
Quigley, H ;
Jampel, H .
OPHTHALMOLOGY, 1998, 105 (02) :224-231