Randomized Controlled Trial of Osteoconductive Fixation Screws for Anterior Cruciate Ligament Reconstruction: A Comparison of the Calaxo and Milagro Screws

被引:41
作者
Bourke, Henry E. [1 ]
Salmon, Lucy J. [1 ]
Waller, Alison [1 ]
Winalski, Carl S. [3 ,4 ]
Williams, Heidi A. [1 ]
Linklater, James M. [2 ]
Vasanji, Amit [5 ]
Roe, Justin P. [1 ]
Pinczewski, Leo A. [1 ]
机构
[1] N Sydney Orthopaed & Sports Med Ctr, Mater Clin, Wollstonecraft, Australia
[2] Castlereagh Imaging, St Leonards, NSW, Australia
[3] Cleveland Clin, Imaging Inst, Cleveland, OH 44106 USA
[4] Cleveland Clin, Dept Biomed Engn, Lerner Res Inst, Cleveland, OH 44106 USA
[5] ImageIQ, Cleveland, OH USA
关键词
BIOABSORBABLE INTERFERENCE SCREWS; TITANIUM; LACTIDE; BONE;
D O I
10.1016/j.arthro.2012.10.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Purpose: To compare the outcome of 2 bioabsorbable screws for tibial interference fixation in anterior cruciate ligament reconstruction with reference to rate of absorption, osteoconductive properties, and clinical outcome. Methods: Patients undergoing primary anterior cruciate ligament reconstruction with hamstring autograft in a single unit were invited to participate in this study. Patients were randomized to receive either the Calaxo screw (Smith & Nephew, Andover, MA) or Milagro screw (DePuy Mitek, Raynham, MA) for tibial fixation. Patients were reviewed with subjective and objective evaluation by use of the International Knee Documentation Committee form, Lysholm score, KT-1000 arthrometry (MEDmetric, San Diego, CA), and clinical examination. Magnetic resonance imaging was performed at 1 year and computed tomography scanning at 1 week and at 6, 12, and 24 months. Results: Sixty patients agreed to participate in the study, with 32 patients randomized to the Calaxo screw and 28 to the Milagro screw for tibial fixation. There was no significant difference in subjective or objective clinical outcome between the 2 groups. At 24 months, 88% of Calaxo screws showed complete screw resorption compared with 0% of Milagro screws (P < .001). Tibial cysts were present in 88% of the Calaxo group and 7% of the Milagro group (P = .001). At 24 months, the mean volume of new bone formation for the Calaxo group was 21% of original screw volume. Ossification of the Milagro screw was unable to be accurately assessed as a result of incomplete screw resorption. Conclusions: Both screws showed similar favorable objective and subjective outcomes at 2 years. The Calaxo screw resorbed completely over a period of 6 months and was associated with a high incidence of intra-tunnel cyst formation. The Milagro screw increased in volume over a period of 6 months, followed by a gradual resorption, which was still ongoing at 2 years. Both screws were associated with tunnel widening, and neither showed evidence of significant tunnel ossification. We conclude that, despite satisfactory clinical outcomes, the addition of "osteoconductive" materials to bioabsorbable screws is not associated with bone formation at the screw site at 2 years. Level of Evidence: Level I, randomized controlled trial.
引用
收藏
页码:74 / 82
页数:9
相关论文
共 20 条
[1]
Long-Term Degradation of a Poly-Lactide Co-Glycolide/β-Tricalcium Phosphate Biocomposite Interference Screw [J].
Barber, F. Alan ;
Dockery, W. D. ;
Hrnack, Scott A. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (05) :637-643
[2]
The outcome at 15 years of endoscopic anterior cruciate ligament reconstruction using hamstring tendon autograft for 'isolated' anterior cruciate ligament rupture [J].
Bourke, H. E. ;
Gordon, D. J. ;
Salmon, L. J. ;
Waller, A. ;
Linklater, J. ;
Pinczewski, L. A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (05) :630-637
[3]
Effects of ACL interference screws on articular cartilage volume and thickness measurements with 1.5 T and 3 T MRI [J].
Bowers, M. E. ;
Tung, G. A. ;
Trinh, N. ;
Leventhal, E. ;
Crisco, J. J. ;
Kimia, B. ;
Fleming, B. C. .
OSTEOARTHRITIS AND CARTILAGE, 2008, 16 (05) :572-578
[4]
Cooper JJ, 2008, 54 ANN M ORTH RES SO
[5]
Cox Charles L, 2010, J Surg Orthop Adv, V19, P121
[6]
Tibial tunnel widening after bioresorbable poly-lactide calcium carbonate interference screw usage in ACL reconstruction [J].
Foldager, Casper ;
Jakobsen, Bent W. ;
Lund, Bent ;
Christiansen, Svend Erik ;
Kashi, Lotte ;
Mikkelsen, Lone R. ;
Lind, Martin .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (01) :79-84
[7]
Magnetic resonance imaging analysis of the bioabsorbable Milagro (TM) interference screw for graft fixation in anterior cruciate ligament reconstruction [J].
Frosch, K. -H. ;
Sawallich, T. ;
Schuetze, G. ;
Losch, A. ;
Walde, T. ;
Balcarek, P. ;
Konietschke, F. ;
Stuermer, K. M. .
STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2009, 4 (02) :73-79
[8]
A prospective randomized comparison of bioabsorbable and titanium anterior cruciate ligament interference screws [J].
Kaeding, C ;
Farr, J ;
Kavanaugh, T ;
Pedroza, A .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (02) :147-151
[9]
A clinical review of bioabsorbable interference screws and their adverse effects in anterior cruciate ligament reconstruction surgery [J].
Konan, S. ;
Haddad, F. S. .
KNEE, 2009, 16 (01) :6-13
[10]
Serial magnetic resonance imaging evaluation of a bioabsorbable interference screw and the adjacent bone [J].
Lajtai, G ;
Humer, K ;
Aitzetmüller, G ;
Unger, F ;
Noszian, I ;
Orthner, E .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (05) :481-488