European Resuscitation Council Guidelines for Resuscitation 2005 - Section 3. Electrical therapies: Automated external defibrillators, defibrillation., cardioversion and pacing

被引:90
作者
Deakin, CD
Nolan, JP
机构
关键词
D O I
10.1016/j.resuscitation.2005.10.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
引用
收藏
页码:S25 / S37
页数:13
相关论文
共 148 条
[61]   Initial energy for elective external cardioversion of persistent atrial fibrillation [J].
Joglar, JA ;
Hamdan, MH ;
Ramaswamy, K ;
Zagrodzky, JD ;
Sheehan, CJ ;
Nelson, LL ;
Andrews, TC ;
Page, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (03) :348-+
[62]   Effects of repeated electrical defibrillations on cardiac troponin I levels [J].
Joglar, JA ;
Kessler, DJ ;
Welch, PJ ;
Keffer, JH ;
Jessen, ME ;
Hamdan, MH ;
Page, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (02) :270-+
[63]   ORGANIZING AND IMPLEMENTING A HOSPITAL-WIDE FIRST-RESPONDER AUTOMATED EXTERNAL DEFIBRILLATION PROGRAM - STRENGTHENING THE IN-HOSPITAL CHAIN OF SURVIVAL [J].
KAYE, W ;
MANCINI, ME ;
RICHARDS, N .
RESUSCITATION, 1995, 30 (02) :151-156
[64]   TRANS-THORACIC RESISTANCE IN HUMAN DEFIBRILLATION - INFLUENCE OF BODY-WEIGHT, CHEST SIZE, SERIAL SHOCKS, PADDLE SIZE AND PADDLE CONTACT PRESSURE [J].
KERBER, RE ;
GRAYZEL, J ;
HOYT, R ;
MARCUS, M ;
KENNEDY, J .
CIRCULATION, 1981, 63 (03) :676-682
[65]  
Kerber RE, 1997, CIRCULATION, V95, P1677
[66]   SELF-ADHESIVE PREAPPLIED ELECTRODE PADS FOR DEFIBRILLATION AND CARDIOVERSION [J].
KERBER, RE ;
MARTINS, JB ;
KELLY, KJ ;
FERGUSON, DW ;
KOUBA, C ;
JENSEN, SR ;
NEWMAN, B ;
PARKE, JD ;
KIESO, R ;
MELTON, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (03) :815-820
[67]   ENERGY, CURRENT, AND SUCCESS IN DEFIBRILLATION AND CARDIOVERSION - CLINICAL-STUDIES USING AN AUTOMATED IMPEDANCE-BASED METHOD OF ENERGY ADJUSTMENT [J].
KERBER, RE ;
MARTINS, JB ;
KIENZLE, MG ;
CONSTANTIN, L ;
OLSHANSKY, B ;
HOPSON, R ;
CHARBONNIER, F .
CIRCULATION, 1988, 77 (05) :1038-1046
[68]   ADVANCE PREDICTION OF TRANS-THORACIC IMPEDANCE IN HUMAN DEFIBRILLATION AND CARDIOVERSION - IMPORTANCE OF IMPEDANCE IN DETERMINING THE SUCCESS OF LOW-ENERGY SHOCKS [J].
KERBER, RE ;
KOUBA, C ;
MARTINS, J ;
KELLY, K ;
LOW, R ;
HOYT, R ;
FERGUSON, D ;
BAILEY, L ;
BENNETT, P ;
CHARBONNIER, F .
CIRCULATION, 1984, 70 (02) :303-308
[69]   EXPERIMENTAL EVALUATION AND INITIAL CLINICAL-APPLICATION OF NEW SELF-ADHESIVE DEFIBRILLATION ELECTRODES [J].
KERBER, RE ;
MARTINS, JB ;
FERGUSON, DW ;
JENSEN, SR ;
PARKE, JD ;
KIESO, R ;
MELTON, J .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1985, 8 (01) :57-66
[70]   VENTRICULAR-TACHYCARDIA RATE AND MORPHOLOGY DETERMINE ENERGY AND CURRENT REQUIREMENTS FOR TRANSTHORACIC CARDIOVERSION [J].
KERBER, RE ;
KIENZLE, MG ;
OLSHANSKY, B ;
WALDO, AL ;
WILBER, D ;
CARLSON, MD ;
ASCHOFF, AM ;
BIRGER, S ;
FUGATT, L ;
WALSH, S ;
ROCKWELL, M ;
CHARBONNIER, F .
CIRCULATION, 1992, 85 (01) :158-163