Epinephrine quantification in pharmaceutical formulations utilizing plant tissue biosensors

被引:45
作者
Felix, Fabiana S. [1 ]
Yamashita, Miyuki [1 ]
Angnes, Lucio [1 ]
机构
[1] Univ Sao Paulo, Dept Quim Fundamental, Inst Quim, BR-05508900 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
epinephrine; biosensor; polyphenol oxidase; pharmaceutical products; amperometric detection; tissue biosensors;
D O I
10.1016/j.bios.2005.10.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A plant tissue biosensor associated with flow injection analysis is proposed to determine epinephrine in pharmaceutical samples. The polyphenol oxidase enzymes present in the fibers of a palm tree fruits (Livistona chinensis), catalyses the oxidation of epinephrine to epinephrinequinone as a primary product. This product is then electrochemically reduced (at -0.10 V versus Ag/AgClsat) on the biosensor surface and the resulting current is used for the quantification of epinephrine. The biosensor provides a linear response for epinephrine in the concentration range from 5.0 x 10(-5) to 3.5 x 10(-4) mol l(-1). The limit of detection estimated for this interval was 1.5 x 10(-5) mol l(-1) and the correlation coefficient of 0.998, working under a flow rate of 2.0 ml min(-1) and using a sample loop of 100 mu l. The repeatability (R.S.D. for 10 consecutive determinations of a 3.0 x 10(-4) mol l(-1) epinephrine solution) was 3.1%. The results obtained by the method here proposed were compared with the official UV spectrophotometric procedure and also using a plant tissue reactor. The responses obtained with the proposed strategies were in good agreement with both ways of analyses, whereas the values obtained by the official spectrophotometric method was strongly affected by benzoic acid, present in the formulation of pharmaceutical product utilized for inhalation. Such favorable results obtained with the carbon paste biosensor or utilizing the bioreactor, joined with the simplicity of its preparation turns these procedures very attractive for epinephrine quantification in pharmaceutical products. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2283 / 2289
页数:7
相关论文
共 38 条
  • [1] Flow-injection amperometric determination of dopamine in pharmaceuticals using a polyphenol oxidase biosensor obtained from soursop pulp
    Bezerra, VS
    De Lima, JL
    Montenegro, MCBSM
    Araújo, AN
    Da Silva, VL
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) : 1025 - 1031
  • [2] Analysis of epinephrine from fifteen different dental anesthetic formulations by capillary electrophoresis
    Britz-Mckibbin, P
    Wong, J
    Chen, DDY
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) : 535 - 540
  • [3] Quantitative assay fdr epinephrine in dental anesthetic solutions by capillary electrophoresis
    Britz-Mckibbin, P
    Kranack, AR
    Paprica, A
    Chen, DDY
    [J]. ANALYST, 1998, 123 (07) : 1461 - 1463
  • [4] On-line coupling of isolation in situ concentration integrated with derivative synchronous spectrofluorimetry for the simultaneous determination of epinephrine and norepinepluine in urine
    Canizares, P
    deCastro, MDL
    [J]. ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) : 335 - 341
  • [5] Determination of epinephrine and dopamine in pharmaceutical formulations using a biosensor based on carbon paste modified with crude extract of cara root (Dioscorea bulbifera)
    Caruso, CS
    Vieira, IC
    Fatibello-Filho, O
    [J]. ANALYTICAL LETTERS, 1999, 32 (01) : 39 - 50
  • [6] The electrochemical properties of dopamine, epinephrine, norepinephrine, and their electrocatalytic reactions on cobalt(II) hexacyanoferrate films
    Chen, SM
    Peng, KT
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 547 (02) : 179 - 189
  • [7] Multi-mode in situ spectroelectrochemical studies of redox pathways of adrenaline
    Cui, H
    Wu, LS
    Chen, J
    Lin, XQ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 504 (02): : 195 - 200
  • [8] FLOW-INJECTION CHEMILUMINOMETRIC DETERMINATION OF EPINEPHRINE, NOREPINEPHRINE, DOPAMINE AND L-DOPA
    DEFTEREOS, NT
    CALOKERINOS, AC
    EFSTATHIOU, CE
    [J]. ANALYST, 1993, 118 (06) : 627 - 632
  • [9] Garrido EM, 1997, J PHARMACEUT BIOMED, V15, P845
  • [10] Determination of catecholamines in sheep plasma by high-performance liquid chromatography with electrochemical detection: comparison of deoxyepinephrine and 3,4-dihydroxybenzylamine as internal standard
    He, HB
    Stein, CM
    Christman, B
    Wood, AJJ
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 701 (01): : 115 - 119