Determination of human serum albumin using aurothiomalate as electroactive label

被引:4
作者
de la Escosura-Muñiz, A [1 ]
González-García, MB [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Asturias, Spain
关键词
electroactive label; aurothiomalate; immunosensor; rabbit IgG; human serum albumin; glassy-carbon electrode;
D O I
10.1007/s00216-005-0213-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new electroactive label has been used to monitor immunoassays in the determination of human serum albumin (HSA) using glassy-carbon electrodes as supports for the immunological reactions. The label was a gold(I) complex, sodium aurothiomalate, which was bound to rabbit IgG anti-human serum albumin (anti-HSA-Au). The HSA was adsorbed on the electrode surface and the immunological reaction with gold-labelled anti-HSA was then performed for one hour by non-competitive or competitive procedures. The gold(I) bound to the anti-HSA was electrodeposited in 0.1 mol L-1 HCl at -1.00 V for 5 min then oxidised in 0.1 mol L-1 H2SO4 solution at +1.40 V for 1 min. Silver electrodeposition at -0.14 V for 1 min followed by anodic stripping voltammetry were then performed in aqueous 1.0 mol L-1 NH3-2.0x10(-4) mol L-1 AgNO3. For both non-competitive and competitive formats, calibration plots in the ranges 5.0x10(-10) to 1.0x10(-8) mol L-1 and 1.0x10(-10) to 1.0x10(-9) mol L-1 HSA, respectively, with estimated detection limits of 1.5x10(-10) mol L-1 (10 ng mL(-1)) and 1.0x10(-10) mol L-1 (7 ng mL(-1)), respectively, were obtained. Levels of HSA in two healthy volunteer urine samples were also evaluated, using both immunoassay formats.
引用
收藏
页码:742 / 750
页数:9
相关论文
共 29 条
[1]  
ANVARHUSEIN A, 1981, J CHEM SOC DALTON, P1657
[2]  
COFFER MT, 1986, INORG CHEM, V25, P333
[3]   Electrocatalytic detection of aurothiomalate on carbon electrodes -: Application as a non-enzymatic label to the quantification of proteins [J].
de la Escosura-Muñiz, A ;
González-García, MB ;
Costa-García, A .
ANALYTICA CHIMICA ACTA, 2004, 524 (1-2) :355-363
[4]   Catalytic effect on silver electrodeposition of gold deposited on carbon electrodes [J].
de la Escosura-Muñiz, A ;
González-García, MB ;
Costa-García, A .
ELECTROANALYSIS, 2004, 16 (19) :1561-1568
[5]   An electrochemical metalloimmunoassay based on a colloidal gold label [J].
Dequaire, M ;
Degrand, C ;
Limoges, B .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5521-5528
[6]   HETEROGENEOUS IMMUNOASSAY FOR SERUM-PROTEINS BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
DOYLE, MJ ;
HALSALL, HB ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2318-2322
[7]   REACTIONS OF THE METALLODRUG AURANOFIN [(1-THIO-BETA-D-GLUCOPYRANOSE-2,3,4,6-TETRAACETATO-S)(TRIETHYLPHOSPHINE)GOLD] WITH BIOLOGICAL LIGANDS STUDIED BY RADIOISOTOPE METHODOLOGY [J].
ECKER, DJ ;
HEMPEL, JC ;
SUTTON, BM ;
KIRSCH, R ;
CROOKE, ST .
INORGANIC CHEMISTRY, 1986, 25 (18) :3139-3143
[8]   Colloidal gold as an electrochemical label of streptavidin-biotin interaction [J].
González-García, MB ;
Fernández-Sánchez, C ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (5-6) :315-321
[9]   Silver electrodeposition catalyzed by colloidal gold on carbon paste electrode:: application to biotin-streptavidin interaction monitoring [J].
González-García, MB ;
Costa-García, A .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :663-670
[10]   Electrochemical immunoassay based on catalytic conversion of substrate by labeled metal ion and polarographic detection of the product generated [J].
Guo, W ;
Song, JF ;
Zhao, MR ;
Wang, JX .