Determination of human serum albumin using aurothiomalate as electroactive label

被引:4
作者
de la Escosura-Muñiz, A [1 ]
González-García, MB [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, E-33006 Oviedo, Asturias, Spain
关键词
electroactive label; aurothiomalate; immunosensor; rabbit IgG; human serum albumin; glassy-carbon electrode;
D O I
10.1007/s00216-005-0213-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new electroactive label has been used to monitor immunoassays in the determination of human serum albumin (HSA) using glassy-carbon electrodes as supports for the immunological reactions. The label was a gold(I) complex, sodium aurothiomalate, which was bound to rabbit IgG anti-human serum albumin (anti-HSA-Au). The HSA was adsorbed on the electrode surface and the immunological reaction with gold-labelled anti-HSA was then performed for one hour by non-competitive or competitive procedures. The gold(I) bound to the anti-HSA was electrodeposited in 0.1 mol L-1 HCl at -1.00 V for 5 min then oxidised in 0.1 mol L-1 H2SO4 solution at +1.40 V for 1 min. Silver electrodeposition at -0.14 V for 1 min followed by anodic stripping voltammetry were then performed in aqueous 1.0 mol L-1 NH3-2.0x10(-4) mol L-1 AgNO3. For both non-competitive and competitive formats, calibration plots in the ranges 5.0x10(-10) to 1.0x10(-8) mol L-1 and 1.0x10(-10) to 1.0x10(-9) mol L-1 HSA, respectively, with estimated detection limits of 1.5x10(-10) mol L-1 (10 ng mL(-1)) and 1.0x10(-10) mol L-1 (7 ng mL(-1)), respectively, were obtained. Levels of HSA in two healthy volunteer urine samples were also evaluated, using both immunoassay formats.
引用
收藏
页码:742 / 750
页数:9
相关论文
共 29 条
[21]  
MOLLERPEDERSEN S, 1986, ANN RHEUM DIS, V45, P712
[22]   Development of piezoelectric immunosensors for measurement of albuminuria [J].
Navrátilová, I ;
Skládal, P ;
Viklicky, V .
TALANTA, 2001, 55 (04) :831-839
[23]  
PURI A, 1985, CLIN CHEM, V31, P1241
[24]   High-resolution and high-throughput protocols for measuring drug/human serum albumin interactions using BIACORE [J].
Rich, RL ;
Day, YSN ;
Morton, TA ;
Myszka, DG .
ANALYTICAL BIOCHEMISTRY, 2001, 296 (02) :197-207
[25]   Glow-discharge treated piezoelectric quartz crystals as immunosensors for HSA detection [J].
Saber, R ;
Mutlu, S ;
Piskin, E .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (09) :727-734
[26]   Disposable HSA QCM-immunosensor for practical measurement in liquid [J].
Sakti, SP ;
Hauptmann, P ;
Zimmermann, B ;
Bühling, F ;
Ansorge, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :257-262
[27]   Metal-protein complex-mediated transport and delivery of Ni2+ to TCR/MHC contact sites in nickel-specific human T cell activation [J].
Thierse, HJ ;
Moulon, C ;
Allespach, Y ;
Zimmermann, B ;
Doetze, A ;
Kuppig, S ;
Wild, D ;
Herberg, F ;
Weltzien, HU .
JOURNAL OF IMMUNOLOGY, 2004, 172 (03) :1926-1934
[28]   Thick film electrochemical immunosensor based on stripping potentiometric detection of a metal ion label [J].
Wang, J ;
Tian, BM ;
Rogers, KR .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1682-1685
[29]   Flow injection renewable surface immunoassay for real time monitoring of biospecific interactions [J].
Willumsen, B ;
Christian, GD ;
Ruzicka, J .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3482-3489