Aurothiomalate as an electroactive label for the determination of immunoglobulin M using glassy carbon electrodes as immunoassay transducers

被引:8
作者
de la Escosura-Muñiz, A [1 ]
González-García, MBE [1 ]
Costa-García, A [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Asturias, Spain
关键词
electroactive label; aurothiomalate; immunosensor; rabbit IgG; immunoglobulin M; glassy carbon electrode;
D O I
10.1016/j.snb.2005.05.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new electroactive label was used for monitoring immunoassays for the determination of human immunoglobulin M (IgM) using glassy carbon electrodes as supports of the immunological reactions. Aurothiomalate, a gold (1) complex, was bound to rabbit IgG anti-human IgM (RIgG-Au). The IgM was adsorbed on the electrode surface and then the immunological reaction with gold-labelled RIgG was carried out for an hour following non-competitive and competitive procedures. The analytical signal was based on the catalytic effect of gold deposited on the electrode surface upon silver electrodeposition. The gold (1) bound to the RIgG was electrodeposited in a 0.1 M HCl at -1.00 V for 5 min, and then, oxidised in a 0.1 M H2SO4 Solution, at + 1.40 V for 1 min. Then, silver electrodeposition at -0.14 V for 1 min followed by an anodic stripping voltammetry were carried out in aqueous 1.0M NH3-2.0 x 10(-4) M AgNO3. For both immunoassay formats, calibration curves in the range of 7.5 x 10(-11) to 1.0 x 10(-1) m of IgM were obtained with an estimated detection limit of 2.8 x 10(-11) M (25 ng/ml). Moreover, the levels of IgM in synthetic serum were evaluated, applying the method of standard additions following both formats competitive and non-competitive. These samples were previously pretreated in order to remove most of the albumin and IgG, which interfered in the electrochemical detection. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:473 / 481
页数:9
相关论文
共 26 条
[21]   Amperometric immunosensors and enzyme electrodes for environmental applications [J].
Parellada, J ;
Narváez, A ;
López, MA ;
Domínguez, E ;
Fernández, JJ ;
Pavlov, V ;
Katakis, I .
ANALYTICA CHIMICA ACTA, 1998, 362 (01) :47-57
[22]   Pulsed electrochemical technique for monitoring antibody-antigen reactions at interfaces [J].
Sargent, A ;
Sadik, OA .
ANALYTICA CHIMICA ACTA, 1998, 376 (01) :125-131
[23]   An immunosensor based on disposable electrodes for rapid estimation of fatty acid-binding protein, an early marker of myocardial infarction [J].
Schreiber, A ;
Feldbrugge, R ;
Key, G ;
Glatz, JFC ;
Spener, F .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (11) :1131-1137
[24]  
Snejdárková M, 2000, ELECTROANAL, V12, P940, DOI 10.1002/1521-4109(200008)12:12<940::AID-ELAN940>3.0.CO
[25]  
2-V
[26]   Thick film electrochemical immunosensor based on stripping potentiometric detection of a metal ion label [J].
Wang, J ;
Tian, BM ;
Rogers, KR .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1682-1685