Accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling

被引:28
作者
Hedtjärn, H [1 ]
Carlsson, GA
Williamson, JF
机构
[1] Linkoping Univ, Dept Radiat Phys, S-58185 Linkoping, Sweden
[2] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, Radiat Oncol Ctr, St Louis, MO 63110 USA
关键词
D O I
10.1088/0031-9155/47/3/301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Current brachytherapy dose calculations ignore applicator attenuation and tissue heterogeneities, assuming isolated sources embedded in unbounded medium. Conventional Monte Carlo (MC) dose calculations, while accurate, are too slow for practical treatment planning. This study evaluates the efficacy of correlated sampling in reducing the variance of MC photon transport simulation in typical brachytherapy geometries. Photon histories were constructed in the homogeneous geometry and weight correction factors applied to account for the perturbing effect of heterogeneities. Two different estimators, expected value track-length (ETL) and analogue (ANL), were used. The method was tested for disc-shaped heterogeneities and point-isotropic sources as well as for a model 6702 I-125 seed. Uncorrelated ETL estimation was 10-100 times more efficient than its ANL counterpart. Correlated ETL estimation offered efficiency gains as large as 10(4) in regions where dose perturbations are small (<5%). For perturbations of 40-50%, efficiency gains were in some cases even less than unity. However, correlated ETL was capable of producing less than 2% (1 standard deviation) uncertainty in more than 90% of the voxels in 1 CPU hour. Correlated sampling significantly improves efficiency under selected circumstances and, in combination with other variance reduction strategies, may make MC-based treatment planning a reality for brachytherapy.
引用
收藏
页码:351 / 376
页数:26
相关论文
共 29 条
[1]   AN ANALYTIC THEORY OF THE POINT-SOURCE NONUNIFORMITY CORRECTION FACTOR FOR THICK-WALLED IONIZATION CHAMBERS IN PHOTON BEAMS [J].
BIELAJEW, AF .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (04) :517-538
[2]   Two-dimensional discrete ordinates photon transport calculations for brachytherapy dosimetry applications [J].
Daskalov, GM ;
Baker, RS ;
Little, RC ;
Rogers, DWO ;
Williamson, JF .
NUCLEAR SCIENCE AND ENGINEERING, 2000, 134 (02) :121-134
[3]   THE APPLICATION OF CORRELATED SAMPLING TO THE COMPUTATION OF ELECTRON-BEAM DOSE DISTRIBUTIONS IN HETEROGENEOUS PHANTOMS USING THE MONTE-CARLO METHOD [J].
HOLMES, MA ;
MACKIE, TR ;
SOHN, W ;
RECKWERDT, PJ ;
KINSELLA, TJ ;
BIELAJEW, AF ;
ROGERS, DWO .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (06) :675-688
[4]  
*ICRU, 1998, 60 ICRU INT COM RAD
[5]   Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields [J].
Kirov, AS ;
Williamson, JF ;
Meigooni, AS ;
Zhu, Y .
MEDICAL PHYSICS, 1996, 23 (06) :911-919
[6]   VOLUME-BASED GEOMETRIC MODELING FOR RADIATION TRANSPORT CALCULATIONS [J].
LI, ZF ;
WILLIAMSON, JF .
MEDICAL PHYSICS, 1992, 19 (03) :667-677
[8]   VARIANCE VERSUS EFFICIENCY IN TRANSPORT MONTE-CARLO [J].
LUX, I .
NUCLEAR SCIENCE AND ENGINEERING, 1980, 73 (01) :66-75
[9]  
Lux I., 1991, MONTE CARLO PARTICLE
[10]   Correction factors for water-proofing sleeves in kilovoltage x-ray beams [J].
Ma, CM ;
Seuntjens, JP .
MEDICAL PHYSICS, 1997, 24 (09) :1507-1513