Improved Opacification of a Suboptimally Enhanced Pulmonary Artery in Chest CT: Experience Using a Dual-Layer Detector Spectral CT

被引:68
作者
Bae, Kyungsoo [1 ,2 ]
Jeon, Kyung Nyeo [1 ,2 ]
Cho, Soo Buem [2 ]
Park, Sung Eun [2 ]
Moon, Jin Il [2 ]
Baek, Hye Jin [1 ,2 ]
Choi, Bo Hwa [2 ]
机构
[1] Gyeongsang Natl Univ, Sch Med, Inst Hlth Sci, Dept Radiol, 90 Chilam Dong, Jinju 660702, Gyeongsang Nam, South Korea
[2] Gyeongsang Natl Univ, Changwon Hosp, Dept Radiol, Chang Won, South Korea
关键词
chest CT; pulmonary artery; spectral CT; suboptimal contrast enhancement; virtual monoenergetic image; virtual monoenergetic imaging (VMI); COMPUTED-TOMOGRAPHY ANGIOGRAPHY; REDUCED IODINE LOAD; IMAGE-QUALITY; CONTRAST ENHANCEMENT; DIAGNOSTIC-ACCURACY; ENERGY; RECONSTRUCTION; OPTIMIZATION; REDUCTION; EMBOLISM;
D O I
10.2214/AJR.17.18537
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The objective of our study was to evaluate the quality of virtual monoenergetic imaging (VMI) from dual-layer detector spectral CT and the effect of virtual monoenergetic images obtained at low energies on the detection of pulmonary embolism (PE) in patients with a suboptimally enhanced pulmonary artery on chest CT. MATERIALS AND METHODS. Of 1552 consecutive chest CT examinations performed with dual-layer detector spectral CT using a routine protocol with a tube voltage of 120 kVp, 79 examinations with suboptimal enhancement of the pulmonary artery (i.e., mean attenuation of pulmonary artery <= 180 HU) were included. The mean attenuation of the pulmonary artery, noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) of virtual monoenergetic images obtained at 40-200 keV were compared with those of the conventional 120-kVp images. The virtual monoenergetic images with the best CNR were compared with the 120-kVp images with regard to subjective image quality and diagnostic accuracy for detecting PE. RESULTS. Sufficient attenuation of the pulmonary artery (> 180 HU) was obtained using VMI for 78 of the 79 examinations. The noise levels of the virtual monoenergetic images were gradually increased with decreasing energy level (i.e., kiloelectron volt setting). The CNR and SNR of virtual monoenergetic images at 40-65 keV were significantly higher (both, p < 0.001) than the CNR and SNR of the 120-kVp images. The CNR was the highest at 40 keV for all cases. Diagnostic accuracy for detecting PE was significantly higher for 40-keV images (reader 1: AUC = 0.992, p = 0.033; reader 2: AUC = 0.986, p = 0.043) than for 120-kVp images (reader 1, AUC = 0.911; reader 2, AUC = 0.933). The subjective quality was not different between these two images. CONCLUSION. In chest CT examinations in which the pulmonary artery is suboptimally enhanced, obtaining virtual monoenergetic images at a low energy setting using dual-layer detector spectral CT allows sufficient attenuation of the pulmonary artery to be achieved while preserving image quality and increasing diagnostic performance for detecting PE.
引用
收藏
页码:734 / 741
页数:8
相关论文
共 33 条
[1]
State-of-the-Art Pulmonary CT Angiography for Acute Pulmonary Embolism [J].
Albrecht, Moritz H. ;
Bickford, Matthew W. ;
Nance, John W., Jr. ;
Zhang, Longjiang ;
De Cecco, Carlo N. ;
Wichmann, Julian L. ;
Vogl, Thomas J. ;
Schoepf, U. Joseph .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (03) :495-504
[2]
Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen [J].
Albrecht, Moritz H. ;
Trommer, Jesko ;
Wichmann, Julian L. ;
Scholtz, Jan-Erik ;
Martin, Simon S. ;
Lehnert, Thomas ;
Vogl, Thomas J. ;
Bodelle, Boris .
INVESTIGATIVE RADIOLOGY, 2016, 51 (09) :582-590
[3]
ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[4]
Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography [J].
Apfaltrer, Paul ;
Sudarski, Sonja ;
Schneider, David ;
Nance, John W., Jr. ;
Haubenreisser, Holger ;
Fink, Christian ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :322-328
[5]
The frequency of incidental pulmonary embolism in different CT examinations [J].
Bach, Andreas G. ;
Meyer, Hans J. ;
Taute, Bettina-Maria ;
Surov, Alexey .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058)
[6]
Optimization of Contrast Enhancement in Thoracic MDCT [J].
Bae, Kyongtae T. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2010, 48 (01) :9-+
[7]
Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging [J].
Beeres, Martin ;
Trommer, Jesko ;
Frellesen, Claudia ;
Nour-Eldin, Nour-Eldin A. ;
Scholtz, Jan E. ;
Herrmann, Eva ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (01) :137-144
[8]
Has respiratory coaching" before deep inspiration an impact on the incidence of transient contrast interruption during pulmonary CT angiography?" [J].
Juan M. Bernabé-García ;
Cristina García-Espasa ;
Juan Arenas-Jiménez ;
José Sánchez-Payá ;
Javier de la Hoz-Rosa ;
Joan O. Carreres-Polo .
Insights into Imaging, 2012, 3 (5) :505-511
[9]
Management of the Incidental Pulmonary Embolism [J].
Chiu, Victor ;
O'Connell, Casey .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (03) :485-488
[10]
Spectral Optimization of Chest CT Angiography with Reduced Iodine Load: Experience in 80 Patients Evaluated with Dual-Source, Dual-Energy CT [J].
Delesalle, Marie-Aurelie ;
Pontana, Francois ;
Duhamel, Alain ;
Faivre, Jean-Baptiste ;
Flohr, Thomas ;
Tacelli, Nunzia ;
Remy, Jacques ;
Remy-Jardin, Martine .
RADIOLOGY, 2013, 267 (01) :256-266