Optimization of Contrast Enhancement in Thoracic MDCT

被引:80
作者
Bae, Kyongtae T. [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
关键词
Contrast agents; Intravenous; CT technology; Optimization; MDCT; Thorax; MULTIDETECTOR ROW CT; NONINVASIVE CORONARY-ANGIOGRAPHY; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; ABDOMINAL AORTIC-ANEURYSMS; BIPHASIC SPIRAL CT; HEPATIC HELICAL CT; TO-LIVER CONTRAST; BODY-MASS INDEX; PULMONARY ANGIOGRAPHY; IODINE CONCENTRATION;
D O I
10.1016/j.rcl.2009.08.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Many clinical applications of thoracic computed tomography (CT) require contrast medium to enhance and delineate vascular, mediastinal, hilar, and cardiac structures, and differentiate normal and pathologic vascular or tumoral conditions. Multi-detector row computed tomography (MDCT) is superior to single-detector row CT (SDCT) because MDCT permits more efficient and flexible use of intravenous contrast medium to achieve enhancement. However, to fully reap the benefits of MDCT contrast enhancement, the technical challenges associated with optimizing enhancement and scan timing in MDCT need to be solved. This article reviews the basic principles of CT contrast enhancement and discusses common clinical considerations and the protocol design modifications that are necessary to achieve optimal contrast enhancement in thoracic MDCT.
引用
收藏
页码:9 / +
页数:22
相关论文
共 167 条
[1]
Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation [J].
Achenbach, S ;
Ropers, D ;
Pohle, FK ;
Raaz, D ;
von Erffa, J ;
Yilmaz, A ;
Muschiol, G ;
Daniel, WG .
EUROPEAN HEART JOURNAL, 2005, 26 (19) :1978-1986
[2]
Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT [J].
Awai, K ;
Inoue, M ;
Yagyu, Y ;
Watanabe, M ;
Sano, T ;
Nin, S ;
Koike, R ;
Nishimura, Y ;
Yamashita, Y .
RADIOLOGY, 2004, 233 (03) :682-688
[3]
Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[4]
Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT [J].
Awai, K ;
Hori, S .
EUROPEAN RADIOLOGY, 2003, 13 (09) :2155-2160
[5]
Aortic and hepatic enhancement and tumor-to-liver contrast: Analysis of the effect of different concentrations of contrast material at multi-detector row helical CV [J].
Awai, K ;
Takada, K ;
Onishi, H ;
Hori, S .
RADIOLOGY, 2002, 224 (03) :757-763
[6]
Awai Kazuo, 2004, Radiat Med, V22, P303
[7]
Timing of the hepatic arterial phase during contrast-enhanced computed tomography of the liver -: Assessment of normal values in 25 volunteers [J].
Bader, TR ;
Prokesch, RW ;
Grabenwöger, F .
INVESTIGATIVE RADIOLOGY, 2000, 35 (08) :486-492
[8]
Multiphasic injection method for uniform prolonged vascular enhancement at CT angiography: Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Tran, HQ ;
Heiken, JP .
RADIOLOGY, 2000, 216 (03) :872-880
[9]
Scan and contrast administration principles of MDCT [J].
Bae, KT ;
Heiken, JP .
EUROPEAN RADIOLOGY, 2005, 15 :E46-E59
[10]
CT depiction of pulmonary emboli: Display window settings [J].
Bae, KT ;
Mody, GN ;
Balfe, DM ;
Bhalla, S ;
Gierada, DS ;
Gutierrez, FR ;
Menias, CO ;
Woodard, PK ;
Goo, IM ;
Hildebolt, CF .
RADIOLOGY, 2005, 236 (02) :677-684