Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT

被引:82
作者
Awai, K
Inoue, M
Yagyu, Y
Watanabe, M
Sano, T
Nin, S
Koike, R
Nishimura, Y
Yamashita, Y
机构
[1] Kinki Univ, Sch Med, Dept Radiol, Osaka 5898511, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Radiol, Kumamoto, Japan
关键词
aorta; CT; computed tomography (CT); contrast media; liver; diseases; liver neoplasms;
D O I
10.1148/radiol.2333031617
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively evaluate aortic and hepatic enhancement and depiction of hypervascular hepatocellular carcinoma (HCC) between two contrast materials with moderate and high iodine concentrations when administered at same iodine dose and injection duration at multi - detector row helical computed tomography (CT). MATERIALS AND METHODS: Institutional review board approval and informed patient consent were obtained. One hundred eighty-six patients were studied, and 67 patients with hypervascular HCC were identified. Ninety-four patients were assigned to receive iohexol 350 (mg iodine per milliliter) with protocol A; 92, iohexol 300 with protocol B. In both protocols, iohexol with same iodine load per weight ( 518 mg/kg) was administered with same injection duration ( 25 seconds). Multiphase CT scanning was started 10, 20, 50, and 180 seconds after the trigger ( threshold level set at increase of 100 HU over baseline CT number of aorta). Enhancement of aorta and liver was measured in 186 patients. Tumor-to-liver contrast was measured in 67 patients with hypervascular HCC. Statistical analysis was performed with Mann-Whitney U test. RESULTS: Medians of aortic enhancement during four phases were 325, 185, 112, and 69 HU with protocol A. Corresponding values were 344, 266, 121, and 73 HU with protocol B. During all phases, aortic enhancement was significantly higher with protocol B ( P =.046, P <.001, P <.001, and P =.002). Hepatic enhancement during four phases was 6, 21, 48, and 34 HU with protocol A. Corresponding values were 3, 17, 47, and 35 HU with protocol B. Hepatic enhancement was significantly higher with protocol A during first and second phases ( P <.001 for both), although there was no significant difference between protocols during third and fourth phases ( P =.778 and P =.178, respectively). Medians of tumor-to-liver contrast during four phases were 22, 34, 0.5, and - 1.1 HU with protocol A. Corresponding values were 23, 45, 0, and - 8.6 HU with protocol B. Tumor-to-liver contrast was significantly higher with protocol B during second phase ( P =.049), although there was no difference between protocols during other phases. CONCLUSION: When total iodine dose was adjusted to body weight and injection duration was fixed, rapid administration of moderate concentration of contrast material was more effective for depiction of hypervascular HCC than was high concentration of contrast material.
引用
收藏
页码:682 / 688
页数:7
相关论文
共 34 条
[1]   Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[2]   Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT [J].
Awai, K ;
Hori, S .
EUROPEAN RADIOLOGY, 2003, 13 (09) :2155-2160
[3]   Aortic and hepatic enhancement and tumor-to-liver contrast: Analysis of the effect of different concentrations of contrast material at multi-detector row helical CV [J].
Awai, K ;
Takada, K ;
Onishi, H ;
Hori, S .
RADIOLOGY, 2002, 224 (03) :757-763
[4]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[5]   Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[6]   UNDERSTANDING AND OPTIMIZING USE OF CONTRAST MATERIAL FOR CT OF THE LIVER [J].
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :323-331
[7]   DOSE REQUIREMENTS FOR A NONIONIC CONTRAST AGENT FOR SPIRAL COMPUTED-TOMOGRAPHY OF THE LIVER IN RABBITS [J].
BLUEMKE, DA ;
FISHMAN, EK ;
ANDERSON, JH .
INVESTIGATIVE RADIOLOGY, 1994, 29 (02) :195-200
[8]   EFFECT OF CONTRAST CONCENTRATION ON ABDOMINAL ENHANCEMENT IN THE RABBIT - SPIRAL COMPUTED-TOMOGRAPHY EVALUATION [J].
BLUEMKE, DA ;
FISHMAN, EK ;
ANDERSON, JH .
ACADEMIC RADIOLOGY, 1995, 2 (03) :226-231
[9]   Use of high concentration contrast media (HCCM): principles and rationale - body CT [J].
Brink, JA .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 :S53-S58
[10]   HEPATIC SPIRAL CT - REDUCTION OF DOSE OF INTRAVENOUS CONTRAST MATERIAL [J].
BRINK, JA ;
HEIKEN, JP ;
FORMAN, HP ;
SAGEL, SS ;
MOLINA, PL ;
BROWN, PC .
RADIOLOGY, 1995, 197 (01) :83-88