Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight

被引:201
作者
Awai, K
Hiraishi, K
Hori, S
机构
[1] Kumamoto Univ, Grad Sch Med Sci, Dept Radiol, Kumamoto 8608556, Japan
[2] Kinki Univ, Sch Med, Dept Radiol, Osaka 589, Japan
[3] Rinku Gen Med Ctr, Dept Radiol, Osaka, Japan
关键词
aorta; CT; computed tomography (CT) contrast enhancement;
D O I
10.1148/radiol.2301021008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the effect of duration and rate of contrast material injection on aortic peak time and peak enhancement in an injection protocol in which the contrast material dose is adjusted according to patient weight. MATERIALS AND METHODS: One hundred ninety-nine patients were randomly divided into three groups in which the fixed duration of contrast material injection was 5 seconds (group A) or 35 seconds (group B) or the fixed injection rate wads 4.0 mL/sec (group C). Computed tomography (CT) at the L3 vertebral level was performed before and after contrast material injection. Aortic peak time, aortic peak enhancement, and period when aortic enhancement is 200 HU or greater (T200) were calculated. The Pearson product-moment correlation coefficient (r) was used to investigate relationships between patient weight and aortic peak time, aortic peak enhancement, and T200 in each group. RESULTS: A significant correlation between aortic peak time and patient weight (r = 0.91, P < .001) was observed in group C. No significant correlations between patient weight and aortic peak time were observed in group A (r =, 0.16, P = .21) or B (r = -0.05, P = .69). A significant inverse correlation between aortic peak enhancement and patient weight (r = -0.70, P < .001) was observed in group C. No significant correlations between patient weight and aortic peak enhancement were observed in group A (r = 0.09, P = .48) or B (r = 0.10, P = .41). A significant correlation between T200 and patient weight (r = 0.72, P < .001) was observed in group C. No significant correlations between patient weight and T200 were observed in group A (r = 0.12, P = .34) or B (r = 0.001, P = .99). CONCLUSION: Aortic peak time, aortic peak enhancement, and T200 were closely related to injection duration in the protocol with contrast material dose determined according to patient weight. (C) RSNA, 2004.
引用
收藏
页码:142 / 150
页数:9
相关论文
共 35 条
[1]   Aortic and hepatic contrast medium enhancement at CT part I. Prediction with a computer model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :647-655
[2]   Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[3]   Hepatocellular carcinoma: Evaluation with biphasic, contrast-enhanced, helical CT [J].
Baron, RL ;
Oliver, JH ;
Dodd, GD ;
Nalesnik, M ;
Holbert, BL ;
Carr, B .
RADIOLOGY, 1996, 199 (02) :505-511
[4]   HELICAL CT OF THE LIVER - VALUE OF AN EARLY HEPATIC ARTERIAL PHASE [J].
BONALDI, VM ;
BRET, PM ;
REINHOLD, C ;
ATRI, M .
RADIOLOGY, 1995, 197 (02) :357-363
[5]   HEPATIC SPIRAL CT - REDUCTION OF DOSE OF INTRAVENOUS CONTRAST MATERIAL [J].
BRINK, JA ;
HEIKEN, JP ;
FORMAN, HP ;
SAGEL, SS ;
MOLINA, PL ;
BROWN, PC .
RADIOLOGY, 1995, 197 (01) :83-88
[6]   Multiphase hepatic CT with a multirow detector CT scanner [J].
Foley, WD ;
Mallisee, TA ;
Hohenwalter, MD ;
Wilson, CR ;
Quiroz, FA ;
Taylor, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (03) :679-685
[7]   HEPATIC HELICAL CT - CONTRAST MATERIAL INJECTION PROTOCOL [J].
FOLEY, WD ;
HOFFMANN, RG ;
QUIROZ, FA ;
KAHN, CE ;
PERRET, RS .
RADIOLOGY, 1994, 192 (02) :367-371
[8]   Timing of parenchymal enhancement on dual-phase dynamic helical CT of the liver: How long does the hepatic arterial phase predominate? [J].
Frederick, MG ;
McElaney, BL ;
Singer, A ;
Park, KS ;
Paulson, EK ;
McGee, SG ;
Nelson, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1305-1310
[9]   Hepatic CT enhancement: effect of the rate and volume of contrast medium injection in an animal model [J].
Garcia, P ;
Genin, G ;
Bret, PM ;
Bonaldi, VM ;
Reinhold, C ;
Atri, M .
ABDOMINAL IMAGING, 1999, 24 (06) :597-603
[10]   Effect of rate of contrast medium injection on hepatic enhancement at CT [J].
Garcia, PA ;
Bonaldi, VM ;
Bret, PM ;
Liang, LJ ;
Reinhold, C ;
Atri, M .
RADIOLOGY, 1996, 199 (01) :185-189