Validation of CT dose-reduction simulation

被引:82
作者
Massoumzadeh, Parinaz [1 ]
Don, Steven [1 ]
Hildebolt, Charles F. [1 ]
Bae, Kyongtae T. [1 ]
Whiting, Bruce R. [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
computed tomography; CT; noise modeling; dose reduction; bowtie filter; tube current modulation; observer study; four-alternative forced-choice (4AFC); just noticeable difference (JND); X-RAY CT; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; SINOGRAM DATA; NOISE; RECONSTRUCTION; VARIANCE;
D O I
10.1118/1.3031114
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this research was to develop and validate a custom computed tomography dose-reduction simulation technique for producing images that have an appearance consistent with the same scan performed at a lower mAs (with fixed kVp, rotation time, and collimation). Synthetic noise is added to projection (sinogram) data, incorporating a stochastic noise model that includes energy-integrating detectors, tube-current modulation, bowtie beam filtering, and electronic system noise. Experimental methods were developed to determine the parameters required for each component of the noise model. As a validation, the outputs of the simulations were compared to measurements with cadavers in the image domain and with phantoms in both the sinogram and image domain, using an unbiased root-mean-square relative error metric to quantify agreement in noise processes. Four-alternative forced-choice (4AFC) observer studies were conducted to confirm the realistic appearance of simulated noise, and the effects of various system model components on visual noise were studied. The "just noticeable difference (JND)" in noise levels was analyzed to determine the sensitivity of observers to changes in noise level. Individual detector measurements were shown to be normally distributed (p > 0.54), justifying the use of a Gaussian random noise generator for simulations. Phantom tests showed the ability to match original and simulated noise variance in the sinogram domain to within 5.6% +/- 1.6% (standard deviation), which was then propagated into the image domain with errors less than 4.1% +/- 1.6%. Cadaver measurements indicated that image noise was matched to within 2.6% +/- 2.0%. More importantly, the 4AFC observer studies indicated that the simulated images were realistic, i.e., no detectable difference between simulated and original images (p = 0.86) was observed. JND studies indicated that observers' sensitivity to change in noise levels corresponded to a 25% difference in dose, which is far larger than the noise accuracy achieved by simulation. In summary, the dose-reduction simulation tool demonstrated excellent accuracy in providing realistic images. The methodology promises to be a useful tool for researchers and radiologists to explore dose reduction protocols in an effort to produce diagnostic images with radiation dose "as low as reasonably achievable." (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3031114]
引用
收藏
页码:174 / 189
页数:16
相关论文
共 46 条
[1]  
Barrett H., 2004, FDN IMAGE SCI, P407
[2]   Quantum shot noise [J].
Beenakker, C ;
Schönenberger, C .
PHYSICS TODAY, 2003, 56 (05) :37-42
[3]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]   Addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: an example application to X-ray CT of the brain [J].
Britten, AJ ;
Crotty, M ;
Kiremidjian, H ;
Grundy, A ;
Adam, EJ .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (916) :323-328
[5]   COMPARISON OF RECEIVER OPERATING CHARACTERISTIC AND FORCED-CHOICE OBSERVER PERFORMANCE-MEASUREMENT METHODS [J].
BURGESS, AE .
MEDICAL PHYSICS, 1995, 22 (05) :643-655
[6]  
DAINTY JC, 1974, IMAGE SCI, P171
[7]   Preliminary validation of a new methodology for estimating dose reduction protocols in neonatal chest computed radiographs [J].
Don, Steven ;
Whiting, Bruce R. ;
Hildebolt, Charles F. ;
Sehnert, W. James ;
Ellinwood, Jacquelyn S. ;
Töpfer, Karin ;
Masoumzadeh, Parinaz ;
Krausa, Richard A. ;
Kronemer, Keith A. ;
Herman, Thomas ;
McAlister, William H. .
MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
[8]  
EARL OA, 2004, ELECT ENG
[9]  
ENGEL KJ, 2008, SPIE PHYS MED IMAGIN, V6913
[10]  
Fisher R. A., 1948, American Statistician, V2, P30, DOI DOI 10.2307/2681650