Segmenting brain white matter, gray matter and cerebro-spinal fluid using diffusion tensor-MRI derived indices

被引:17
作者
Cercignani, M
Inglese, M
Siger-Zajdel, M
Filippi, M [1 ]
机构
[1] San Raffaele Sci Inst, Dept Neurosci, Neuroimaging Res Unit, I-20132 Milan, Italy
[2] Univ Milan, Osped San Raffaele, I-20127 Milan, Italy
关键词
magnetic resonance imaging; diffusion tensor magnetic resonance imaging; fractional anisotropy; white matter; gray matter;
D O I
10.1016/S0730-725X(01)00457-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Based on its ability to provide quantitative information about tissue microstructure, diffusion tensor magnetic resonance imaging (DT-MRI) might be a valuable approach to improve the reliability of segmentation of the various brain tissues. In this study, a fully automated and easy-to-implement technique based on 2D histogram analysis of DT-MRI derived images was used to segment white and gray matter of the brain from 10 healthy subjects (aged = 27-56 years). The results obtained with this novel segmentation strategy were compared to those achieved by two experienced observers using an operator-dependent segmentation on the dual-echo scans. Visual inspection of the segmented tissues from a third senior observer disclosed that the automated technique worked properly on all images from all subjects and was more accurate than the human raters in defining thalamus white and gray matter portions as well as in tissue classification at the external brain edge. In addition, this segmentation technique resulted in an average gray/white matter ratio similar to that reported by post-mortem assessment. The application of the operator-dependent segmentation strategy was extremely time-consuming and the two observers achieved poorly reproducible results. Segmenting brain white and gray matter using information from DT-MRI proved to be an accurate approach with the potential for improving the understanding of the pathophysiology of many neurologic conditions. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:1167 / 1172
页数:6
相关论文
共 30 条
[1]   ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING [J].
ANDERSON, AW ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :379-387
[2]   TECHNICAL NOTE - INTENSITY CORRECTION IN SURFACE-COIL MR IMAGING [J].
AXEL, L ;
COSTANTINI, J ;
LISTERUD, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :418-420
[3]   METHODS AND THEORY OF RELIABILITY [J].
BARTKO, JJ ;
CARPENTER, WT .
JOURNAL OF NERVOUS AND MENTAL DISEASE, 1976, 163 (05) :307-317
[4]  
Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
[5]  
2-O
[6]   MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
BIOPHYSICAL JOURNAL, 1994, 66 (01) :259-267
[7]  
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
[8]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[9]   GRAPHICAL ANALYSIS OF MR FEATURE SPACE FOR MEASUREMENT OF CSF, GRAY-MATTER, AND WHITE-MATTER VOLUMES [J].
BONAR, DC ;
SCHAPER, KA ;
ANDERSON, JR ;
ROTTENBERG, DA ;
STROTHER, SC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (03) :461-470
[10]   Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes [J].
Butts, K ;
deCrespigny, A ;
Pauly, JM ;
Moseley, M .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :763-770