First clinical experience with a paclitaxel derivate-eluting polymer stent system implantation for in-stent restenosis - Immediate and long-term clinical and angiographic outcome

被引:149
作者
Liistro, F
Stankovic, G
Di Mario, C
Takagi, T
Chieffo, A
Moshiri, S
Montorfano, M
Carlino, M
Briguori, C
Pagnotta, P
Albiero, R
Corvaja, N
Colombo, A
机构
[1] Emo Centro Cuore Columbus Hosp, I-20145 Milan, Italy
[2] Osped San Raffaele, Catheterizat Labs, Milan, Italy
关键词
restenosis; stents; angiography;
D O I
10.1161/01.CIR.0000016042.69606.61
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-It has been shown that antiproliferative drugs such as paclitaxel lower the amount of intimal hyperplasia after stent implantation, We report the first clinical experience of 7-hexanoyltaxol (QP2)-eluting polymer stent system (QuaDS) implantation for in-stent restenosis. Methods and Results-Fifteen consecutive patients with elective indication to percutaneous coronary intervention for in-stent restenosis were treated with the QuaDS-QP2 stent implantation. The QuaDS-QP2 stent was successfully implanted in all but 2 target lesions. In one lesion, the restenotic segment could not be completely covered by the stent, and in another lesion, a bare metal stent was implanted distally to the QuaDS-QP2 stent. One patient suffered from postprocedural non-Q-wave myocardial infarction (NQWMI). No other adverse events were observed during hospital stay. Six- and 12-month angiographic and clinical follow-up was scheduled for all patients. At 6 months, 3 patients had target lesion revascularization (20%). Two patients had restenosis (13.3%); one experienced restenosis in a gap between 2 drug-eluting stents, and the other had stent occlusion leading to NQWMI. Minimal intimal hyperplasia was observed in all the segments covered by drug-eluting stents (late loss=0.47 +/- 1.01 mm with a loss index =0.17 +/- 0.39). At 12 months, I patient suffered from NQWMI, and 8 of 13 patients (61.5%) had angiographic restenosis (late loss= 1.36 +/- 0.94 nun with a loss index=0.62 +/- 0.44). Conclusion-This first experience with QuaDS-QP2 stent implantation for in-stent restenosis revealed minimal intimal hyperplasia at the 6-month follow-up. However, the antiproliferative effect was not maintained at the 12-month follow-up, resulting in delayed occurrence of angiographic restenosis.
引用
收藏
页码:1883 / 1886
页数:4
相关论文
共 13 条
  • [11] Angiographic patterns of in-stent restenosis - Classification and implications for long-term outcome
    Mehran, R
    Dangas, G
    Abizaid, AS
    Mintz, GS
    Lansky, AJ
    Satler, LF
    Pichard, AD
    Kent, KM
    Stone, GW
    Leon, MB
    [J]. CIRCULATION, 1999, 100 (18) : 1872 - 1878
  • [12] Mehran R, 1997, CIRCULATION, V96, P2183
  • [13] Catheter-based radiotherapy to inhibit restenosis after coronary stenting
    Teirstein, PS
    Massullo, V
    Jani, S
    Popma, JJ
    Mintz, GS
    Russo, RJ
    Schatz, RA
    Guarneri, EM
    Steuterman, S
    Morris, NB
    Leon, MB
    Tripuraneni, P
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (24) : 1697 - 1703