Mixture design in the optimization of a microemulsion system for the electrokinetic chromatographic determination of ketorolac and its impurities: Method development and validation

被引:36
作者
Furlanetto, S [1 ]
Orlandini, S [1 ]
Marras, AM [1 ]
Mura, P [1 ]
Pinzauti, S [1 ]
机构
[1] Univ Florence, Dept Pharmaceut Sci, I-50019 Florence, Italy
关键词
impurities; ketorolac; microemulsion electrokinetic chromatography;
D O I
10.1002/elps.200500507
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Microemulsion EKC (MEEKC) was used for the determination of ketorolac and its three impurities. The microemulsion system was optimized, for the first time in the literature, using a multivariate strategy involving a mixture design. A 13-run experimental plan covering an experimental domain defined by the components aqueous phase (10 mM borate buffer pH 9.2), oil phase (n-heptane) and surfactant/cosurfactant (SDS/n-butanol) was carried out. Good results were obtained with all microemulsions tested considering as responses analysis time and resolution, and according to the desirability function the best microemulsion system was constituted by 90.0% 10 mM borate buffer, 2.0% n-heptane, 8.0% of SDS/n-butanol in 1:2 ratio. Finally, with the aim of reducing analysis time, a response surface study was carried out in the experimental domain defined by the process variables temperature and voltage and the best values were 17 degrees C and -17 kV, respectively. Applying the optimised conditions, a complete resolution among the analytes was obtained in about 3 min using the short-end injection method. The method was validated for both drug substances and drug product and was applied to the quality control of ketorolac in coated tablets. A comparison of MEEKC, MEKC and CEC for assaying ketorolac and its related substances has been made.
引用
收藏
页码:805 / 818
页数:14
相关论文
共 57 条
[1]
QUANTITATIVE-DETERMINATION OF ORGANIC-SOLVENTS BY CAPILLARY ELECTROPHORESIS USING INDIRECT UV DETECTION [J].
ALTRIA, KD ;
HOWELLS, JS .
JOURNAL OF CHROMATOGRAPHY A, 1995, 696 (02) :341-348
[2]
Application of microemulsion electrokinetic chromatography to the analysis of a wide range of pharmaceuticals and excipients [J].
Altria, KD .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :371-386
[3]
THE APPLICATION OF EXPERIMENTAL-DESIGN TO THE ROBUSTNESS TESTING OF A METHOD FOR THE DETERMINATION OF DRUG-RELATED IMPURITIES BY CAPILLARY ELECTROPHORESIS [J].
ALTRIA, KD ;
FILBEY, SD .
CHROMATOGRAPHIA, 1994, 39 (5-6) :306-310
[4]
Background and operating parameters in microemulsion electrokinetic chromatography [J].
Altria, KD ;
Mahuzier, PE ;
Clark, BJ .
ELECTROPHORESIS, 2003, 24 (03) :315-324
[5]
Background theory and applications of microemulsion electrokinetic chromatography [J].
Altria, KD .
JOURNAL OF CHROMATOGRAPHY A, 2000, 892 (1-2) :171-186
[6]
Mixture and mixture process variable experiments for pharmaceutical applications [J].
Anderson-Cook, CM ;
Goldfarb, HB ;
Borror, CM ;
Montgomery, DC ;
Canter, KG ;
Twist, JN .
PHARMACEUTICAL STATISTICS, 2004, 3 (04) :247-260
[7]
[Anonymous], DESIGN OPTIMISATION
[8]
[Anonymous], [No title captured]
[9]
SIMULTANEOUS-OPTIMIZATION OF SEVERAL CHROMATOGRAPHIC PERFORMANCE GOALS USING DERRINGER DESIRABILITY FUNCTION [J].
BOURGUIGNON, B ;
MASSART, DL .
JOURNAL OF CHROMATOGRAPHY, 1991, 586 (01) :11-20
[10]
Brereton R. G., 2003, CHEMOMETRICS DATA AN