Long-term clinical results of tricuspid valve replacement

被引:126
作者
Chang, BC [1 ]
Lim, SH [1 ]
Yi, GY [1 ]
Hong, YS [1 ]
Lee, S [1 ]
Yoo, KJ [1 ]
Kang, MS [1 ]
Cho, BK [1 ]
机构
[1] Yonsei Univ, Coll Med, Severance Hosp, Cardovasc Ctr,Dept Thorac & Cardiovasc Surg, Seoul, South Korea
关键词
D O I
10.1016/j.athoracsur.2005.11.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Tricuspid valve replacement (TVR) has been performed with mechanical or bioprosthetic valves. However, the relative advantages of the two types are incompletely known. Methods. Between 1978 and 2003, we performed 138 TVR (35 bioprosthetic, 103 mechanical) in 125 patients (50 men, 75 women), with a mean age of 43.7 +/- 16.6 years. The diseases that required TVR were rheumatic (94), prosthetic valve failure (14), congenital (14), infective endocarditis(5), isolated tricuspid regurgitation (4), and miscellaneous conditions (7). The operations included the following: isolated TVR (41), double valve replacement (58), and triple valve replacement (39). The follow-up rate was 98.3%, and cumulative follow-up was 828.5 patient-years. Results. There were 22 in-hospital deaths (17.6%) and 13 (10.4%) late deaths. Fourteen patients required additional operations. There were 33 postoperative valve-related events including 11 thromboembolisms and 3 bleeding episodes. Kaplan-Meier survival for the entire group at 15 years was 73.8 +/- 8.5% (bioprosthetic: 70.2 +/- 10.4%, mechanical: 66.0 +/- 19.4%). At 15 years, freedom from reoperation was 66.3 +/- 9.4% (bioprosthetic: 55.1 +/- 13.8%, mechanical: 86.0 +/- 6.2%) and freedom from valve-related events was 49.9 +/- 8.0%. The linearized incidence of valve thrombosis was 1.28%/ patient-year (bioprosthetic: 0, mechanical: 1.92), anticoagulation-related bleeding was 0.37%/patient-year (mechanical: 0.54), reoperation was 1.71%/patient-year (bioprosthetic: 2.68, mechanical: 1.25), and valve-related events were 4.33%/patient-year (bioprosthetic: 3.83, mechanical: 4.6). Conclusions. Both bioprosthetic and mechanical valves revealed similar long-term outcomes. However, findings suggest that greater care is needed to prevent valve thrombosis in mechanical valves in the early postoperative period, and there is a greater chance for reoperation in bioprosthetic valves.
引用
收藏
页码:1317 / 1324
页数:8
相关论文
共 23 条
  • [1] TRICUSPID-VALVE REPLACEMENT WITH THE ST-JUDE MEDICAL VALVE
    AOYAGI, S
    NISHI, Y
    KAWARA, T
    ORYOJI, A
    HARA, H
    KOSUGA, K
    OHISHI, K
    [J]. SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1994, 24 (01): : 6 - 12
  • [2] Chang BC, 2001, J HEART VALVE DIS, V10, P185
  • [3] Dalrymple-Hay MJR, 1999, J HEART VALVE DIS, V8, P644
  • [4] Guidelines for reporting morbidity and mortality after cardiac valvular operations
    Edmunds, LH
    Clark, RE
    Cohn, LH
    Grunkemeier, GL
    Miller, C
    Weisel, RD
    [J]. ANNALS OF THORACIC SURGERY, 1996, 62 (03) : 932 - 935
  • [5] JUGDUTT BI, 1977, J THORAC CARDIOV SUR, V74, P20
  • [6] Prosthetic replacement of tricuspid valve: Bioprosthetic or mechanical
    Kaplan, M
    Kut, MS
    Demirtas, MM
    Cimen, S
    Ozler, A
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (02) : 467 - 473
  • [7] KAWACHI Y, 1992, J THORAC CARDIOV SUR, V104, P5
  • [8] Tricuspid valve replacement with the St. Jude Medical valve: 19 years of experience
    Kawano, H
    Oda, T
    Fukunaga, S
    Tayama, E
    Kawara, T
    Oryoji, A
    Aoyagi, S
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 18 (05) : 565 - 569
  • [9] Long-term results of porcine bioprostheses in the tricuspid position
    Kuwaki, K
    Komatsu, K
    Morishita, K
    Tsukamoto, M
    Abe, T
    [J]. SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1998, 28 (06): : 599 - 603
  • [10] MCGRATH LB, 1990, J THORAC CARDIOV SUR, V99, P124