Three dimensional CT angiography for patients with congenital heart disease: Scanning protocol for pediatric patients

被引:21
作者
Jelnin, V [1 ]
Co, J [1 ]
Muneer, B [1 ]
Swaminathan, B [1 ]
Toska, S [1 ]
Ruiz, CE [1 ]
机构
[1] Univ Illinois, Dept Pediat, Div Cardiol, Chicago, IL 60612 USA
关键词
computed tomography; cardiac anomalies; 3-D imaging; contrast injection rate; contrast enhancement level;
D O I
10.1002/ccd.20551
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The objective of our study was to determine the contrast attenuation level that yields high quality cardiac three-dimensional (3-D) images and to predict the contrast injection rate (IR), from body weight, to reach this attenuation level. Enhanced electron beam computerized tomography (EBCT) with 3-D reconstruction is useful in delineating cardiac anatomy in complex congenital heart disease (CHD). The current experience of using electron beam angiography (EBA) in pediatric CHD is limited. Well-defined contrast injection protocols, specifically the contrast IR, have not been standardized when compared to those for adults. Establishing the contrast IR is essential in obtaining high quality 3-D images. We retrospectively analyzed the studies of 115 pediatric patients with CHD. EBA images were divided into group 1 with good quality 3-D images and group 2 with poor quality. The mean of measured enhancement level, expressed in Hounsfield units (HU), and contrast IR were analyzed in both groups. Spearman correlation was used to examine the relationship between weight and IR. The IR was predicted from weight using simple linear regression analysis. The mean level of enhancement was 344 +/- 91 and 174 +/- 31 HU for group 1 and group 2, respectively. Group 1 consisted of 103 patients (90%) and the IR strongly correlated with weight (rho = 0.861, P < 0.01). The IR was estimated from the linear regression equation IR = 0.59 + 0.056 X weight. Necessary contrast enhancement level for quality 3-D reconstruction should be greater than 250 HU, and the IR can be estimated from patient's weight. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 25 条
[1]
PROPOSED DYNAMIC CARDIAC 3-D DENSITOMETER FOR EARLY DETECTION AND EVALUATION OF HEART-DISEASE [J].
BOYD, DP ;
GOULD, RG ;
QUINN, JR ;
SPARKS, R ;
STANLEY, JH ;
HERRMANNSFELDT, WB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2724-2726
[2]
BOYD DP, 1981, RADIOLOGY SKULL BRAI, V5, P4357
[3]
BOYD DP, 1983, CT HEART GREAT VESSE, P45
[4]
BRUNING I, 2001, 3D VIEWING AQUARIUS, P16
[5]
Intravenous three-dimensional coronary angiography using contrast enhanced electron beam computed tomography [J].
Budoff, MJ ;
Oudiz, RJ ;
Zalace, CP ;
Bakhsheshi, H ;
Goldberg, SL ;
French, WJ ;
Rami, TG ;
Brundage, BH .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (06) :840-845
[6]
Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography [J].
Budoff, MJ ;
Achenbach, S ;
Duerinckx, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) :1867-1878
[7]
GUNN V, 2002, HARRIET LANE HDB MAN, P440
[8]
ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality [J].
Hong, C ;
Becker, CR ;
Huber, A ;
Schoepf, UJ ;
Ohnesorge, B ;
Knez, A ;
Brüning, R ;
Reiser, MF .
RADIOLOGY, 2001, 220 (03) :712-717
[9]
HUSAYNI TS, 1992, ULTRAFAST COMPUTED T, P311
[10]
Knollmann FD, 2000, RADIOLOGY, V217, P374