Serial array of ISEs for use in a portable battery-powered flow injection analyzer

被引:44
作者
Dimitrakopoulos, T [1 ]
Alexander, PW [1 ]
Hibbert, DB [1 ]
机构
[1] UNIV NEW S WALES,DEPT ANALYT CHEM,SYDNEY,NSW 2052,AUSTRALIA
关键词
portable instrumentation; battery-powered; flow-injection potentiometry; array of ion-selective electrodes;
D O I
10.1002/elan.1140080507
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Portable flow injection potentiometry (FIP) is described with a flow-through multi-ion sensor array system based on a planar design. Potassium, sodium and nitrate sensors are used as examples for simultaneous multi-ion determinations based on the availability of a planar sensor design for these ions. The miniaturized flow cell developed with the three sensors in series in the FIP system is used to demonstrate the reliability of this portable design when using manual injection of the sample solution. The system is characterized by its small size, light weight and low power requirements, and makes use of a notebook computer for real-time display of data and data acquisition. Rapid FIP response characteristics are shown after optimization of flow carrier conditions, and are successfully applied to the analysis of mineral water samples.
引用
收藏
页码:438 / 442
页数:5
相关论文
共 28 条
  • [1] Andrew Kevin N., 1994, Analytical Chemistry, V66, p917A
  • [2] SPARINGLY SELECTIVE ION-SELECTIVE ELECTRODE ARRAYS FOR MULTICOMPONENT ANALYSIS
    BEEBE, K
    UERZ, D
    SANDIFER, J
    KOWALSKI, B
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (01) : 66 - 71
  • [3] NONLINEAR CALIBRATION USING PROJECTION PURSUIT REGRESSION - APPLICATION TO AN ARRAY OF ION-SELECTIVE ELECTRODES
    BEEBE, KR
    KOWALSKI, BR
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (20) : 2273 - 2278
  • [4] FLOW CELL WITH DOUBLE SLOPE FACTOR FOR POTENTIOMETRIC DETERMINATION OF FLUORIDE AT LOW CONCENTRATIONS
    BORZITSKY, JA
    DVININ, A
    PETRUKHIN, OM
    URUSOV, YI
    [J]. ANALYST, 1993, 118 (07) : 859 - 861
  • [5] A MULTI-ION SENSOR CELL AND DATA-ACQUISITION SYSTEM FOR FLOW-INJECTION ANALYSIS
    CARDWELL, TJ
    CATTRALL, RW
    HAUSER, PC
    HAMILTON, IC
    [J]. ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) : 359 - 366
  • [6] AMMONIUM DETECTION USING AN ION-SELECTIVE ELECTRODE ARRAY IN FLOW-INJECTION ANALYSIS
    DEVITERI, FJS
    DIAMOND, D
    [J]. ELECTROANALYSIS, 1994, 6 (01) : 9 - 16
  • [7] MULTICOMPONENT BATCH-INJECTION ANALYSIS USING AN ARRAY OF ION-SELECTIVE ELECTRODES
    DIAMOND, D
    LU, JM
    CHEN, Q
    WANG, J
    [J]. ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 629 - 635
  • [8] ROBUST ESTIMATION OF SELECTIVITY COEFFICIENTS USING MULTIVARIATE CALIBRATION OF ION-SELECTIVE ELECTRODE ARRAYS
    DIAMOND, D
    FORSTER, RJ
    [J]. ANALYTICA CHIMICA ACTA, 1993, 276 (01) : 75 - 86
  • [9] A portable flow injection analyzer for use with ion-selective electrodes
    Dimitrakopoulos, T
    Alexander, PW
    Hibbert, DB
    Cherkson, L
    Morgan, J
    [J]. ELECTROANALYSIS, 1995, 7 (12) : 1118 - 1120
  • [10] NONLINEAR CALIBRATION OF ION-SELECTIVE ELECTRODE ARRAYS FOR FLOW-INJECTION ANALYSIS
    FORSTER, RJ
    DIAMOND, D
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (15) : 1721 - 1728