High resolution MR perfusion imaging of the kidneys at 3 Tesla without administration of contrast media

被引:36
作者
Boss, A [1 ]
Martirosian, P [1 ]
Graf, H [1 ]
Claussen, CD [1 ]
Schlemmer, HP [1 ]
Schick, F [1 ]
机构
[1] Radiol Univ Klin, Abt Radiol Diagnost, D-72076 Tubingen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2005年 / 177卷 / 12期
关键词
MR diffusion/perfusion; kidney; high field;
D O I
10.1055/s-2005-858761
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The feasibility of high-resolution arterial spin labeling (ASL) perfusion imaging of the kidneys was tested and proven at 3 Tesla using a flow-sensitive alternating inversion recovery (FAIR) true fast imaging in steady precession (TrueFISP) technique. Materials and Methods: Kidney perfusion maps of six healthy volunteers and two patients were acquired using a clinical 3-Tesla whole-body scanner. An ASL sequence with FAIR spin preparation and a TrueFISP signal detection strategy was adapted for high-resolution perfusion imaging of the kidneys at 3 Tesla. To avoid banding artifacts in TrueFISP images, which are generally prominent at 3 Tesla, a frequency scout was implemented. Perfusion maps with an in-plane resolution of 1.5 mm were recorded in transverse and coronal orientation. For fast mapping of whole-kidney perfusion, an in-plane resolution of 2 mm was applied. Results: In all volunteers and patients, high-resolution perfusion images with excellent image quality were able to be obtained in a measuring time of approximately 10 minutes. The whole kidney was able to be mapped with good image quality in less than 10 minutes. For all slices, a suitable frequency offset made it possible to reproduce the kidneys without TrueFISP artifacts. Perfusion values of the renal cortex ranged from 250 ml/100 g/min up to 400 ml/100 g/min (mean cortical perfusion right kidney 316 43, left 336 40). Conclusion: High-resolution ASL perfusion images of the whole kidney were able to be obtained with good image quality by means of a 3 Tesla MR setting within a clinically applicable measuring time, thus providing an alternative to conventional perfusion imaging involving potentially nephrotoxic contrast media.
引用
收藏
页码:1625 / 1630
页数:6
相关论文
共 16 条
[1]   Measuring cerebral blood flow using magnetic resonance imaging techniques [J].
Calamante, F ;
Thomas, DL ;
Pell, GS ;
Wiersma, J ;
Turner, R .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1999, 19 (07) :701-735
[2]   STAR-HASTE: Perfusion imaging without magnetic susceptibility artifact [J].
Chen, Q ;
Siewert, B ;
Bly, BM ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :404-408
[3]   MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results [J].
de Bazelaire, CMJ ;
Duhamel, GD ;
Rofsky, NM ;
Alsop, DC .
RADIOLOGY, 2004, 230 (03) :652-659
[4]   Gadolinium-based contrast media compared with iodinated media for digital subtraction angiography in azotaemic patients [J].
Erley, CM ;
Bader, BD ;
Berger, ED ;
Tuncel, N ;
Winkler, S ;
Tepe, G ;
Risler, T ;
Duda, S .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2004, 19 (10) :2526-2531
[5]   MR-based methods of the functional imaging of the CNS [J].
Giesel, FL ;
Wüstenberg, T ;
Bongers, A ;
Weber, MA ;
Zechmann, C ;
Baudendistel, KT ;
von Tengg-Kobligk, H ;
Hahn, HK .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (05) :714-730
[6]   FAST MR-IMAGING - TECHNIQUES AND CLINICAL-APPLICATIONS [J].
HAACKE, EM ;
TKACH, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :951-964
[7]   Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE [J].
Karger, N ;
Biederer, J ;
Lüsse, S ;
Grimm, J ;
Steffens, JC ;
Heller, M ;
Glüer, CC .
MAGNETIC RESONANCE IMAGING, 2000, 18 (06) :641-647
[8]   QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING [J].
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :293-301
[9]  
Luh WM, 1999, MAGNET RESON MED, V41, P1246, DOI 10.1002/(SICI)1522-2594(199906)41:6<1246::AID-MRM22>3.0.CO
[10]  
2-N