Validation of conductance catheter system for quantification of murine pressure-volume loops

被引:42
作者
Yang, B
Larson, DF
Beischel, J
Kelley, R
Shi, J
Watson, RR
机构
[1] Univ Arizona, Coll Med, Dept Surg, Sarver Heart Ctr, Tucson, AZ 85724 USA
[2] Univ Arizona, Coll Med, Arizona Prevent Ctr, Tucson, AZ 85724 USA
关键词
conductance; ESPVR; hemodynamics; mouse; PRSW; ventricular function; ventricular mechanics;
D O I
10.1080/089419301753435710
中图分类号
R61 [外科手术学];
学科分类号
摘要
The purpose of this study was to define the validation methods and outcomes of a conductance catheter system specifically for in vivo murine cardiac hemodynamic analysis. To express the relationship between conductance and blood volumes, we used an in vitro model to derive a volume-conductance line. The volume-conductance line was used to compute raw volume from the modified conductance signals. The parallel volume was calibrated with hypertonic (15%) saline injected from extrajugular vein. The ventricular volume was computed by raw volume minus parallel volume. The accuracy of conductance volumetric measurements was validated with a static in situ infusion of calibrated volumes of whole blood injected into arrested left ventricles. In vivo dynamic measurements were performed with 24 C57B1/6 mice, 6 months old; for comparison of established values. The in situ model showed that after calibration, the experimental coefficient, alpha, was equal to 1 and the measured volume by conductance catheter was equal to the true volume of the left ventricle (y=0.982x + 0.513, p<.0001). For the in vivo models, the end-diastolic volumes and the stroke volumes and cardiac output determined with the conductance catheter system were 17.3±1.0 μL, 10.6±0.9 μL, and 6.0±0.5 mL/min, respectively. We validated the relationship between measured volume by conductance catheter and the true volume and demonstrated the accuracy of the volume-conductance line for conversion of conductance to volume.
引用
收藏
页码:341 / 355
页数:15
相关论文
共 26 条
[1]   Targeting the receptor-Gq interface to inhibit in vivo pressure overload myocardial hypertrophy [J].
Akhter, SA ;
Luttrell, LM ;
Rockman, HA ;
Iaccarino, G ;
Lefkowitz, RJ ;
Koch, WJ .
SCIENCE, 1998, 280 (5363) :574-577
[2]   SIMULTANEOUS CONDUCTANCE CATHETER AND DIMENSION ASSESSMENT OF LEFT-VENTRICLE VOLUME IN THE INTACT ANIMAL [J].
APPLEGATE, RJ ;
CHENG, CP ;
LITTLE, WC .
CIRCULATION, 1990, 81 (02) :638-648
[3]   CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER [J].
BAAN, J ;
VANDERVELDE, ET ;
DEBRUIN, HG ;
SMEENK, GJ ;
KOOPS, J ;
VANDIJK, AD ;
TEMMERMAN, D ;
SENDEN, J ;
BUIS, B .
CIRCULATION, 1984, 70 (05) :812-823
[4]   CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER [J].
BAAN, J ;
JONG, TTA ;
KERKHOF, PLM ;
MOENE, RJ ;
VANDIJK, AD ;
VANDERVELDE, ET ;
KOOPS, J .
CARDIOVASCULAR RESEARCH, 1981, 15 (06) :328-334
[5]   Validation of a mouse conductance system to determine LV volume: comparison to echocardiography and crystals [J].
Feldman, MD ;
Erikson, JM ;
Mao, Y ;
Korcarz, CE ;
Lang, RM ;
Freeman, GL .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (04) :H1698-H1707
[6]   Magnetic resonance imaging and invasive evaluation of development of heart failure in transgenic mice with myocardial expression of tumor necrosis factor-α [J].
Franco, F ;
Thomas, GD ;
Giroir, B ;
Bryant, D ;
Bullock, MC ;
Chwialkowski, MC ;
Victor, RG ;
Peshock, RM .
CIRCULATION, 1999, 99 (03) :448-454
[7]   Estimation of parallel conductance by dual-frequency conductance catheter in mice [J].
Georgakopoulos, D ;
Kass, DA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (01) :H443-H450
[8]   In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry [J].
Georgakopoulos, D ;
Mitzner, WA ;
Chen, CH ;
Byrne, BJ ;
Millar, HD ;
Hare, JM ;
Kass, DA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (04) :H1416-H1422
[9]  
Grimm PC, 1999, J AM SOC NEPHROL, V10, P1582
[10]   Murine cardiac function - A cautionary tail [J].
Kass, DA ;
Hare, JM ;
Georgakopoulos, D .
CIRCULATION RESEARCH, 1998, 82 (04) :519-522