Estimation of parallel conductance by dual-frequency conductance catheter in mice

被引:65
作者
Georgakopoulos, D
Kass, DA
机构
[1] Johns Hopkins Med Inst, Dept Med, Div Cardiol, Baltimore, MD 21287 USA
[2] Johns Hopkins Med Inst, Dept Biomed Engn, Baltimore, MD 21287 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2000年 / 279卷 / 01期
关键词
mouse; hemodynamics; ventricular function; methods;
D O I
10.1152/ajpheart.2000.279.1.H443
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The conductance catheter method has substantially enhanced the characterization of in vivo cardiovascular function in mice. Absolute volume determination requires assessment of parallel conductance (V-p) offset because of conductivity of structures external to the blood pool. Although such a determination is achievable by hypertonic saline bolus injection, this method poses potential risks to mice because of volume loading and/or contractility changes. We tested another method based on differences between blood and muscle conductances at various catheter excitation frequencies (20 vs. 2 kHz) in 33 open-chest mice. The ratio of mean frequency-dependent signal difference to V-p derived by hypertonic saline injection was consistent [0.095 +/- 0.01 (SD), n = 11], and both methods were strongly correlated (r(2) = 0.97, P< 0.0001). This correlation persisted when the ratio was prospectively applied to a separate group of animals (n = 12), with a combined regression relation of V-p(DF) = 1.1 * V-p(Sal) - 2.5 [where V-p(DF) is V-p derived by the dual-frequency method and V-p(Sal) is V-p derived by hypertonic saline bolus injection], r(2) = 0.95, standard error of the estimate = 1.1 mu l, and mean difference = 0.6 +/- 1.4 mu l. Varying V-p(Sal) in a given animal resulted in parallel changes in V-p(DF) (multiple regression r(2) = 0.92, P< 0.00001). The dominant source of V-p in mice was found to be the left ventricular wall itself, since surrounding the heart in the chest with physiological saline or markedly varying right ventricular volumes had a minimal effect on the left ventricular volume signal. On the basis of V-p and flow probe-derived cardiac output, end-diastolic volume and ejection fraction in normal mice were 28 +/- 3 mu l and 81 +/- 6%, respectively, at a heart rate of 622 +/- 28 min(-1). Thus the dual-frequency method and independent flow signal can be used to provide absolute volumes in mice.
引用
收藏
页码:H443 / H450
页数:8
相关论文
共 26 条
  • [1] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN RABBIT, USING A 2-ELECTRODE CATHETER
    ABE, S
    OHTOMO, J
    YAMAGUCHI, I
    TSUCHIDA, E
    FUJINUMA, T
    SUNAGAWA, K
    TOMOIKE, H
    [J]. HEART AND VESSELS, 1995, 10 (03) : 138 - 145
  • [2] SIMULTANEOUS CONDUCTANCE CATHETER AND DIMENSION ASSESSMENT OF LEFT-VENTRICLE VOLUME IN THE INTACT ANIMAL
    APPLEGATE, RJ
    CHENG, CP
    LITTLE, WC
    [J]. CIRCULATION, 1990, 81 (02) : 638 - 648
  • [3] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [4] CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER
    BAAN, J
    JONG, TTA
    KERKHOF, PLM
    MOENE, RJ
    VANDIJK, AD
    VANDERVELDE, ET
    KOOPS, J
    [J]. CARDIOVASCULAR RESEARCH, 1981, 15 (06) : 328 - 334
  • [5] MICROSPHERE AND DILUTION TECHNIQUES FOR THE DETERMINATION OF BLOOD FLOWS AND VOLUMES IN CONSCIOUS MICE
    BARBEE, RW
    PERRY, BD
    RE, RN
    MURGO, JP
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (03): : R728 - R733
  • [6] Cabreriza SE, 1997, ASAIO J, V43, pM509
  • [7] Cardiovascular phenotyping in mice
    Doevendans, PA
    Daemen, MJ
    de Muinck, ED
    Smits, JF
    [J]. CARDIOVASCULAR RESEARCH, 1998, 39 (01) : 34 - 49
  • [8] ESTIMATING LEFT-VENTRICULAR OFFSET VOLUME USING DUAL-FREQUENCY CONDUCTANCE CATHETERS
    GAWNE, TJ
    GRAY, KS
    GOLDSTEIN, RE
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (02) : 872 - 876
  • [9] The pathogenesis of familial hypertrophic cardiomyopathy:: Early and evolving effects from an α-cardiac myosin heavy chain missense mutation
    Georgakopoulos, D
    Christe, ME
    Giewat, M
    Seidman, CM
    Seidman, JG
    Kass, DA
    [J]. NATURE MEDICINE, 1999, 5 (03) : 327 - 330
  • [10] GEORGAKOPOULOS D, 1998, AM J PHYSIOL-HEART C, V274, P1416