Amperometric monitoring of lactate accumulation in rabbit ischemic myocardium

被引:36
作者
Marzouk, SAM
Cosofret, VV
Buck, RP
Yang, H
Cascio, WE
Hassan, SSM
机构
[1] UNIV N CAROLINA,DEPT CHEM,CHAPEL HILL,NC 27599
[2] UNIV N CAROLINA,DEPT MED,CHAPEL HILL,NC 27599
[3] AIN SHAMS UNIV,DEPT CHEM,CAIRO,EGYPT
基金
美国国家卫生研究院;
关键词
amperometric biosensors; ischemia; lactate monitoring; papillary muscle;
D O I
10.1016/S0039-9140(96)02175-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fabrication and characterization of miniature, flexible, planar biosensors for monitoring L-lactate accumulation in an ischemic myocardium are described. Three configurations of Au-based electrodes were fabricated by a photolithographic technique on flexible polyimide Kapton(R) foil. All sensors are based on an immobilized lactate oxidase with amperometric detection of the enzymatically produced hydrogen peroxide al a platinum-electroplated-gold base electrode polarized at 0.5 V versus Ag/AgCl. An inner electropolymeric layer is used to prevent electrode fouling and to reject the interference effects of easily oxidizable molecules. In addition, a diffusion controlling outer layer that greatly enhances the linear dynamic range of the sensor, is obtained by casting a polyurethane external film. The developed sensor was evaluated in vitro and proved to have high selectivity, good operational stability, good accuracy and precision (average recovery = 102.3 +/- 0.4% for control sera), fast response time (t(95) = 20 s) and high upper limit of the linear dynamic range (25-80 mM, with sensitivity of 1.7-0.4 nA mM(-1), respectively at PO2 = 15 mmHg). Subsequently, the sensor was brought into direct contact with the surface of the rabbit papillary muscle and used for continuous quantitative monitoring of extracellular lactate accumulation during no-flow ischemia. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1527 / 1541
页数:15
相关论文
共 45 条
[11]   A NEEDLE-TYPE ENZYME-BASED LACTATE SENSOR FOR IN-VIVO MONITORING [J].
HU, YB ;
ZHANG, YN ;
WILSON, GS .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :503-511
[12]   TRANSCUTANEOUS LACTATE MONITORING BASED ON A MICRO-PLANAR AMPEROMETRIC BIOSENSOR [J].
ITO, N ;
MATSUMOTO, T ;
FUJIWARA, H ;
MATSUMOTO, Y ;
KAYASHIMA, S ;
ARAI, T ;
KIKUCHI, M ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1995, 312 (03) :323-328
[13]  
KABAYASHI K, 1979, CIRC RES, V44, P166
[14]   MICROBIOASSAY OF PHENYLALANINE IN BLOOD SERA WITH A LACTATE ELECTRODE [J].
KARUBE, I ;
MATSUNAGA, T ;
TERAOKA, N ;
SUZUKI, S .
ANALYTICA CHIMICA ACTA, 1980, 119 (02) :271-276
[15]   ELECTRICAL CONSTANTS OF ARTERIALLY PERFUSED RABBIT PAPILLARY-MUSCLE [J].
KLEBER, AG ;
RIEGGER, CB .
JOURNAL OF PHYSIOLOGY-LONDON, 1987, 385 :307-324
[17]   MINIATURE ELECTROCHEMICAL GLUCOSE BIOSENSORS [J].
KOUDELKAHEP, M ;
STRIKE, DJ ;
DEROOIJ, NF .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :461-466
[18]   L-LACTATE OXIDASE ELECTRODE BASED ON METHYLENE GREEN AND CARBON PASTE [J].
KULYS, J ;
WANG, LZ ;
MAKSIMOVIENE, A .
ANALYTICA CHIMICA ACTA, 1993, 274 (01) :53-58
[19]   REAGENTLESS LACTATE SENSOR BASED ON CYTOCHROME-B2 [J].
KULYS, JJ ;
SVIRMICKAS, GJS .
ANALYTICA CHIMICA ACTA, 1980, 117 (JUN) :115-120
[20]  
LIU HY, 1995, ANAL LETT, V28, P563