Correlation at fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes

被引:137
作者
Garg, SK
Potts, RO
Ackerman, NR
Fermi, SJ
Tamada, JA
Chase, HP
机构
[1] Univ Colorado, Hlth Sci Ctr, Barbara Davis Ctr Childhood Diabet, Dept Pediat, Denver, CO 80262 USA
[2] Univ Colorado, Hlth Sci Ctr, Barbara Davis Ctr Childhood Diabet, Dept Med, Denver, CO 80262 USA
[3] Cygnus Inc, Redwood City, CA USA
关键词
D O I
10.2337/diacare.22.10.1708
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - The purpose of this study was to compare measurements of glucose obtained via iontophoretic extraction with the GlucoWatch automatic glucose biographer (Cygnus, Inc., Redwood City CA) with capillary blood glucose values that were determined 1) in a controlled outpatient clinic setting and 2) in a home setting. RESEARCH DESIGN AND METHODS - There were 76 GlucoWatch biographers used on 28 different young adults (21 women and 7 men) with type 1 diabetes (age 30.9 +/- 6.9 years and duration of diabetes 18.4 +/- 8.1 years [mean +/- SD]) in a controlled outpatient clinic setting. Some subjects participated on multiple days. Subjects wore two GlucoWatch biographers, each on the forearm (ventral aspect). Comparisons were made to HemoCue blood glucose analyzer (Aktiebolgat Leo, Helsingborg, Sweden) capillary blood glucose measurements, In addition, Gluco-Watch biographers (one each day for 3 consecutive days) were used by 12 subjects (8 women, 4 men) in a home setting. Comparisons were made to capillary blood glucose values determined using the One Touch Profile meter (Johnson & Johnson, Nem Brunswick, NJ). RESULTS - GlucoWatch biographer glucose values correlated well with capillary blood glucose values determined using the HemoCue analyzer in the clinic setting (r = 0.90, 1,554 paired data points) and using the One Touch Profile meter in the home setting (r = 0.85, 204 paired data points). When 36 subjects wore two biographers simultaneously, the correlation between the two biographers was r = 0.94. The error grid analysis demonstrated that >96% of biographer glucose values determined in the clinic or home setting were in the clinically acceptable A and B regions. CONCLUSIONS - This study confirms the accuracy and precision of glucose values as determined using the GlucoWatch biographer in clinic and home settings.
引用
收藏
页码:1708 / 1714
页数:7
相关论文
共 15 条
  • [1] Validation of home blood glucose meters with respect to clinical and analytical approaches
    Brunner, GA
    Ellmerer, M
    Sendlhofer, G
    Wutte, A
    Trajanoski, Z
    Schaupp, L
    Quehenberger, F
    Wach, P
    Krejs, GJ
    Pieber, TR
    [J]. DIABETES CARE, 1998, 21 (04) : 585 - 590
  • [2] EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE
    CLARKE, WL
    COX, D
    GONDERFREDERICK, LA
    CARTER, W
    POHL, SL
    [J]. DIABETES CARE, 1987, 10 (05) : 622 - 628
  • [3] Diabetes Control and Complications Trial Research Group, 1993, NEW ENGL J MED, V329, P997
  • [4] Draize JH, 1944, J PHARMACOL EXP THER, V82, P377
  • [5] NONINVASIVE SAMPLING OF BIOLOGICAL-FLUIDS BY IONTOPHORESIS
    GLIKFELD, P
    HINZ, RS
    GUY, RH
    [J]. PHARMACEUTICAL RESEARCH, 1989, 6 (11) : 988 - 990
  • [6] A WARD COMPARISON BETWEEN THE ONE TOUCH-II AND GLUCOMETER-II BLOOD-GLUCOSE METERS
    KILPATRICK, ES
    MCLEOD, MJ
    RUMLEY, AG
    SMALL, M
    [J]. DIABETIC MEDICINE, 1994, 11 (02) : 214 - 217
  • [7] KURNIK RT, 1997, Patent No. 24059
  • [8] MARSHALL G, 1993, OPHTHALMOLOGY, V100, P1133
  • [9] *MICR CORP, MICR EXC 97 SR 1
  • [10] INTENSIVE INSULIN THERAPY PREVENTS THE PROGRESSION OF DIABETIC MICROVASCULAR COMPLICATIONS IN JAPANESE PATIENTS WITH NON-INSULIN-DEPENDENT DIABETES-MELLITUS - A RANDOMIZED PROSPECTIVE 6-YEAR STUDY
    OHKUBO, Y
    KISHIKAWA, H
    ARAKI, E
    MIYATA, T
    ISAMI, S
    MOTOYOSHI, S
    KOJIMA, Y
    FURUYOSHI, N
    SHICHIRI, M
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 1995, 28 (02) : 103 - 117