Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography

被引:79
作者
Dietrich, Tobias J. [1 ,2 ]
Pfirrmann, Christian W. A. [1 ,2 ]
Schwab, Alexander [2 ,3 ]
Pankalla, Katja [1 ,2 ]
Buck, Florian M. [1 ,2 ]
机构
[1] Orthoped Univ Hosp Balgrist, Dept Radiol, CH-8008 Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
[3] Orthoped Univ Hosp Balgrist, Dept Finances, CH-8008 Zurich, Switzerland
关键词
Digital radiography; Radiation dosage; Workflow; Financial management; IMAGING-SYSTEM; 3D;
D O I
10.1007/s00256-013-1600-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
To compare the radiation dose, workflow, patient comfort, and financial break-even of a standard digital radiography and a biplanar low-dose X-ray system. A standard digital radiography system (Ysio, Siemens Healthcare, Erlangen, Germany) was compared with a biplanar X-ray unit (EOS, EOS imaging, Paris, France) consisting of two X-ray tubes and slot-scanning detectors, arranged at an angle of 90A degrees allowing simultaneous vertical biplanar linear scanning in the upright patient position. We compared data of standing full-length lower limb radiographs and whole spine radiographs of both X-ray systems. Dose-area product was significantly lower for radiographs of the biplanar X-ray system than for the standard digital radiography system (e.g. whole spine radiographs; standard digital radiography system: 392.2 +/- 231.7 cGy*cm(2) versus biplanar X-ray system: 158.4 +/- 103.8 cGy*cm(2)). The mean examination time was significantly shorter for biplanar radiographs compared with standard digital radiographs (e.g. whole spine radiographs: 449 s vs 248 s). Patients' comfort regarding noise was significantly higher for the standard digital radiography system. The financial break-even point was 2,602 radiographs/year for the standard digital radiography system compared with 4,077 radiographs/year for the biplanar X-ray unit. The biplanar X-ray unit reduces radiation exposure and increases subjective noise exposure to patients. The biplanar X-ray unit demands a higher number of examinations per year for the financial break-even point, despite the lower labour cost per examination due to the shorter examination time.
引用
收藏
页码:959 / 967
页数:9
相关论文
共 26 条
[1]
Urethrography in Men: Conventional Technique versus Clamp Method [J].
Berna-Mestre, Juan D. ;
Berna-Serna, Juan D. ;
Aparicio-Meson, Martin ;
Canteras-Jordana, Manuel .
RADIOLOGY, 2009, 252 (01) :240-246
[2]
Femoral and Tibial Torsion Measurements With 3D Models Based on Low-Dose Biplanar Radiographs in Comparison With Standard CT Measurements [J].
Buck, Florian M. ;
Guggenberger, Roman ;
Koch, Peter P. ;
Pfirrmann, Christian W. A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :W607-W612
[3]
Diagnostic Imaging of Spinal Deformities Reducing Patients Radiation Dose With a New Slot-Scanning X-ray Imager [J].
Deschenes, Sylvain ;
Charron, Guy ;
Beaudoin, Gilles ;
Labelle, Hubert ;
Dubois, Josee ;
Miron, Marie-Claude ;
Parent, Stefan .
SPINE, 2010, 35 (09) :989-994
[4]
Physical characteristics of a low-dose gas microstrip detector for orthopedic x-ray imaging [J].
Després, P ;
Beaudoin, G ;
Gravel, P ;
de Guise, JA .
MEDICAL PHYSICS, 2005, 32 (04) :1193-1204
[5]
A new 2D and 3D imaging approach to musculo-skeletal physiology and pathology with low-dose radiation and the standing position : the EOS system [J].
Dubousset, J ;
Charpak, G ;
Dorion, I ;
Skalli, W ;
Lavaste, F ;
Deguise, J ;
Kalifa, G ;
Ferey, S .
BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2005, 189 (02) :287-297
[6]
Personalized body segment parameters from biplanar low-dose radiography [J].
Dumas, R ;
Aissaoui, R ;
Mitton, D ;
Skalli, W ;
de Guise, JA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (10) :1756-1763
[7]
Patient comfort in periapical examination using digital receptors [J].
Goncalves, A. ;
Wiezel, V. G. ;
Goncalves, M. ;
Hebling, J. ;
Sannomiya, E. K. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (07) :484-488
[8]
Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1 [J].
Illers, H ;
Buhr, E ;
Hoeschen, C .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :39-44
[9]
Breakthrough in three-dimensional scoliosis diagnosis: significance of horizontal plane view and vertebra vectors [J].
Illes, Tamas ;
Tunyogi-Csapo, Miklos ;
Somoskeoey, Szabolcs .
EUROPEAN SPINE JOURNAL, 2011, 20 (01) :135-143
[10]
Advances in digital radiography:: Physical principles and system overview [J].
Koerner, Markus ;
Weber, Christof H. ;
Wirth, Stefan ;
Pfeifer, Klaus-Juergen ;
Reiser, Maximilian F. ;
Treitl, Marcus .
RADIOGRAPHICS, 2007, 27 (03) :675-686