Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1

被引:48
作者
Illers, H
Buhr, E
Hoeschen, C
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[2] Univ Hosp Magdeburg, Dept Diagnost Radiol, D-39120 Magdeburg, Germany
关键词
D O I
10.1093/rpd/nch507
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
A mobile measurement facility which complies with IEC 62220-1 has been set up to determine the detective quantum efficiency (DQE) of digital X-ray detector systems. Exemplary measurements were performed for two similar CR detector systems, a CsI-based indirect detector and an Se-based direct detector. The standardised radiation quality RQA 5 was applied for measurement and for three of these systems RQA 9 was also applied. A pronounced dependence of DQE on radiation quality was observed for the direct detector, where the DQEs for RQA 5 and RQA 9 differ by a factor of similar to 2. The uncertainty (95% confidence interval) associated with the measured DQE values is within 0.01 and 0.04 depending on, for example, the spatial frequency. Thus, it has been demonstrated that the DQE can be measured accurately and reliably with the accuracy required by the international standard TEC 62220-1. It is now possible to objectively measure and compare DQE values of digital X-ray detector systems.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 12 条
[1]
Evaluation of the imaging properties of two generations of a CCD-based system for digital chest radiography [J].
Båth, M ;
Sund, P ;
Månsson, LG .
MEDICAL PHYSICS, 2002, 29 (10) :2286-2297
[2]
Simple method for modulation transfer function determination of digital imaging detectors from edge images [J].
Buhr, E ;
Günther-Kohfahl, S ;
Neitzel, U .
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 :877-884
[3]
Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image [J].
Buhr, E ;
Günther-Kohfahl, S ;
Neitzel, U .
MEDICAL PHYSICS, 2003, 30 (09) :2323-2331
[4]
Cunningham I. A., 2000, HDB MED IMAGING, V1, P79
[5]
DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES [J].
DOBBINS, JT ;
ERGUN, DL ;
RUTZ, L ;
HINSHAW, DA ;
BLUME, H ;
CLARK, DC .
MEDICAL PHYSICS, 1995, 22 (10) :1581-1593
[6]
Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications [J].
Granfors, PR ;
Aufrichtig, R .
MEDICAL PHYSICS, 2000, 27 (06) :1324-1331
[7]
ILERS H, 2004, P SPIE MED IMAGING 2, V5368, P639
[8]
Measurement of the Detective Quantum Efficiency (DQE) of digital X-ray imaging devices according to the standard IEC 62220-1 [J].
Illers, H ;
Buhr, E ;
Bergmann, D ;
Hoeschen, C .
MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 :177-187
[9]
*INT EL COMM, 1994, MED DIAGN XRAY EQ RA
[10]
*INT EL COMM, 2003, MED EL EQ CHAR DI XR