Evaluation of the imaging properties of two generations of a CCD-based system for digital chest radiography

被引:35
作者
Båth, M [1 ]
Sund, P
Månsson, LG
机构
[1] Gothenburg Univ, Sahlgrens Hosp, Dept Radiat Phys, S-41345 Gothenburg, Sweden
[2] Sahlgrenska Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
关键词
digital radiography (DR); modulation transfer function (MTF); detective quantum efficiency (DQE); image quality; CCD;
D O I
10.1118/1.1507781
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two generations of a CCD-based detector system with lens-based optical coupling for digital chest radiography were evaluated in terms of presampling MTF, NPS, NEQ, DQE, linearity in response, and SNR over the detector area. Measurements were performed over a wide exposure range and at several different beam qualities. Neither the presampling MTF nor the DQE showed any general strong beam quality dependence, whereas the NPS and NEQ did when compared at specific entrance air kerma values. The exposure dependency for the DQE was found to be considerable, with the detectors showing low DQE at low exposures, and higher DQE at higher exposures. It was found that the second generation has been substantially improved compared to its predecessor regarding all the relevant parameters. The DQE(0) at an entrance air kerma of 5 muGy increased from 9% to 15%, mainly due to a better system gain (including optical coupling efficiency and matching of the energy of the emitted light photons to the sensitivity of the CCD camera). The first generation of detectors was found to have problems with bad peripheral resolution [MTF(mu(N)/2) <0.1]. This problem was nonexistent for the second generation for which uniform resolution has been obtained [MTF(μ(N)/2) = 0.3]. A theoretical calculation of the DQE of two model systems similar to the ones evaluated was also performed, and the results were comparable to the experimentally determined data at high exposures. The model shows that both systems suffer from low optical coupling efficiency due to the large demagnification used. The main conclusion is that although the second generation has been improved, there is still a problem with low system gain leading to relatively modest DQE values, especially at low exposures. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:2286 / 2297
页数:12
相关论文
共 28 条
[1]   Method for determining the two-dimensional presampling modulation transfer function in digital radiography [J].
Båth, M ;
Sund, P ;
Månsson, LG .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :268-279
[2]   Performance characteristics of a Kodak computed radiography system [J].
Bradford, CD ;
Peppler, WW ;
Dobbins, JT .
MEDICAL PHYSICS, 1999, 26 (01) :27-37
[3]   Principles of digital radiography with large-area, electronically readable detectors: A review of the basics [J].
Chotas, HG ;
Dobbins, JT ;
Ravin, CE .
RADIOLOGY, 1999, 210 (03) :595-599
[4]   A SPATIAL-FREQUENCY DEPENDENT QUANTUM ACCOUNTING DIAGRAM AND DETECTIVE QUANTUM EFFICIENCY MODEL OF SIGNAL AND NOISE-PROPAGATION IN CASCADED IMAGING-SYSTEMS [J].
CUNNINGHAM, IA ;
WESTMORE, MS ;
FENSTER, A .
MEDICAL PHYSICS, 1994, 21 (03) :417-427
[5]   DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES [J].
DOBBINS, JT ;
ERGUN, DL ;
RUTZ, L ;
HINSHAW, DA ;
BLUME, H ;
CLARK, DC .
MEDICAL PHYSICS, 1995, 22 (10) :1581-1593
[6]   Measurement of the presampled two-dimensional modulation transfer function of digital imaging systems [J].
Fetterly, KA ;
Hangiandreou, NJ ;
Schueler, BA ;
Ritenour, ER .
MEDICAL PHYSICS, 2002, 29 (05) :913-921
[7]   A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[8]   BASIC IMAGING PROPERTIES OF A COMPUTED RADIOGRAPHIC SYSTEM WITH PHOTOSTIMULABLE PHOSPHORS [J].
FUJITA, H ;
UEDA, K ;
MORISHITA, J ;
FUJIKAWA, T ;
OHTSUKA, A ;
SAI, T .
MEDICAL PHYSICS, 1989, 16 (01) :52-59
[9]   System considerations in CCD-based x-ray imaging for digital chest radiography and digital mammography [J].
Hejazi, S ;
Trauernicht, DP .
MEDICAL PHYSICS, 1997, 24 (02) :287-297
[10]   IMAGING PERFORMANCE OF A DIGITAL STORAGE PHOSPHOR SYSTEM [J].
HILLEN, W ;
SCHIEBEL, U ;
ZAENGEL, T .
MEDICAL PHYSICS, 1987, 14 (05) :744-751