Sequential detection of Salmonella typhimurium and Bacillus anthracis spores using magnetoelastic biosensors

被引:90
作者
Huang, S. [1 ]
Yang, H.
Lakshmanan, R. S.
Johnson, M. L.
Wan, J.
Chen, I. -H. [1 ]
Wikle, H. C., III
Petrenko, V. A. [2 ]
Barbaree, J. M. [1 ]
Chin, B. A.
机构
[1] Auburn Univ, Dept Bot & Microbiol, Auburn, AL 36849 USA
[2] Auburn Univ, Dept Pathobiol, Auburn, AL 36849 USA
关键词
Multiple detection; Magnetoelastic; Biosensor; Phage; Salmonella typhimurium; Bacillus anthracis spores; PHAGE; WIRELESS;
D O I
10.1016/j.bios.2008.09.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Multiple phage-based magnetoelastic (ME) biosensors were simultaneously monitored for the detection of different biological pathogens that were sequentially introduced to the measurement system. The biosensors were formed by immobilizing phage and 1 mg/ml BSA (blocking agent) onto the magnetoelastic resonator's surface. The detection system included a reference sensor as a control, an E2 phage-coated sensor specific to S. typhimurium, and a JRB7 phage-coated sensor specific to B. anthracis spores. The sensors were free standing during the test, being held in place by a magnetic field. Upon sequential exposure to single pathogenic solutions. only the biosensor coated with the corresponding specific phage responded. As the cells/spores were captured by the specific phage-coated sensor. the mass of the sensor increased, resulting in a decrease in the sensor's resonance frequency. Additionally, non-specific binding was effectively eliminated by BSA blocking and was verified by the reference sensor, which showed no frequency shift. Scanning electron microscopy was used to visually verify the interaction of each biosensor with its target analyte. The results demonstrate that multiple magnetoelastic sensors may be simultaneously monitored to detect specifically targeted pathogenic species with good selectivity. This research is the first stage of an ongoing effort to simultaneously detect the presence of multiple pathogens in a complex analyte. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1730 / 1736
页数:7
相关论文
共 17 条
[1]
Wireless magnetoelastic resonance sensors: A critical review [J].
Grimes, CA ;
Mungle, CS ;
Zeng, ZF ;
Jain, MK ;
Dreschel, WR ;
Paulose, M ;
Ong, KG .
SENSORS, 2002, 2 (07) :294-313
[2]
A magnetoelastic resonance biosensor immobilized with polyclonal antibody for the detection of Salmonella typhimurium [J].
Guntupalli, R. ;
Hu, J. ;
Lakshmanan, Ramji S. ;
Huang, T. S. ;
Barbaree, James M. ;
Chin, Bryan A. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1474-1479
[3]
The effect of annealing and gold deposition on the performance of magnetoelastic biosensors [J].
Huang, S. ;
Hu, J. ;
Wan, J. ;
Johnson, M. L. ;
Shu, H. ;
Chin, B. A. .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (03) :380-386
[4]
JOHNSON ML, 2008, SENSOR ACTUAT A-PHYS, P38
[5]
Phage immobilized magnetoelastic sensor for the detection of Salmonella typhimurium [J].
Lakshmanan, Ramji S. ;
Guntupalli, Rajesh ;
Hu, Jing ;
Kim, Dong-Joo ;
Petrenko, Valery A. ;
Barbaree, James M. ;
Chin, Bryan A. .
JOURNAL OF MICROBIOLOGICAL METHODS, 2007, 71 (01) :55-60
[6]
Detection of Salmonella typhimurium in fat free milk using a phage immobilized magnetoelastic sensor [J].
Lakshmanan, Ramji S. ;
Guntupalli, Rajesh ;
Hu, Jing ;
Petrenko, Valery A. ;
Barbaree, James M. ;
Chin, Bryan A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 126 (02) :544-550
[7]
Correction for longitudinal mode vibration in thin slender beams [J].
Liang, Cai ;
Morshed, Shakib ;
Prorok, Barton C. .
APPLIED PHYSICS LETTERS, 2007, 90 (22)
[8]
Phage as a molecular recognition element in biosensors immobilized by physical adsorption [J].
Nanduri, Viswaprakash ;
Sorokulova, Iryna B. ;
Samoylov, Alexandre M. ;
Simonian, Aleksandr L. ;
Petrenko, Valery A. ;
Vodyanoy, Vitaly .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (06) :986-992
[9]
Affinity-selected filamentous bacteriophage as a probe for acoustic wave biodetectors of Salmonella typhimurium [J].
Olsen, EV ;
Sorokulova, IB ;
Petrenko, VA ;
Chen, IH ;
Barbaree, JM ;
Vodyanoy, VJ .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1434-1442
[10]
Quantification of multiple bioagents with wireless, remote-query magnetoelastic microsensors [J].
Ong, Keat G. ;
Zeng, Kefeng ;
Yang, Xiping ;
Shankar, Karthik ;
Ruan, Chuanmin ;
Grimes, Craig A. .
IEEE SENSORS JOURNAL, 2006, 6 (03) :514-523