Predictive modeling of defibrillation using hexahedral and tetrahedral finite element models: recent advances

被引:8
作者
Triedman, John K. [1 ]
Jolley, Matthew [1 ]
Stinstra, Jeroen [2 ]
Brooks, Dana H. [3 ]
MacLeod, Rob [2 ]
机构
[1] Childrens Hosp Boston, Dept Cardiol, Boston, MA USA
[2] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT USA
[3] Northeastern Univ, Dept Elect Engn, Boston, MA 02115 USA
关键词
ICD; Defibrillation; Modeling; Pediatric electrophysiology;
D O I
10.1016/j.jelectrocard.2008.08.002
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Implanted cardioverter/defribillator (ICD) implants may be complicated by body size and anatomy. One approach to this problem has been the adoption of creative, extracardiac implant strategies using standard ICD components. Because data on safety or efficacy of such ad hoc implant strategies are lacking, we have developed image-based finite element models to compare electric fields and expected defibrillation thresholds (DFTs) using standard and novel electrode locations. In this article, we review recently published studies by our group using such models and progress in meshing strategies to improve efficiency and visualization. Our preliminary observations predict that they may be large changes in defibrillation thresholds with clinically relevant variations of electrode placement. Extracardiac ICDs of various lead configurations are predicted to be effective in both children and adults. This approach may aid both ICD development and patient-specific optimization of electrode placement, but the simplified nature of current models dictates further development and validation before clinical or industrial use. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:483 / 486
页数:4
相关论文
共 16 条
[1]
Impact of transvenous lead position on active-can ICD defibrillation: A computer simulation study [J].
Aguel, F ;
Eason, JC ;
Trayanova, NA ;
Siekas, G ;
Fishler, MG .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01) :158-164
[2]
Template-based finite-element mesh generation from medical images [J].
Baghdadi, L ;
Steinman, DA ;
Ladak, HM .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2005, 77 (01) :11-21
[3]
Minimally invasive Cardioverter defibrillator implantation for children: An animal model and pediatric case report [J].
Berul, CI ;
Triedman, JK ;
Forbess, J ;
Bevilacqua, LM ;
Alexander, ME ;
Dahlby, D ;
Gilkerson, JO ;
Walsh, EP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (12) :1789-1794
[4]
Long-term comparison of the implantable cardioverter defibrillator versus amiodarone - Eleven-year follow-up of a subset of patients in the Canadian Implantable Defibrillator Study (CIDS) [J].
Bokhari, F ;
Newman, D ;
Greene, M ;
Korley, V ;
Mangat, I ;
Dorian, P .
CIRCULATION, 2004, 110 (02) :112-116
[5]
A randomized study of the prevention of sudden death in patients with coronary artery disease [J].
Buxton, AE ;
Lee, KL ;
Fisher, JD ;
Josephson, ME ;
Prystowsky, EN ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) :1882-1890
[6]
de Jongh AL, 1999, PACE, V22, P152, DOI 10.1111/j.1540-8159.1999.tb00323.x
[7]
SPECIFIC RESISTANCE OF BIOLOGICAL MATERIAL-A COMPENDUM OF DATA FOR BIOMEDICAL ENGINEER AND PHYSIOLOGIST [J].
GEDDES, LA ;
BAKER, LE .
MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (03) :271-&
[8]
Grace A. A., 2005, HEART RHYTHM, V2, P1036
[9]
A computer modeling tool for comparing novel ICD electrode orientations in children and adults [J].
Jolley, Matthew ;
Stinstra, Jeroen ;
Pieper, Steve ;
MacLeod, Rob ;
Brooks, Dana H. ;
Cecchin, Frank ;
Triedman, John K. .
HEART RHYTHM, 2008, 5 (04) :565-572
[10]
PREDICTING CARDIOTHORACIC VOLTAGES DURING HIGH-ENERGY SHOCKS - METHODOLOGY AND COMPARISON OF EXPERIMENTAL TO FINITE-ELEMENT MODEL DATA [J].
JORGENSON, DB ;
SCHIMPF, PH ;
SHEN, I ;
JOHNSON, G ;
BARDY, GH ;
HAYNOR, DR ;
KIM, YM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (06) :559-571