Solid-phase extraction/MALDI-MS: Extended ion-pairing surfaces for the on-target cleanup of protein samples

被引:37
作者
Zhang, L
Orlando, R
机构
[1] Univ Georgia, Complex Carbohydrate Res Ctr, Dept Biochem & Mol Biol, Athens, GA 30602 USA
[2] Univ Georgia, Dept Chem, Athens, GA 30602 USA
关键词
D O I
10.1021/ac990328e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The surface of a matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) target can be covalently modified so that it behaves like a medium for solid-phase extraction (SPE). These modified targets are capable of binding molecules of interest, but not contaminants, from sample solutions placed on them, This allows the analyte to be cleaned up on the probe surface by simply washing the target to remove the contaminants prior to MALDI-MS analysis. A limitation of the current SPE/MALDI-MS targets is that they have a fairly low binding capacity, since the coating on these targets is based upon self-assembled monolayers (SAMs). To overcome this limitation, we have investigated new surface coatings for SPE/MALDI-MS that will have a higher binding capacity than targets modified with SAMs. Here, we describe the development of new SPE/MALDI-MS surfaces that have very high molecular weight (>300 000) polylysine chains attached to them. Targets modified in this manner are capable of binding peptides/proteins by ion-pairing interactions and have approximately 100 times the binding capacity of the SAM-based targets. Furthermore, these polylysine targets can capture over 60% of a protein from a highly contaminated solution. Consequently, polylysine SPE/MALDI-MS targets offer a practical solution for analyzing very small volumes (<1 mu L) of peptide/protein solutions contaminated with high levels of inorganic salts, buffers, detergents, chaotropic agents, and other solubilizing agents.
引用
收藏
页码:4753 / 4757
页数:5
相关论文
共 13 条
[1]  
BLAKLEDGE JA, 1995, ANAL CHEM, V67, P843
[2]   A desalting approach for MALDI-MS using on-probe hydrophobic self assembled monolayers [J].
Brockman, AH ;
Dodd, BS ;
Orlando, N .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4716-4720
[3]   PROBE IMMOBILIZED AFFINITY-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
BROCKMAN, AH ;
ORLANDO, R .
ANALYTICAL CHEMISTRY, 1995, 67 (24) :4581-4585
[4]  
Brockman AH, 1998, J MASS SPECTROM, V33, P1141, DOI 10.1002/(SICI)1096-9888(1998110)33:11<1141::AID-JMS732>3.3.CO
[5]  
2-L
[6]  
Kallweit U, 1996, RAPID COMMUN MASS SP, V10, P845, DOI 10.1002/(SICI)1097-0231(199605)10:7<845::AID-RCM568>3.0.CO
[7]  
2-R
[8]   MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY OF PROTEINS ELECTROBLOTTED AFTER POLYACRYLAMIDE-GEL ELECTROPHORESIS [J].
STRUPAT, K ;
KARAS, M ;
HILLENKAMP, F ;
ECKERSKORN, C ;
LOTTSPEICH, F .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :464-470
[9]   POLY(VINYLIDENE DIFLUORIDE) MEMBRANES AS THE INTERFACE BETWEEN LASER-DESORPTION MASS-SPECTROMETRY, GEL-ELECTROPHORESIS, AND IN-SITU PROTEOLYSIS [J].
VESTLING, MM ;
FENSELAU, C .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :471-477
[10]   IMPROVED MASS ACCURACY IN MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME-OF-FLIGHT MASS-SPECTROMETRY OF PEPTIDES [J].
VORM, O ;
MANN, M .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :955-958