Lateral Retinacular Release Rates in Mobile- versus Fixed-bearing TKA

被引:24
作者
Yang, Charles C. [2 ]
McFadden, Lee A. [3 ]
Dennis, Douglas A. [1 ,4 ,5 ,6 ]
Kim, Raymond H. [1 ]
Sharma, Adrija [7 ]
机构
[1] Colorado Joint Replacement, Denver, CO 80210 USA
[2] Triangle Orthopaed Associates Pa, Durham, NC 27704 USA
[3] Madigan Army Med Ctr, Orthopaed Surg Serv, Tacoma, WA 98431 USA
[4] Univ Tennessee, Dept Biomed Engn, Knoxville, TN USA
[5] Univ Colorado, Hlth Sci Ctr, Denver, CO USA
[6] Rocky Mt Musculoskeletal Res Lab, Denver, CO USA
[7] Univ Tennessee, Ctr Musculoskeletal Res, Knoxville, TN USA
关键词
D O I
10.1007/s11999-008-0425-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Controversy exists as to whether bearing mobility facilitates centralization of the extensor mechanism after TKA. To assess the incidence of lateral retinacular release, we retrospectively reviewed 1318 consecutive primary TKAs (1032 patients) performed by one surgeon using either a rotating-platform bearing (940) or a fixed bearing (378) from the same implant system. The selection of a fixed- versus mobile-bearing TKA was primarily based on age with patients younger than 70 years receiving a mobile-bearing TKA. We performed a lateral release whenever continuous symmetric patellar facet contact with the trochlear groove from 0 degrees to 90 degrees of flexion was not obtained using the rule of no thumb after tourniquet release. One hundred four of 1318 knees (7.9%) had a lateral release. We performed more lateral releases in the fixed-bearing group (14.3% [54 of 378]) than in the mobile-bearing group (5.3% [50 of 940]). Patellar tilt occurred more often in the mobile-bearing group (10% [94 of 940]) than in the fixed-bearing group (6.9% [26 of 378]), although the magnitude of mean patellar tilt was small in both groups (mobile-bearing 3.0 degrees; fixed bearing 2.55 degrees). No patient had patellar subluxation greater than 5 mm. We suspect the fewer lateral releases in the mobile-bearing group is the result of better extensor mechanism centralization provided by bearing rotation.
引用
收藏
页码:2656 / 2661
页数:6
相关论文
共 33 条
[1]  
Aglietti P, 1988, J Arthroplasty, V3, P17, DOI 10.1016/S0883-5403(88)80049-4
[2]   FEMORAL ROTATIONAL ALIGNMENT, BASED ON THE ANTEROPOSTERIOR AXIS, IN TOTAL KNEE ARTHROPLASTY IN A VALGUS KNEE - A TECHNICAL NOTE [J].
ARIMA, J ;
WHITESIDE, LA ;
MCCARTHY, DS ;
WHITE, SE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09) :1331-1334
[3]  
BERGER RA, 1993, CLIN ORTHOP RELAT R, V286, P40
[4]  
BINDELGLASS DF, 1993, CLIN ORTHOP RELAT R, P103
[5]  
BRICK GW, 1988, CLIN ORTHOP RELAT R, P163
[6]   Long-term followup after mobile-bearing total knee replacement [J].
Buechel, FF .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :40-50
[7]  
BUSCH MT, 1989, CLIN SPORT MED, V8, P279
[8]   Cemented rotating-platform total knee replacement - A concise follow-up, at a minimum of fifteen years, of a previous report [J].
Callaghan, JJ ;
O'Rourke, MR ;
Iossi, MF ;
Liu, SS ;
Goetz, DD ;
Vittetoe, DA ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :1995-1998
[9]   Mobile-bearing knee replacement - Concepts and results [J].
Callaghan, JJ ;
Insall, JN ;
Greenwald, AS ;
Dennis, DA ;
Komistek, RD ;
Murray, DW ;
Bourne, RB ;
Rorabeck, CH ;
Dorr, LD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (07) :1020-1041
[10]  
DENNIS DA, 1992, CLIN ORTHOP RELAT R, P168