Soft tissue composition of pigs measured with dual x-ray absorptiometry: Comparison with chemical analyses and effects of carcass thicknesses

被引:47
作者
Lukaski, HC
Marchello, MJ
Hall, CB
Schafer, DM
Siders, WA
机构
[1] USDA ARS, Grand Forks Human Nutr Res Ctr, Grand Forks, ND 58202 USA
[2] N Dakota State Univ, Dept Anim & Range Sci, Fargo, ND 58105 USA
关键词
fat; fat-free mass; bone-free; carcass thickness;
D O I
10.1016/S0899-9007(99)00154-9
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Evidence of the validity and accuracy of dual x-ray absorptiometry (DXA) to measure in vivo body composition is limited. We compared DXA estimates made in prone and side positions with measurements of chemical composition of 20 pigs (10 barrows and 10 gilts) weighing 52-113 kg. DXA yielded similar estimates of body composition in prone and side positions. DXA estimates of body composition were significantly correlated with reference compositional values (r(2) = 0.927-0.998). No significant differences were found for determinations of body weight, fat mass (FIM), fat free mass (FFM), bone-free, and fat-free mass (BFFFM) between DXA and chemical determinations. DXA significantly underpredicted percent fat (% fat); it underestimated FM (20%, P > 0.05). and overestimated FFM and BFFFM (6 and 9%, respectively, P > 0.05). Differences between individual determinations of FM and % fat by chemical analyses and DXA were significantly correlated with mean values. No significant correlations were found between the differences for weight, FM, % fat, FFM, and BFFFM and measurements of carcass breadth (19-28 cm) and width (15-25 cm). Total errors in determination of DXA body composition variables were similar with body thicknesses less than and greater than 24 cm. These findings indicate that DXA is a valid and accurate method for determination of soft tissue composition. Initial problems with DXA determinations of % fat apparently have been reconciled partially with revisions in soft tissue analytic software. (C) Elsevier Science Inc. 1999.
引用
收藏
页码:697 / 703
页数:7
相关论文
共 24 条
[1]  
[Anonymous], AM J PHYSIOL
[2]  
*ASS OFF AN CHEM, 1990, OFF METH AN
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   VALIDATION AND APPLICATION OF DUAL-ENERGY X-RAY ABSORPTIOMETRY TO MEASURE BONE MASS AND BODY-COMPOSITION IN SMALL INFANTS [J].
BRUNTON, JA ;
BAYLEY, HS ;
ATKINSON, SA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 58 (06) :839-845
[5]   ACCURACY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR BODY-COMPOSITION MEASUREMENTS IN CHILDREN [J].
ELLIS, KJ ;
SHYPAILO, RJ ;
PRATT, JA ;
POND, WG .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 60 (05) :660-665
[6]   4-COMPONENT MODEL FOR THE ASSESSMENT OF BODY-COMPOSITION IN HUMANS - COMPARISON WITH ALTERNATIVE METHODS, AND EVALUATION OF THE DENSITY AND HYDRATION OF FAT-FREE MASS [J].
FULLER, NJ ;
JEBB, SA ;
LASKEY, MA ;
COWARD, WA ;
ELIA, M .
CLINICAL SCIENCE, 1992, 82 (06) :687-693
[7]   APPENDICULAR SKELETAL-MUSCLE MASS - MEASUREMENT BY DUAL-PHOTON ABSORPTIOMETRY [J].
HEYMSFIELD, SB ;
SMITH, R ;
AULET, M ;
BENSEN, B ;
LICHTMAN, S ;
WANG, J ;
PIERSON, RN .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 52 (02) :214-218
[8]   DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENTS OF BODY-COMPOSITION - EFFECTS OF DEPTH AND TISSUE THICKNESS, INCLUDING COMPARISONS WITH DIRECT ANALYSIS [J].
JEBB, SA ;
GOLDBERG, GR ;
JENNINGS, G ;
ELIA, M .
CLINICAL SCIENCE, 1995, 88 (03) :319-324
[9]   Preliminary evidence that DEXA provides an accurate assessment of body composition [J].
Kohrt, WM .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (01) :372-377
[10]   Dual-energy X-ray absorptiometry and body composition [J].
Laskey, MA .
NUTRITION, 1996, 12 (01) :45-51