Performance of a miniature magnetic position sensor for three-dimensional ultrasound imaging

被引:83
作者
Leotta, DF
Detmer, PR
Martin, RW
机构
[1] UNIV WASHINGTON,DEPT SURG,SEATTLE,WA 98195
[2] UNIV WASHINGTON,DEPT ANESTHESIOL,SEATTLE,WA 98195
关键词
ultrasound; imaging; three-dimensional; magnetometer; position; orientation;
D O I
10.1016/S0301-5629(97)00043-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A miniature magnetic position sensor used for three-dimensional ultrasound imaging was tested for precision and accuracy in vitro. The sensor alone was able to locate points with root-mean-square (rms) uncertainty of 1.7 mm and accuracy of 0.05 +/- 0.62 mm over its specified operating range of 50 cm, With an ultrasound imaging system, a point was located from arbitrary viewing windows with 2.4-mm rms uncertainty and 0.06 +/- 0.68 mm accuracy, If viewing windows were Limited to those representative of a typical ultrasound examination, the system could achieve rms uncertainty in point location of < I mm, Performance was not affected by operation of the imaging system when the sensor was mounted on an ultrasound scanhead. Sensitivity to metals in the operating environment was also measured, (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:597 / 609
页数:13
相关论文
共 20 条
[11]  
LEOTTA DF, 1995, P IEEE INT ULTR S SE, P1415
[12]  
MARTIN R, 1993, COMPUT CARDIOL, P25
[13]   VENTRICULAR VOLUME MEASUREMENT FROM A MULTIPLANAR TRANSESOPHAGEAL ULTRASONIC-IMAGING SYSTEM - AN INVITRO STUDY [J].
MARTIN, RW ;
BASHEIN, G ;
DETMER, PR ;
MORITZ, WE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (05) :442-449
[14]  
PRETORIUS DH, 1994, J ULTRAS MED, V13, P871
[15]  
RICCABONA M, 1995, J ULTRAS MED, V14, P881
[16]  
Roelandt J R, 1994, J Am Soc Echocardiogr, V7, P217
[17]   3-DIMENSIONAL ECHOCARDIOGRAPHIC MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN-VITRO - COMPARISON WITH 2-DIMENSIONAL ECHOCARDIOGRAPHY AND CINEVENTRICULOGRAPHY [J].
SAPIN, PM ;
SCHROEDER, KD ;
SMITH, MD ;
DEMARIA, AN ;
KING, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1530-1537
[18]   COMPARISON OF 2-DIMENSIONAL AND 3-DIMENSIONAL ECHOCARDIOGRAPHY WITH CINEVENTRICULOGRAPHY FOR MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN PATIENTS [J].
SAPIN, PM ;
SCHRODER, KM ;
GOPAL, AS ;
SMITH, MD ;
DEMARIA, AN ;
KING, DL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) :1054-1063
[19]   A 3-DIMENSIONAL MODEL OF TONGUE MOVEMENT BASED ON ULTRASOUND AND X-RAY MICROBEAM DATA [J].
STONE, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (05) :2207-2217
[20]   FRAMELESS STEREOTAXIC ULTRASONOGRAPHY - METHOD AND APPLICATIONS [J].
TROBAUGH, JW ;
RICHARD, WD ;
SMITH, KR ;
BUCHOLZ, RD .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1994, 18 (04) :235-246