Spatially resolved detection of attomole quantities of organic molecules localized in picoliter vials using time-of-flight secondary ion mass spectrometry

被引:29
作者
Braun, RM [1 ]
Beyder, A [1 ]
Xu, JY [1 ]
Wood, MC [1 ]
Ewing, AG [1 ]
Winograd, N [1 ]
机构
[1] Penn State Univ, Dept Chem, Davey Lab 152, University Pk, PA 16802 USA
关键词
D O I
10.1021/ac9902042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has been utilized to detect femtomole and ateomole quantities of organic species from within silicon nanovials, By using high-density arrays (10 000 nanovials/cm(2)) it is possible to chemically characterize diverse sample sets within a single chemical image. Molecular sensitivities, for the compounds investigated, vary between 85 attomoles and 25 femtomoles, and typical acquisition times are approximately 100 ms per nanovial. These vials are fabricated using photolithography and KOH etching of Si{001} wafers to create wells, with a pyramidal cross section, ranging in size from 25 to 5625 mu cm(2). The volume ranges from 30 femtoliters to 100 picoliters, respectively. A drawn glass microinjector and solenoid-driven dispenser are utilized to array picoliter volumes of organic compounds into individual silicon nanovials. Solution concentrations typically range from 1 x 10(-2) to 1 x 10(-4) M allowing femtomole and even attomole quantities of material to be dispensed into each vial.
引用
收藏
页码:3318 / 3324
页数:7
相关论文
共 26 条
  • [11] HIETPAS PB, 1996, NANOFABRICATION BIOS, P139
  • [12] MICROVIALS ON A SILICON-WAFER FOR SAMPLE INTRODUCTION IN CAPILLARY ELECTROPHORESIS
    JANSSON, M
    EMMER, A
    ROERAADE, J
    LINDBERG, U
    HOK, B
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 626 (02): : 310 - 314
  • [13] JESPERSEN S, 1996, MASS SPECTROMETRY BI, P217
  • [14] LITBORN E, 1998, HPCE ABSTR, P205
  • [15] MALDI on a chip: Analysis of arrays of low femtomole to subfemtomole quantities of synthetic oligonucleotides and DNA diagnostic products dispensed by a piezoelectric pipet
    Little, DP
    Cornish, TJ
    ODonnell, MJ
    Braun, A
    Cotter, RJ
    Koster, H
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (22) : 4540 - 4546
  • [16] Fabrication of plastic microfluid channels by imprinting methods
    Martynova, L
    Locascio, LE
    Gaitan, M
    Kramer, GW
    Christensen, RG
    MacCrehan, WA
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (23) : 4783 - 4789
  • [17] Randomly ordered addressable high-density optical sensor arrays
    Michael, KL
    Taylor, LC
    Schultz, SL
    Walt, DR
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (07) : 1242 - 1248
  • [18] UV laser machined polymer substrates for the development of microdiagnostic systems
    Roberts, MA
    Rossier, JS
    Bercier, P
    Girault, H
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (11) : 2035 - 2042
  • [19] Synthesis and applications of small molecule libraries
    Thompson, LA
    Ellman, JA
    [J]. CHEMICAL REVIEWS, 1996, 96 (01) : 555 - 600
  • [20] Willey KF, 1998, RAPID COMMUN MASS SP, V12, P1253, DOI 10.1002/(SICI)1097-0231(19980930)12:18<1253::AID-RCM317>3.0.CO