A small, fluorescent fiber-optic potassium sensor is described with a working range which covers both intracellular cytosolic and blood levels of potassium at the respective physiological pH values. The highly potassium-selective ionophore, BME-44, is retained in a plasticized poly(vinyl chloride) (PVC) Nm which is placed on the end of an optical fiber. Three optode configurations are given, employing different lipophilic, fluorescent pH chromoionophores (Nile Blue derivatives), demonstrating the ability to improve the detection limit and tune the dynamic range to the desired region of interest. These optodes also have excellent selectivity over sodium, calcium and magnesium Use of fluorescence (in contrast to absorbance) provides a means to reduce the sensor size dramatically while retaining the same signal-to-noise ratio. These optodes measure the sample's potassium activity (rather than concentration) provided that the sample's pH is measured simultaneously by another sensor, such as a glass pH electrode.
引用
收藏
页码:8 / 12
页数:5
相关论文
共 26 条
  • [1] A COMPARATIVE-STUDY OF 2 DIFFERENT APPROACHES FOR ACTIVE OPTICAL SENSING OF POTASSIUM WITH A CHROMOIONOPHORE
    ALAVAMORENO, F
    PEREIROGARCIA, R
    DIAZGARCIA, ME
    SANZMEDEL, A
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) : 413 - 419
  • [2] Ammann, 1986, ION SELECTIVE MICROE
  • [3] SELECTIVITY OF ION-SENSITIVE BULK OPTODES
    BAKKER, E
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1805 - 1812
  • [4] SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES
    BAKKER, E
    LERCHI, M
    ROSATZIN, T
    RUSTERHOLZ, B
    SIMON, W
    [J]. ANALYTICA CHIMICA ACTA, 1993, 278 (02) : 211 - 225
  • [5] DETERMINATION OF COMPLEX-FORMATION CONSTANTS OF NEUTRAL CATION-SELECTIVE IONOPHORES IN SOLVENT POLYMERIC MEMBRANES
    BAKKER, E
    WILLER, M
    LERCHI, M
    SEILER, K
    PRETSCH, E
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (04) : 516 - 521
  • [6] DETECTION LIMIT OF ION-SELECTIVE BULK OPTODES AND CORRESPONDING ELECTRODES
    BAKKER, E
    WILLER, M
    PRETSCH, E
    [J]. ANALYTICA CHIMICA ACTA, 1993, 282 (02) : 265 - 271
  • [7] NEW MICRO-ELECTRODE TECHNIQUES FOR INTRACELLULAR WORK IN SMALL CELLS
    BROWN, KT
    FLAMING, DG
    [J]. NEUROSCIENCE, 1977, 2 (06) : 813 - 827
  • [8] LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS
    DINTEN, O
    SPICHIGER, UE
    CHANIOTAKIS, N
    GEHRIG, P
    RUSTERHOLZ, B
    MORF, WE
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (06) : 596 - 603
  • [9] SERUM ANALYSIS FOR POTASSIUM-IONS USING A FIBER OPTIC SENSOR
    GARCIA, RP
    MORENO, FA
    GARCIA, MED
    SANZMEDEL, A
    NARAYANASWAMY, R
    [J]. CLINICA CHIMICA ACTA, 1992, 207 (1-2) : 31 - 40
  • [10] NOVEL TYPE OF ION-SELECTIVE FLUOROSENSOR BASED ON THE INNER FILTER EFFECT - AN OPTRODE FOR POTASSIUM
    HE, HR
    LI, H
    MOHR, G
    KOVACS, B
    WERNER, T
    WOLFBEIS, OS
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (02) : 123 - 127