In-situ calibration of the implantable force transducer

被引:18
作者
Herzog, W
Hasler, EM
Leonard, TR
机构
[1] Faculty of Kinesiology, University of Calgary, Calgary, Alta. T2N 1N4, Canada
关键词
muscle force measurements; patellar tendon; cat; inverse dynamics; experimental calibration;
D O I
10.1016/0021-9290(96)00073-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Recently, an implantable force transducer (IFT) has been introduced [Xu et al. (1992, J. Biomech. Engng 114, 170-177)] which can be used in tight spaces where force recordings with established transducers, such as the buckle-type transducers, are not possible because of impingement artifacts. The IFT is easily implanted in chronic animal preparations; however, calibration of the IFT in terminal experiments has produced unreliable results. The problems of IFT calibration are that minute movements of the transducer within the tendon, slight misalignments of the tendon, or slight errors in the line of pull cause dramatic changes in the IFT voltage output for a given applied calibration load. Here, we propose a method that eliminates the above calibration problems primarily because the target tendon is left in situ, the calibration loads are applied by the muscles which insert into the target tendon, and the transducer is implanted into the target tendon about two weeks prior to calibration. The theoretical and experimental approaches are demonstrated for the cat patellar tendon, but in principle can be performed with any tendon. The results are repeatable, lie within expected values, and reproduce some of the basic properties which have been observed in prior IFT testing. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:1649 / 1652
页数:4
相关论文
共 10 条
[1]   IN-VITRO EVALUATION OF AN IMPLANTABLE FORCE TRANSDUCER (IFT) IN A PATELLAR TENDON MODEL [J].
GLOS, DL ;
BUTLER, DL ;
GROOD, ES ;
LEVY, MS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :335-343
[2]   CAT STEP CYCLE - HIND LIMB JOINT ANGLES AND MUSCLE LENGTHS DURING UNRESTRAINED LOCOMOTION [J].
GOSLOW, GE ;
REINKING, RM ;
STUART, DG .
JOURNAL OF MORPHOLOGY, 1973, 141 (01) :1-41
[3]   MECHANICAL OUTPUT OF THE CAT SOLEUS DURING TREADMILL LOCOMOTION - INVIVO VS INSITU CHARACTERISTICS [J].
GREGOR, RJ ;
ROY, RR ;
WHITING, WC ;
LOVELY, RG ;
HODGSON, JA ;
EDGERTON, VR .
JOURNAL OF BIOMECHANICS, 1988, 21 (09) :721-732
[4]  
Grieve D., 1978, Biomechanics, V58, P405
[5]   Evaluation of the implantable force transducer for chronic tendon-force recordings [J].
Herzog, W ;
Archambault, JM ;
Leonard, TR ;
Nguyen, HK .
JOURNAL OF BIOMECHANICS, 1996, 29 (01) :103-109
[6]   A SYSTEM FOR STUDYING THE MECHANICAL-PROPERTIES OF MUSCLES AND THE SENSORIMOTOR CONTROL OF MUSCLE FORCES DURING UNRESTRAINED LOCOMOTION IN THE CAT [J].
HERZOG, W ;
LEONARD, TR ;
STANO, A .
JOURNAL OF BIOMECHANICS, 1995, 28 (02) :211-218
[7]   VALIDATION OF OPTIMIZATION MODELS THAT ESTIMATE THE FORCES EXERTED BY SYNERGISTIC MUSCLES [J].
HERZOG, W ;
LEONARD, TR .
JOURNAL OF BIOMECHANICS, 1991, 24 :31-39
[8]   KNEE MUSCLE MOMENT ARMS FROM MRI AND FROM TENDON TRAVEL [J].
SPOOR, CW ;
VANLEEUWEN, JL .
JOURNAL OF BIOMECHANICS, 1992, 25 (02) :201-206
[9]   FORCES PRODUCED BY MEDIAL GASTROCNEMIUS AND SOLEUS MUSCLES DURING LOCOMOTION IN FREELY MOVING CATS [J].
WALMSLEY, B ;
HODGSON, JA ;
BURKE, RE .
JOURNAL OF NEUROPHYSIOLOGY, 1978, 41 (05) :1203-1216
[10]   THEORETICAL-ANALYSIS OF AN IMPLANTABLE FORCE TRANSDUCER FOR TENDON AND LIGAMENT STRUCTURES [J].
XU, WS ;
BUTLER, DL ;
STOUFFER, DC ;
GROOD, ES ;
GLOS, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (02) :170-177