Graphene oxide based fluorescent aptasensor for adenosine deaminase detection using adenosine as the substrate

被引:63
作者
Xing, Xiao-Jing
Liu, Xue-Guo
Yue-He
Luo, Qing-Ying
Tang, Hong-Wu [1 ]
Pang, Dai-Wen
机构
[1] Wuhan Univ, Wuhan Inst Biotechnol, Res Ctr Nanobiol & Nanomed MOE Innovat Platform 9, Key Lab Analyt Chem Biol & Med,Minist Educ,Coll C, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Graphene oxide; Aptamer; Adenosine; Adenosine deaminase; Inhibition; RESONANCE ENERGY-TRANSFER; SENSING BIOMOLECULES; DNA APTAMER; IN-VITRO; SELECTION; ACID; PLATFORM; LIGANDS; INHIBITION; BIOSENSORS;
D O I
10.1016/j.bios.2012.04.037
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We present a novel fluorescent aptasensor for simple and accurate detection of adenosine deaminase (ADA) activity and inhibition on the basis of graphene oxide (GO) using adenosine (AD) as the substrate. This aptasensor consists of a dye-labeled single-stranded AD specific aptamer, GO and AD. The fluorescence intensity of the dye-labeled AD specific aptamer is quenched very efficiently by GO as a result of strong pi-pi stacking interaction and excellent electronic transference of GO. In the presence of AD, the fluorescence of the GO-based probe is recovered since the competitive binding of AD and GO with the dye-labeled aptamer prevents the adsorption of dye-labeled aptamer on GO. When ADA was introduced to this GO-based probe solution, the fluorescence of the probe was quenched owing to ADA cm convert AD into inosine which has no affinity to the dye-labeled aptamer, thus allowing quantitative investigation of ADA activity. The as-proposed sensor is highly selective and sensitive for the assay of ADA activity with a detection limit of 0.0129 U/mL in clean buffer, which is more than one order of magnitude lower than the previous reports. Meanwhile, a good linear relationship with the correlation coefficient of R=0.9922 was obtained by testing 5% human serum containing a series of concentrations of ADA. Additionally, the inhibition effect of erythro-9-(2-hydroxy-3-nonyl) adenine on ADA activity was investigated in this design. The GO-based fluorescence aptasensor not only provides a simple, cost-effective and sensitive platform for the detection of ADA and its inhibitor but also shows great potential in the diagnosis of ADA-relevant diseases and drug development. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 51 条
[11]   The rise of graphene [J].
Geim, A. K. ;
Novoselov, K. S. .
NATURE MATERIALS, 2007, 6 (03) :183-191
[12]   Graphene: Status and Prospects [J].
Geim, A. K. .
SCIENCE, 2009, 324 (5934) :1530-1534
[13]   Aptamers as ligands in affinity probe capillary electrophoresis [J].
German, I ;
Buchanan, DD ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 1998, 70 (21) :4540-4545
[14]  
GIEREK T, 1987, Auris Nasus Larynx, V14, P97
[15]  
Gocmen E, 2009, BRATISL MED J, V110, P416
[16]   Magnetically assisted fluorescence ratiometric assays for adenosine deaminase using water-soluble conjugated polymers [J].
He Fang ;
Yu MingHui ;
Wang Shu .
CHINESE SCIENCE BULLETIN, 2009, 54 (08) :1340-1344
[17]   A Graphene Nanoprobe for Rapid, Sensitive, and Multicolor Fluorescent DNA Analysis [J].
He, Shijiang ;
Song, Bo ;
Li, Di ;
Zhu, Changfeng ;
Qi, Wenpeng ;
Wen, Yanqin ;
Wang, Lihua ;
Song, Shiping ;
Fang, Haiping ;
Fan, Chunhai .
ADVANCED FUNCTIONAL MATERIALS, 2010, 20 (03) :453-459
[18]  
Hofbrand A.V., 1981, J CLIN PATHOL, V34, P254
[19]   Flow Cytometry-Assisted Detection of Adenosine in Serum with an Immobilized Aptamer Sensor [J].
Huang, Po-Jung Jimmy ;
Liu, Juewen .
ANALYTICAL CHEMISTRY, 2010, 82 (10) :4020-4026
[20]   A DNA APTAMER THAT BINDS ADENOSINE AND ATP [J].
HUIZENGA, DE ;
SZOSTAK, JW .
BIOCHEMISTRY, 1995, 34 (02) :656-665