Transthoracic echocardiography using second harmonic imaging -: Diagnostic alternative to transesophageal echocardiography for the detection of atrial right to left shunt in patients with cerebral embolic events

被引:87
作者
Kühl, HP
Hoffmann, R
Merx, MW
Franke, A
Klötzsch, C
Lepper, W
Reineke, T
Noth, J
Hanrath, P
机构
[1] Univ Hosp, Inst Biometry, Aachen, Germany
[2] Univ Hosp, Med Clin 1, Aachen, Germany
[3] Univ Hosp, Dept Neurol, Aachen, Germany
关键词
D O I
10.1016/S0735-1097(99)00412-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to evaluate whether transthoracic contrast echocardiography using second harmonic imaging (SHI) is a diagnostic alternative to transesophageal contrast echocardiography (TEE) for the detection of atrial right to left shunt. BACKGROUND Paradoxic embolism is considered to be the major cause of cerebral ischemic events in young patients. Contrast echocardiography using TEE has proven to be superior to transthoracic echocardiography (TTE) for the detection of atrial shunting; SHI is a new imaging modality that enhances the visualization of echocardiographic contrast agents. METHODS We evaluated 111 patients with an ischemic cerebral embolic event for the presence of atrial right to left shunt using an intravenous (IV) contrast agent in combination with three different echocardiographic imaging modalities: 1) TTE using fundamental imaging (FI); 2) TTE using SHI; and 3) TEE. The severity of atrial shunting and the duration of contrast visibility within the left heart chambers were evaluated for each imaging modality. Image quality was assessed separately for each modality by semiquantitative scoring (0 poor to 3 excellent). Presence of atrial right to left shunt was defined as detection of contrast bubbles in the left atrium within the first three cardiac cycles after contrast appearance in the right atrium either spontaneously or after the Valsalva maneuver. RESULTS A total of 57 patients showed evidence of atrial right to left shunt with either imaging modality. Fifty-one studies were positive with TEE, 52 studies were positive with SHI, and 32 were positive with FI (p < 0.001 for FI vs. SHI and TEE). The severity of contrast passage was significantly larger using SHI (61.6 +/- 80.2 bubbles) compared to Fl (53.7 +/- 69.6 bubbles; p < 0.005 vs. SHI) but was not different compared to TEE (43.9 +/- 54.3 bubbles; p = NS vs. SHI). The duration of contrast visibility was significantly longer for SHI (17.4 +/- 12.4 s) compared to FI (13.1 +/- 9.7 s; p < 0.001) and TEE (11.9 +/- 9.6 s; p < 0.02). Mean image quality improved significantly from FI (1.5 +/- 0.8) to SHI (2.0 +/- 0.8; p < 0.001 vs. FI) and TEE (2.5 +/- 0.7; p < 0.001 vs. SHI). CONCLUSIONS In combination with IV contrast injections, TEE and SHI have a comparable yield for the detection of atrial right to left shunt. Both modalities may miss patients with atrial shunting. In young patients with an unexplained cerebrovascular event and no clinical evidence of cardiac disease, a positive SHI study may obviate the need to perform a TEE study to search for cardiac sources of emboli. (C) 1999 by the American College of Cardiology.
引用
收藏
页码:1823 / 1830
页数:8
相关论文
共 44 条
[1]   ATHEROSCLEROTIC DISEASE OF THE AORTIC-ARCH AND THE RISK OF ISCHEMIC STROKE [J].
AMARENCO, P ;
COHEN, A ;
TZOURIO, C ;
BERTRAND, B ;
HOMMEL, M ;
BESSON, G ;
CHAUVEL, C ;
TOUBOUL, PJ ;
BOUSSER, MG .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (22) :1474-1479
[2]   Measurements of harmonic generation in a focused finite-amplitude sound beam [J].
Averkiou, MA ;
Hamilton, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 98 (06) :3439-3442
[3]   Stroke recurrence in patients with patent foramen ovale: The Lausanne Study [J].
Bogousslavsky, J ;
Garazi, S ;
Jeanrenaud, X ;
Aebischer, N ;
VanMelle, G .
NEUROLOGY, 1996, 46 (05) :1301-1305
[4]   TRANSCATHETER CLOSURE OF PATENT FORAMEN OVALE AFTER PRESUMED PARADOXICAL EMBOLISM [J].
BRIDGES, ND ;
HELLENBRAND, W ;
LATSON, L ;
FILIANO, J ;
NEWBURGER, JW ;
LOCK, JE .
CIRCULATION, 1992, 86 (06) :1902-1908
[5]   New concept in echocardiography:: harmonic imaging of tissue without use of contrast agent [J].
Caidahl, K ;
Kazzam, E ;
Lidberg, J ;
Andersen, GN ;
Nordanstig, J ;
Dahlwvist, SR ;
Waldenström, A ;
Wikh, R .
LANCET, 1998, 352 (9136) :1264-1270
[6]   A high-frequency pulsed-wave doppler ultrasound system for the detection and imaging of blood flow in the microcirculation [J].
Christopher, DA ;
Burns, PN ;
Starkoski, BG ;
Foster, FS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (07) :997-1015
[7]   FAILURE OF PREOPERATIVE ECHO TESTING TO PREVENT PARADOXICAL AIR-EMBOLISM - REPORT OF 2 CASES [J].
CUCCHIARA, RF ;
NISHIMURA, RA ;
BLACK, S .
ANESTHESIOLOGY, 1989, 71 (04) :604-607
[8]   TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THE DETECTION OF POTENTIAL CARDIAC SOURCE OF EMBOLISM IN STROKE PATIENTS [J].
CUJEC, B ;
POLASEK, P ;
VOLL, C ;
SHUAIB, A .
STROKE, 1991, 22 (06) :727-733
[9]   TRANSESOPHAGEAL CONTRAST ECHOCARDIOGRAPHY AND COLOR FLOW MAPPING - METHODS OF CHOICE FOR THE DETECTION OF SHUNTS AT THE ATRIAL LEVEL [J].
DEBELDER, MA ;
TOURIKIS, L ;
GRIFFITH, M ;
LEECH, G ;
CAMM, AJ .
AMERICAN HEART JOURNAL, 1992, 124 (06) :1545-1550
[10]   RISK OF PATENT FORAMEN OVALE FOR THROMBOEMBOLIC EVENTS IN ALL AGE-GROUPS [J].
DEBELDER, MA ;
TOURIKIS, L ;
LEECH, G ;
CAMM, AJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (16) :1316-1320