Multiple regions-of-interest analysis of setup uncertainties for head-and-neck cancer radiotherapy

被引:157
作者
Zhang, LF
Garden, AS
Lo, J
Ang, KK
Ahamad, A
Morrison, WH
Rosenthal, DI
Chambers, MS
Zhu, XR
Mohan, R
Dong, L
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Unit 94, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[3] Univ Texas, Dept Biomed Engn, Austin, TX 78712 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 64卷 / 05期
关键词
setup uncertainties; immobilization; in-room volumetric imaging; setup corrections; head-and-neck cancers;
D O I
10.1016/j.ijrobp.2005.12.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To analyze three-dimensional setup uncertainties for multiple regions of interest (ROIs) in head-and-neck region. Methods and Materials: In-room computed tomography (CT) scans were acquired using a CT-on-rails system for 14 patients. Three separate bony ROIs were defined: C2 and C6 vertebral bodies and the palatine process of the maxilla. Translational shifts of 3 ROIs were calculated relative to the marked isocenter on the immobilization mask. Results: The shifts for all 3 ROIs were highly correlated. However, noticeable differences on the order of 2-6 turn existed between any 2 ROIs, indicating the flexibility and/or rotational effect in the head-and-neck region. The palatine process of the maxilla had the smallest right-left shifts because of the tight lateral fit in the face mask, but the largest superior-inferior movement because of in-plane rotation and variations in jaw positions. The neck region (C6) had the largest right-left shifts. The positioning mouthpiece was found effective in reducing variations in the superior-inferior direction. There was no statistically significant improvement for using the S-board (8 out of 14 patients) vs. the short face mask. Conclusions: We found variability in setup corrections for different regions of head-and-neck anatomy. These relative positional variations should be considered when making setup corrections or designing treatment margins. (c) 2006 Elsevier Inc.
引用
收藏
页码:1559 / 1569
页数:11
相关论文
共 28 条
[1]   Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system [J].
Barker, JL ;
Garden, AS ;
Ang, KK ;
O'Daniel, JC ;
Wang, H ;
Court, LE ;
Morrison, WH ;
Rosenthal, DI ;
Chao, KSC ;
Tucker, SL ;
Mohan, R ;
Dong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04) :960-970
[2]   A computerized remote table control for fast on-line patient repositioning: Implementation and clinical feasibility [J].
Bel, A ;
Petrascu, O ;
Van de Vondel, I ;
Coppens, L ;
Linthout, N ;
Verellen, D ;
Storme, G .
MEDICAL PHYSICS, 2000, 27 (02) :354-358
[3]   SETUP DEVIATIONS IN WEDGED PAIR IRRADIATION OF PAROTID-GLAND AND TONSILLAR TUMORS, MEASURED WITH AN ELECTRONIC PORTAL IMAGING DEVICE [J].
BEL, A ;
KEUS, R ;
VIJLBRIEF, RE ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (02) :153-159
[4]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[5]  
Brock Kristy K, 2002, J Appl Clin Med Phys, V3, P241, DOI 10.1120/1.1474229
[6]   Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system [J].
Court, L ;
Rosen, I ;
Mohan, R ;
Dong, L .
MEDICAL PHYSICS, 2003, 30 (06) :1198-1210
[7]   Automatic registration of the prostate for computed-tomography-guided radiotherapy [J].
Court, LE ;
Dong, L .
MEDICAL PHYSICS, 2003, 30 (10) :2750-2757
[8]   Electronic portal image assisted reduction of systematic set-up errors in head and neck irradiation [J].
de Boer, HCJ ;
de Koste, JRV ;
Creutzberg, CL ;
Visser, AG ;
Levendag, PC ;
Heijmen, BJM .
RADIOTHERAPY AND ONCOLOGY, 2001, 61 (03) :299-308
[9]  
Gregoire Vincent, 2003, Rays, V28, P217
[10]   A comparison of field-only electronic portal imaging hard copies with double exposure port films in radiation therapy treatment setup confirmation to determine its clinical application in a radiotherapy center [J].
Hatherly, K ;
Smylie, J ;
Rodger, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03) :791-796