A computerized remote table control for fast on-line patient repositioning: Implementation and clinical feasibility

被引:35
作者
Bel, A [1 ]
Petrascu, O [1 ]
Van de Vondel, I [1 ]
Coppens, L [1 ]
Linthout, N [1 ]
Verellen, D [1 ]
Storme, G [1 ]
机构
[1] Free Univ Brussels, Akad Ziekenhuis, Dept Radiotherapy, B-1090 Brussels, Belgium
关键词
computer; remote couch control; portal imaging; on-line setup corrections;
D O I
10.1118/1.598838
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A computerized remote control for a Siemens ZXT treatment couch was implemented and its characteristics were investigated to establish its feasibility for on-line setup corrections, using portal imagine. Communication with the table was obtained by connecting it via a serial line to a work station. The treatment couch enables "goto" commands in the three main directions and around the isocenter. The accuracy of the movements after giving such a command was checked and the time for each movement was recorded. First, the movements into a single direction were studied (range of -4 to +4 cm and -4 degrees to +-4 degrees). Each command was repeated four times. Second, the table was moved into the three main directions simultaneously. For this experiment a clinically relevant three-dimensional (3-D) normal distribution of shifts was used [N=200, standard deviation (SD) 5 mm in the three main directions]. This latter experiment was done twice: without and with rotations (a distribution with SD 1 degrees). During the first experiment, with shifts into one direction, no systematic deviations were found. The overall accuracy of the shifts was 0.6 mm (1 SD) in each direction and 0.04 degrees (1 SD) for the rotations. The time required for a translation ranged between 4 and 13 s and for the rotation between 8 and 20 s. The second experiment with the 3-D distribution of setup errors yielded an error in the 3-D vector length equal to 0.96 mm (1 SD), independent of rotations. Shifts were performed in less than 11 s for 95% of the cases without rotations. When rotations were also performed, 95% of the movements finished in less than 16 s. In conclusion, the table movements are accurate and enable on-line setup corrections in daily clinical practice. (C) 2000 American Association of Physicists in Medicine. [S0094-2405 (00)00502-2].
引用
收藏
页码:354 / 358
页数:5
相关论文
共 20 条
[1]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[2]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[3]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[4]   ROUTINE CLINICAL ONLINE PORTAL IMAGING FOLLOWED BY IMMEDIATE FIELD ADJUSTMENT USING A TELE-CONTROLLED PATIENT COUCH [J].
DENEVE, W ;
VANDENHEUVEL, F ;
DEBEUKELEER, M ;
COGHE, M ;
THON, L ;
DEROOVER, P ;
VANLANCKER, M ;
STORME, G .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (01) :45-54
[5]   INTERACTIVE USE OF ONLINE PORTAL IMAGING IN PELVIC RADIATION [J].
DENEVE, W ;
VANDENHEUVEL, F ;
COGHE, M ;
VERELLEN, D ;
DEBEUKELEER, M ;
ROELSTRAETE, A ;
DEROOVER, P ;
THON, L ;
STORME, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03) :517-524
[6]   TIME TREND OF PATIENT SETUP DEVIATIONS DURING PELVIC IRRADIATION USING ELECTRONIC PORTAL IMAGING [J].
ELGAYED, AAH ;
BEL, A ;
VIJLBRIEF, R ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 26 (02) :162-171
[7]   THE IMPLEMENTATION OF PATIENT POSITION CORRECTION USING A MEGAVOLTAGE IMAGING DEVICE ON A LINEAR-ACCELERATOR [J].
EVANS, PM ;
GILDERSLEVE, JQ ;
RAWLINGS, C ;
SWINDELL, W .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (789) :833-838
[8]   Interactive three dimensional inspection of patient setup in radiation therapy using digital portal images and computed tomography data [J].
Gilhuijs, KGA ;
Drukker, K ;
Touw, A ;
vandeVen, PJH ;
vanHerk, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (04) :873-885
[9]   Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data [J].
Gilhuijs, KGA ;
vandeVen, PJH ;
vanHerk, M .
MEDICAL PHYSICS, 1996, 23 (03) :389-399
[10]   A tilt and roll device for automated correction of rotational setup errors [J].
Hornick, DC ;
Litzenberg, DW ;
Lam, KL ;
Balter, JM ;
Hetrick, J ;
Ten Haken, RK .
MEDICAL PHYSICS, 1998, 25 (09) :1739-1740