Spectropotentiometry: A new method for in situ imaging of concentration profiles in ion-selective membranes with simultaneous recording of potential-time transients

被引:66
作者
Schneider, B
Zwickl, T
Federer, B
Pretsch, E
Lindner, E
机构
[1] ETH ZURICH,DEPT ORGAN CHEM,CH-8092 ZURICH,SWITZERLAND
[2] TECH UNIV BUDAPEST,INST GEN & ANALYT CHEM,H-1111 BUDAPEST,HUNGARY
关键词
D O I
10.1021/ac9604245
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new spectropotentiometric imaging technique is introduced for studying transport processes in connection with cation interference in H+-selective liquid polymer membranes that contain an indicator dye as chromoionophore, Mounted in a specially designed cell under a microscope, the inner and outer rims of a membrane ring are contacted with electrolyte solutions of identical composition. After the system reaches equilibrium, the pH of the inner solution is raised to a value at which cation interference does occur. Pictures are taken with a nominal resolution of 2.25 mu m in selected wavelength ranges using a CCD imaging camera, and potential-time transients are recorded simultaneously. Concentration profiles of the protonated and unprotonated forms of the chromoionophore are calculated from the pictures and plotted as a function of time. On the basis of these results, the rate-determining process is evaluated, and the possible sources of the nonmonotonic potential-time transients are discussed. The diffusion coefficients of the protonated and unprotonated indicator are obtained by fitting the appropriate diffusion equations to the concentration profiles. The new technique allows a more profound comparison of membrane compositions in order to optimize them systematically.
引用
收藏
页码:4342 / 4350
页数:9
相关论文
共 46 条
[21]   A NOVEL SPECTROSCOPIC METHOD TO IMAGE H2O DISTRIBUTION IN ION-SELECTIVE MEMBRANES [J].
LI, XZ ;
PETROVIC, S ;
HARRISON, DJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :275-280
[22]   MEASUREMENT OF CONCENTRATION PROFILES INSIDE A NITRITE ION-SELECTIVE ELECTRODE MEMBRANE [J].
LI, XZ ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2168-2174
[23]   Dual-sorption model of water uptake in poly(vinyl chloride)-based ion-selective membranes: Experimental water concentration and transport parameters [J].
Li, Z ;
Li, XZ ;
Petrovic, S ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1996, 68 (10) :1717-1725
[24]  
LI Z, 1993, ANAL METHOD INSTRUM, V1, P30
[25]   SWITCHED WALL JET FOR DYNAMIC-RESPONSE MEASUREMENTS [J].
LINDNER, E ;
TOTH, K ;
PUNGOR, E ;
BERUBE, TR ;
BUCK, RP .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :2213-2216
[26]   RESPONSES OF H+ SELECTIVE SOLVENT POLYMERIC MEMBRANE ELECTRODES FABRICATED FROM MODIFIED PVC MEMBRANES [J].
LINDNER, E ;
COSOFRET, VV ;
KUSY, RP ;
BUCK, RP ;
ROSATZIN, T ;
SCHALLER, U ;
SIMON, W ;
JENEY, J ;
TOTH, K ;
PUNGOR, E .
TALANTA, 1993, 40 (07) :957-967
[27]   ELECTRICAL AND DYNAMIC PROPERTIES OF NON-PLASTICIZED POTASSIUM SELECTIVE MEMBRANES [J].
LINDNER, E ;
NIEGREISZ, Z ;
TOTH, K ;
PUNGOR, E ;
BERUBE, TR ;
BUCK, RP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 259 (1-2) :67-80
[28]  
LINDNER E, UNPUB
[29]  
Morf W.E., 1981, The principles of ion-selective electrodes and of membrane transport. M. W.E, V2
[30]   CATION-RESPONSE MECHANISM OF NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE MEMBRANES [J].
MORF, WE ;
SIMON, W .
HELVETICA CHIMICA ACTA, 1986, 69 (05) :1120-1131